Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Measurement of audio signal by using low-frequency squeezed light

Yan Zi-Hua, Sun Heng-Xin, Cai Chun-Xiao, Long Ma, Liu Kui, Gao Jiang-Rui

Published Jan 1, 2017• 4 citations
Publisher

Abstract

Measurement of audio signal plays a significant role in many applications, such as gravitational wave detection, bio-particle imaging and magnetometer. In this paper, low-frequency squeezed light is generated by a non-degenerate optical parametric amplifier. In order to avoid the effect of injected light on low-frequency squeezing, an auxiliary laser is used to lock the length of non-degenerate optical parametric amplifier and a method of locking quantum noise is employed to lock the phase between the local light and the squeezed light. By isolating the vibration noises at low-frequency and reducing back action of parasitic interference, the squeezing of (7.1±0.1) dB takes place at 19 kHz. Then the squeezed light is injected into the Mach-Zehnder interferometer to measure an audio signal which drives a piezoelectric transducer to generate a small phase variation between two arms of Mach-Zehnder interferometer. According to the low-frequency squeezing, we realize experimentally the measurement of phase signal at audio frequency which exceeds the shot-noise limit of (3.0±0.4) dB. The experiment provides technical supports for the generation of low-frequency squeezed light and the measurement of audio signal. Furthermore it can be extended to other quantum measurements, such as high-precision magnetometer and measurement of small-displacement.

DOI
10.7498/aps.66.114205

Related papers

Measurement of low-frequency signal based on quantum-enhanced fiber Mach-Zehnder interferometer

Cheng Jian, Feng Jin-Xia, Yuanji Li +1 more

Generation of squeezed state at telecommunication wavelength has been recently a very interesting issue due to the lowest optical power attenuation of light at a wavelength of 1550 nm in a standard telecommunication fiber. The low-frequency vacuum squeezed state at 1550 nm in combination with fiber based interferometer offers the possibility to implement quantum precision measurement beyond standard quantum limit (SQL). In this paper, we experimentally realize a quantum-enhanced fiber Mach-Zehnder interferometer (FMZI) for measuring the low-frequency phase modulation signal by using low-frequency vacuum squeezing at 1550 nm. Firstly, the low-frequency vacuum squeezed state at the telecommunication wavelength of 1550 nm is generated by using a degenerate optical parametric oscillator (DOPO). The DOPO is a semi-monolithic construction based on a type I periodically poled KTiOPO4 (PPKTP) crystal and a concave mirror. The pump threshold of DOPO is 270 mW. When the pump power is 120 mW that is below the pump threshold of DOPO and the temperature of PPKTP is controlled at 34.8℃, a vacuum squeezing of 3 dB is generated at an analysis frequency range from 10 kHz to 500 kHz. The quadrature phase vacuum squeezing is obtained by locking the squeezed quadrature angle through using a coherent control scheme, in which two acousto-optic modulators are used to shift the frequency and produce the auxiliary beam acting as a coherent control field. Based on the constructed FMZI, a quantum-enhanced FMZI is realized by injecting the generated low-frequency vacuum squeezed state at 1550 nm into the vacuum channel of FMZI. The relative phase between two injected light fields is locked at π by using the Pound-Drever-Hall (PDH) locking technology, and the relative phase between light fields of its arms in FMZI is also locked at π/2 by using the PDH locking technology. When a phase modulation signal at the frequency of 500 kHz is loaded in the signal arm of FMZI, the noise power spectrum of the output from FMZI is measured by a balance homodyne detect system. A 2 dB quantum improvement beyond shot-noise-level at the frequency of 500 kHz is obtained experimentally by using the quantum-enhanced FMZI. The experimental results demonstrate a potential application in quantum precision measurement beyond the SQL based on fiber sensor technique.

Acta Physica Sinica•Jan 1, 2018•3 citations

Generation of audio-band frequency squeezed light at 1.34 μm

Feng Jin-Xia, 杜京师 DU Jing-shi, Jin Xiao-Li +2 more

Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.

Acta Physica Sinica•Jan 1, 2018•2 citations

Scheme for efficient extraction of low-frequency signal beyond the quantum limit by frequency-shift detection

Rongguo Yang, J. Zhang, Z. H. Zhai +3 more

Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.

Optics Express•Aug 6, 2015•6 citations

Squeezing-enhanced fiber Mach-Zehnder interferometer for low-frequency phase measurement

Fang Liu, Yaoyao Zhou, Juan Yu +7 more

We propose and experimentally demonstrate a quantum-enhanced fiber Mach-Zehnder interferometer for low-frequency phase measurement beyond the shot-noise limit using a high-frequency squeezing technique. The local oscillator field is amplitude-modulated in the MHz range and is then demodulated to avoid the technical noise that occurs at low frequencies. After measurement of the phase noise at a frequency of tens of kHz, an improvement of ∼2 dB relative to the shot-noise level is achieved. Additionally, the amplitude modulation depth has no significant effect on the phase noise improvement of the interferometer when deployed in our experimental configuration. The current scheme introduces a quantum technique into the fiber-based measurements, particularly for the low frequency range, and this scheme has potential applications in the high-precision fiber sensing of temperature, strain, and various other parameters.

