Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Low noise measurement method based on differential optical interferometer for cold atom experiments

Xiao-Xiao Ma, Xian Zhang, Kaikai Huang, Xuanhui Lu

Published Dec 13, 2019• 2 citations
Publisher

Abstract

We proposed and realized a low noise measurement method based on differential optical interferometer to measure trapped cold atoms in a magneto-optical trap (MOT). The configuration is based on a Mach-Zehnder type interferometer, which is composed of two beams of different frequencies. A long-term stability in phase monitor has been obtained by use of the vibration immune mechanism through subtraction of the interferograms imaged on the two photodetectors. With this new configuration, the noise caused by environmental perturbation is greatly reduced at low frequency while the signal of phase shift keeps a good long-term stability.

DOI
10.1364/oe.381560

Related papers

Noise-suppressing and lock-free optical interferometer for cold atom experiments

Xiao-Xiao Ma, Xian Zhang, Kaikai Huang +1 more

A novel noise-suppressing and lock-free interferometer is proposed and experimentally demonstrated in the study of the quantum non-destructive (QND) interaction of cold atoms. A QND measurement based on far-off resonant dispersive probing is usually carried out by a Mach-Zehnder type interferometer. It is an experimental challenge in its own right to reduce the classical noise, such as acoustic noise, phase noise and amplitude noise of lasers, and to lock the interferometer at the white-light position that corresponds to a nearly zero path-length difference. Here, we report an interferometer with an inserted acousto-optic modulator (AOM). It is noise immune and lock-free in principle. The experiments show that the new interferometer is able to measure cold atoms for more than 30 minutes and reduce the phase noise by about 30 dB.

Optics Express•Aug 28, 2020•2 citations

Measurement of audio signal by using low-frequency squeezed light

Yan Zi-Hua, Sun Heng-Xin, Cai Chun-Xiao +3 more

Measurement of audio signal plays a significant role in many applications, such as gravitational wave detection, bio-particle imaging and magnetometer. In this paper, low-frequency squeezed light is generated by a non-degenerate optical parametric amplifier. In order to avoid the effect of injected light on low-frequency squeezing, an auxiliary laser is used to lock the length of non-degenerate optical parametric amplifier and a method of locking quantum noise is employed to lock the phase between the local light and the squeezed light. By isolating the vibration noises at low-frequency and reducing back action of parasitic interference, the squeezing of (7.1±0.1) dB takes place at 19 kHz. Then the squeezed light is injected into the Mach-Zehnder interferometer to measure an audio signal which drives a piezoelectric transducer to generate a small phase variation between two arms of Mach-Zehnder interferometer. According to the low-frequency squeezing, we realize experimentally the measurement of phase signal at audio frequency which exceeds the shot-noise limit of (3.0±0.4) dB. The experiment provides technical supports for the generation of low-frequency squeezed light and the measurement of audio signal. Furthermore it can be extended to other quantum measurements, such as high-precision magnetometer and measurement of small-displacement.

Acta Physica Sinica•Jan 1, 2017•4 citations

Atomic spin precession detection method based on the Mach-Zehnder interferometer in an atomic comagnetometer

Weijia Zhang, Lihong Duan, Wenfeng Fan +1 more

A new method for the detection of atomic spin precession based on the Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. Different from the conventional polarization detection methods which obtain the atomic spin precession signal by measuring the change of the probe laser power, the proposed method uses the laser modulated by an electro-optic phase modulator (EOM) as the source of the interferometer, and obtains the atomic spin precession signal by measuring the phase difference between the two arms of the MZI. The output of interferometer is independent of the probe laser power, which avoids the system error caused by the fluctuation of the probe laser power, and the long-term stability of the system is effectively improved. At the same time, the method adopts high-frequency electro-optic modulation, which can effectively suppress low-frequency noise, such as 1/f noise, and can significantly improve the detection sensitivity. The rotation sensitivity and long-term stability of the atomic comagnetometer were tested using the MZI detection method and a typical detection method, respectively. The comparison results show that the proposed method has the highest low frequency sensitivity and the potential to improve the long-term stability of the system.

Optics Express•Dec 6, 2022•6 citations

Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams

Zhi-Xin Meng, Pei-Qiang Yan, Shengzhe Wang +3 more

We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two ${\text{2D}}^{+}$ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of $6.1\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\text{g}$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area $A=0.097\phantom{\rule{0.2em}{0ex}}{\text{mm}}^{2}$). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.

arXiv:2210.15346•Physical Review Applied•Mar 22, 2024•21 citations

Method for the differential measurement of phase shifts induced by atoms in an optical ring cavity

Enlong Wang, Gunjan Verma, Jonathan N. Tinsley +2 more

We demonstrate a method of light phase shift measurement using a high-finesse optical ring cavity which exhibits reduced phase noise due to cavity length fluctuations. Two laser beams with a frequency difference of one cavity free spectral range are simultaneously resonant with the cavity, demonstrating noise correlations in the error signals due to the common-mode cavity length fluctuations. The differential error signal shows a 30 dB reduction in cavity noise down to the noise floor in a frequency range up to half the cavity linewidth ($\ensuremath{\delta}\ensuremath{\nu}/2\ensuremath{\simeq}30$ kHz). Various noise sources are analyzed and their contributions to the noise floor are evaluated. Additionally, we apply this noise-reduced phase shift measurement scheme in a simulated spin-squeezing experiment where we have achieved a factor of 40 improvement in phase sensitivity with a phase resolution of 0.7 mrad, which may remove one important barrier against attaining highly spin-squeezed states. The demonstrated method provides a flexible situation by using an optical ring cavity and two independent beams. This method can find direct application to nondestructive measurements in quantum systems, such as for the generation of spin-squeezed states in atom interferometers and atomic clocks.

arXiv:2009.05006•Physical Review A•Feb 16, 2021•6 citations

Real-time compensation scheme for the accurate measurement of the differential phase in a dual-atom-interferometer gyroscope

Ze-Xi Lu, Zhan-Wei Yao, Honghui Chen +10 more

A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.

