Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1802.04314 · Optics Express

Optimized phase sensing in a truncated SU(1,1) interferometer

Prasoon Gupta, Bonnie L. Schmittberger, Brian E. Anderson, K. M. Jones, Paul D. Lett

Published Jan 4, 2018• 55 citations
arXivHTMLPDF

Abstract

Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.

DOI
10.1364/oe.26.000391

Related papers

PHASE MEASUREMENTS WITH A TWO-MODE SQUEEZED STATE OF LIGHT.

Gupta, Prasoon

Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.

•Jan 1, 2019•0 citations

Phase sensitivity of a lossy truncated SU(1,1) interferometer with double-port homodyne detection

Yu-Wei 煜伟 Xiao 肖, Yue Ji, Jun Wei +2 more

Abstract We theoretically investigate the phase sensitivity of a truncated SU(1,1) interferometer fed with a two-mode coherent state and employing double-port homodyne detection. On the one hand, we analytically demonstrate that the two-mode coherent state provides better phase sensitivity than the single-mode coherent state. In addition, we show that the double-port homodyne detection is a quasi-optimal measurement. For a bright coherent-state input, the sensitivity of this scheme saturates the phase-sensitivity bound determined by the quantum Fisher information. On the other hand, we quantitatively illustrate the advantage of double-port homodyne detection over the single-port scheme under ideal conditions and in the presence of photon loss, respectively. Furthermore, our analysis indicates that the scheme we propose is robust against photon loss.

Chinese Physics B•Aug 20, 2025•1 citation

The Super Phase Sensitivity of an SU(1,1) Interferometer with a Two-Mode Squeezed Coherent State via Balanced Homodyne and Intensity Detection

Changlan Xu, Lei Wang, Shaoqiu Ke +2 more

We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.

Photonics•Mar 23, 2026•0 citations

Sensitivity Evaluation of SU(1,1) Interferometers with Arbitrary Input Probe State and Homodyne Detections

Sonu Jana, Dhruv Baheti, Paul Grossiord +3 more

We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous $|α,0\rangle$ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.

quant-pharXiv:2605.22029•May 22, 2026•0 citations

Optimal phase measurements with bright- and vacuum-seeded SU(1,1) interferometers

Brian E. Anderson, Bonnie L. Schmittberger, Prasoon Gupta +2 more

The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beam splitters replaced with parametric nonlinear optical processes. We consider the cases of bright- and vacuum-seeded SU(1,1) interferometers using intensity or homodyne detectors. A simplified truncated scheme with only one nonlinear interaction is introduced, which not only beats conventional intensity detection with a bright seed, but can saturate the phase-sensitivity bound set by the quantum Fisher information. We also show that the truncated scheme achieves a sub-shot-noise phase sensitivity in the vacuum-seeded case, despite the phase-sensing optical beams having no well-defined phase.

arXiv:1704.04261•Physical Review A•Jun 27, 2017•86 citations

Phase estimation of an SU(1,1) interferometer with superposition of even and odd coherent states

Abdelmajid El Maaroufi, Mouad Ait Maskour, Bouchra Maroufi +1 more

Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.

Physica Scripta•Feb 25, 2026•0 citations
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.
Abstract We theoretically investigate the phase sensitivity of a truncated SU(1,1) interferometer fed with a two-mode coherent state and employing double-port homodyne detection. On the one hand, we analytically demonstrate that the two-mode coherent state provides better phase sensitivity than the single-mode coherent state. In addition, we show that the double-port homodyne detection is a quasi-optimal measurement. For a bright coherent-state input, the sensitivity of this scheme saturates the phase-sensitivity bound determined by the quantum Fisher information. On the other hand, we quantitatively illustrate the advantage of double-port homodyne detection over the single-port scheme under ideal conditions and in the presence of photon loss, respectively. Furthermore, our analysis indicates that the scheme we propose is robust against photon loss.
We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous ∣α,0⟩|α,0\rangle∣α,0⟩ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.
The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beam splitters replaced with parametric nonlinear optical processes. We consider the cases of bright- and vacuum-seeded SU(1,1) interferometers using intensity or homodyne detectors. A simplified truncated scheme with only one nonlinear interaction is introduced, which not only beats conventional intensity detection with a bright seed, but can saturate the phase-sensitivity bound set by the quantum Fisher information. We also show that the truncated scheme achieves a sub-shot-noise phase sensitivity in the vacuum-seeded case, despite the phase-sensing optical beams having no well-defined phase.
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.