Applied Physics Letters•Jan 9, 2017•34 citations

Generation of squeezed states at low analysis frequencies

Xin Wen, Yashuai Han, Liu Jin-Yu +3 more

Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.

Acta Physica Sinica•Jan 1, 2018•4 citations

Generation of low-frequency squeezed states

Liu Zeng-Jun, Zhai Ze-Hui, Sun Heng-Xin +1 more

Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.

Acta Physica Sinica•Jan 1, 2016•2 citations
Measurement of audio signal plays a significant role in many applications, such as gravitational wave detection, bio-particle imaging and magnetometer. In this paper, low-frequency squeezed light is generated by a non-degenerate optical parametric amplifier. In order to avoid the effect of injected light on low-frequency squeezing, an auxiliary laser is used to lock the length of non-degenerate optical parametric amplifier and a method of locking quantum noise is employed to lock the phase between the local light and the squeezed light. By isolating the vibration noises at low-frequency and reducing back action of parasitic interference, the squeezing of (7.1±0.1) dB takes place at 19 kHz. Then the squeezed light is injected into the Mach-Zehnder interferometer to measure an audio signal which drives a piezoelectric transducer to generate a small phase variation between two arms of Mach-Zehnder interferometer. According to the low-frequency squeezing, we realize experimentally the measurement of phase signal at audio frequency which exceeds the shot-noise limit of (3.0±0.4) dB. The experiment provides technical supports for the generation of low-frequency squeezed light and the measurement of audio signal. Furthermore it can be extended to other quantum measurements, such as high-precision magnetometer and measurement of small-displacement.
Generation of squeezed state at telecommunication wavelength has been recently a very interesting issue due to the lowest optical power attenuation of light at a wavelength of 1550 nm in a standard telecommunication fiber. The low-frequency vacuum squeezed state at 1550 nm in combination with fiber based interferometer offers the possibility to implement quantum precision measurement beyond standard quantum limit (SQL). In this paper, we experimentally realize a quantum-enhanced fiber Mach-Zehnder interferometer (FMZI) for measuring the low-frequency phase modulation signal by using low-frequency vacuum squeezing at 1550 nm. Firstly, the low-frequency vacuum squeezed state at the telecommunication wavelength of 1550 nm is generated by using a degenerate optical parametric oscillator (DOPO). The DOPO is a semi-monolithic construction based on a type I periodically poled KTiOPO4 (PPKTP) crystal and a concave mirror. The pump threshold of DOPO is 270 mW. When the pump power is 120 mW that is below the pump threshold of DOPO and the temperature of PPKTP is controlled at 34.8℃, a vacuum squeezing of 3 dB is generated at an analysis frequency range from 10 kHz to 500 kHz. The quadrature phase vacuum squeezing is obtained by locking the squeezed quadrature angle through using a coherent control scheme, in which two acousto-optic modulators are used to shift the frequency and produce the auxiliary beam acting as a coherent control field. Based on the constructed FMZI, a quantum-enhanced FMZI is realized by injecting the generated low-frequency vacuum squeezed state at 1550 nm into the vacuum channel of FMZI. The relative phase between two injected light fields is locked at π by using the Pound-Drever-Hall (PDH) locking technology, and the relative phase between light fields of its arms in FMZI is also locked at π/2 by using the PDH locking technology. When a phase modulation signal at the frequency of 500 kHz is loaded in the signal arm of FMZI, the noise power spectrum of the output from FMZI is measured by a balance homodyne detect system. A 2 dB quantum improvement beyond shot-noise-level at the frequency of 500 kHz is obtained experimentally by using the quantum-enhanced FMZI. The experimental results demonstrate a potential application in quantum precision measurement beyond the SQL based on fiber sensor technique.
Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.
Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.
We propose and experimentally demonstrate a quantum-enhanced fiber Mach-Zehnder interferometer for low-frequency phase measurement beyond the shot-noise limit using a high-frequency squeezing technique. The local oscillator field is amplitude-modulated in the MHz range and is then demodulated to avoid the technical noise that occurs at low frequencies. After measurement of the phase noise at a frequency of tens of kHz, an improvement of ∼2 dB relative to the shot-noise level is achieved. Additionally, the amplitude modulation depth has no significant effect on the phase noise improvement of the interferometer when deployed in our experimental configuration. The current scheme introduces a quantum technique into the fiber-based measurements, particularly for the low frequency range, and this scheme has potential applications in the high-precision fiber sensing of temperature, strain, and various other parameters.
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.
Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.