Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1610.06891 · Optica

Phase sensing beyond the standard quantum limit with a variation on the SU(1,1) interferometer

Brian E. Anderson, Prasoon Gupta, Bonnie L. Schmittberger, Travis Horrom, Carla Hermann-Avigliano, K. M. Jones, Paul D. Lett

Published Jun 30, 2017• 168 citations
arXivHTMLPDF

Abstract

An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel variation in which the second nonlinear interaction is replaced with balanced homodyne detection. The phase-sensing quantum state is a two-mode squeezed state produced by seeded four-wave-mixing in Rb vapor. Measurements as a function of operating point show that even with $\approx35~\%$ loss this device can surpass the standard quantum limit by 4~dB.

DOI
10.1364/optica.4.000752

Related papers

Phase sensing beyond standard quantum limit with a truncated SU(1,1) interferometer

P. Gupta, Brian E. Anderson, Bonnie L. Schmittberger +4 more

We present an SU(1,1) interferometer variation where the second nonlinear interaction is replaced with homodyne detection. Sensitivity measurements as a function of phase demonstrate that our device beats the standard quantum limit by 4dB.

Conference on Lasers and Electro-Optics•Jan 1, 2017•0 citations

PHASE MEASUREMENTS WITH A TWO-MODE SQUEEZED STATE OF LIGHT.

Gupta, Prasoon

Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.

•Jan 1, 2019•0 citations

SU(1,1) interferometry via four-wave mixing in Rb

Travis Horrom, Brian E. Anderson, Prasoon Gupta +1 more

Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].

•Jan 1, 2015•3 citations

Phase estimation of an SU(1,1) interferometer with superposition of even and odd coherent states

Abdelmajid El Maaroufi, Mouad Ait Maskour, Bouchra Maroufi +1 more

Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.

Physica Scripta•Feb 25, 2026•0 citations

Phase sensing with a truncated SU(1,1) interferometer

P. Gupta, Brian E. Anderson, Bonnie L. Schmittberger +4 more

We present an SU(1,1) interferometer variation by replacing the second nonlinear interaction with the homodyne detection and demonstrate an improvement in phase sensitivity over the standard quantum limit.

Frontiers in Optics•Jan 1, 2017•1 citation

Optimized phase sensing in a truncated SU(1,1) interferometer

Prasoon Gupta, Bonnie L. Schmittberger, Brian E. Anderson +2 more

Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.

arXiv:1802.04314•Optics Express•Jan 4, 2018•55 citations
An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel variation in which the second nonlinear interaction is replaced with balanced homodyne detection. The phase-sensing quantum state is a two-mode squeezed state produced by seeded four-wave-mixing in Rb vapor. Measurements as a function of operating point show that even with ≈35 %\approx35~\%≈35 % loss this device can surpass the standard quantum limit by 4~dB.
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.
Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.