Physical Review A•Mar 10, 2025•2 citations
We proposed and realized a low noise measurement method based on differential optical interferometer to measure trapped cold atoms in a magneto-optical trap (MOT). The configuration is based on a Mach-Zehnder type interferometer, which is composed of two beams of different frequencies. A long-term stability in phase monitor has been obtained by use of the vibration immune mechanism through subtraction of the interferograms imaged on the two photodetectors. With this new configuration, the noise caused by environmental perturbation is greatly reduced at low frequency while the signal of phase shift keeps a good long-term stability.
A novel noise-suppressing and lock-free interferometer is proposed and experimentally demonstrated in the study of the quantum non-destructive (QND) interaction of cold atoms. A QND measurement based on far-off resonant dispersive probing is usually carried out by a Mach-Zehnder type interferometer. It is an experimental challenge in its own right to reduce the classical noise, such as acoustic noise, phase noise and amplitude noise of lasers, and to lock the interferometer at the white-light position that corresponds to a nearly zero path-length difference. Here, we report an interferometer with an inserted acousto-optic modulator (AOM). It is noise immune and lock-free in principle. The experiments show that the new interferometer is able to measure cold atoms for more than 30 minutes and reduce the phase noise by about 30 dB.
Measurement of audio signal plays a significant role in many applications, such as gravitational wave detection, bio-particle imaging and magnetometer. In this paper, low-frequency squeezed light is generated by a non-degenerate optical parametric amplifier. In order to avoid the effect of injected light on low-frequency squeezing, an auxiliary laser is used to lock the length of non-degenerate optical parametric amplifier and a method of locking quantum noise is employed to lock the phase between the local light and the squeezed light. By isolating the vibration noises at low-frequency and reducing back action of parasitic interference, the squeezing of (7.1±0.1) dB takes place at 19 kHz. Then the squeezed light is injected into the Mach-Zehnder interferometer to measure an audio signal which drives a piezoelectric transducer to generate a small phase variation between two arms of Mach-Zehnder interferometer. According to the low-frequency squeezing, we realize experimentally the measurement of phase signal at audio frequency which exceeds the shot-noise limit of (3.0±0.4) dB. The experiment provides technical supports for the generation of low-frequency squeezed light and the measurement of audio signal. Furthermore it can be extended to other quantum measurements, such as high-precision magnetometer and measurement of small-displacement.
A new method for the detection of atomic spin precession based on the Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. Different from the conventional polarization detection methods which obtain the atomic spin precession signal by measuring the change of the probe laser power, the proposed method uses the laser modulated by an electro-optic phase modulator (EOM) as the source of the interferometer, and obtains the atomic spin precession signal by measuring the phase difference between the two arms of the MZI. The output of interferometer is independent of the probe laser power, which avoids the system error caused by the fluctuation of the probe laser power, and the long-term stability of the system is effectively improved. At the same time, the method adopts high-frequency electro-optic modulation, which can effectively suppress low-frequency noise, such as 1/f noise, and can significantly improve the detection sensitivity. The rotation sensitivity and long-term stability of the atomic comagnetometer were tested using the MZI detection method and a typical detection method, respectively. The comparison results show that the proposed method has the highest low frequency sensitivity and the potential to improve the long-term stability of the system.
We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two 2D+{\text{2D}}^{+}2D+ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of $6.1\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\text{g}$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area A=0.097mm2A=0.097\phantom{\rule{0.2em}{0ex}}{\text{mm}}^{2}A=0.097mm2). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.
We demonstrate a method of light phase shift measurement using a high-finesse optical ring cavity which exhibits reduced phase noise due to cavity length fluctuations. Two laser beams with a frequency difference of one cavity free spectral range are simultaneously resonant with the cavity, demonstrating noise correlations in the error signals due to the common-mode cavity length fluctuations. The differential error signal shows a 30 dB reduction in cavity noise down to the noise floor in a frequency range up to half the cavity linewidth ($\ensuremath{\delta}\ensuremath{\nu}/2\ensuremath{\simeq}30$ kHz). Various noise sources are analyzed and their contributions to the noise floor are evaluated. Additionally, we apply this noise-reduced phase shift measurement scheme in a simulated spin-squeezing experiment where we have achieved a factor of 40 improvement in phase sensitivity with a phase resolution of 0.7 mrad, which may remove one important barrier against attaining highly spin-squeezed states. The demonstrated method provides a flexible situation by using an optical ring cavity and two independent beams. This method can find direct application to nondestructive measurements in quantum systems, such as for the generation of spin-squeezed states in atom interferometers and atomic clocks.
A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.