Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Squeezing-enhanced fiber Mach-Zehnder interferometer for low-frequency phase measurement

Fang Liu, Yaoyao Zhou, Juan Yu, Jiale Guo, Yang Wu, Shixiong Xiao, Dan Wei, Yong Zhang, Xiaojun Jia, Min Xiao

Published Jan 9, 2017• 34 citations
Publisher

Abstract

We propose and experimentally demonstrate a quantum-enhanced fiber Mach-Zehnder interferometer for low-frequency phase measurement beyond the shot-noise limit using a high-frequency squeezing technique. The local oscillator field is amplitude-modulated in the MHz range and is then demodulated to avoid the technical noise that occurs at low frequencies. After measurement of the phase noise at a frequency of tens of kHz, an improvement of ∼2 dB relative to the shot-noise level is achieved. Additionally, the amplitude modulation depth has no significant effect on the phase noise improvement of the interferometer when deployed in our experimental configuration. The current scheme introduces a quantum technique into the fiber-based measurements, particularly for the low frequency range, and this scheme has potential applications in the high-precision fiber sensing of temperature, strain, and various other parameters.

DOI
10.1063/1.4973895

Related papers

Quantum-enhanced optical precision measurement assisted by low-frequency squeezed vacuum states

Guohui 国辉 Kang 康, Jinxia 晋霞 Feng 冯, Lin 琳 Cheng 程 +2 more

Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated. By controlling the squeezing angle of the squeezed vacuum states, two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively. A quantum-enhanced fiber Mach–Zehnder interferometer (FMZI) was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected. When phase modulation was measured with the quantum-enhanced FMZI, there were above 3 dB quantum improvements beyond the shot-noise limit (SNL) from 40 kHz to 200 kHz, and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained. The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction. There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz. The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber, particularly in the low-frequency range.

Chinese Physics B•Mar 17, 2023•4 citations

Measurement of low-frequency signal based on quantum-enhanced fiber Mach-Zehnder interferometer

Cheng Jian, Feng Jin-Xia, Yuanji Li +1 more

Generation of squeezed state at telecommunication wavelength has been recently a very interesting issue due to the lowest optical power attenuation of light at a wavelength of 1550 nm in a standard telecommunication fiber. The low-frequency vacuum squeezed state at 1550 nm in combination with fiber based interferometer offers the possibility to implement quantum precision measurement beyond standard quantum limit (SQL). In this paper, we experimentally realize a quantum-enhanced fiber Mach-Zehnder interferometer (FMZI) for measuring the low-frequency phase modulation signal by using low-frequency vacuum squeezing at 1550 nm. Firstly, the low-frequency vacuum squeezed state at the telecommunication wavelength of 1550 nm is generated by using a degenerate optical parametric oscillator (DOPO). The DOPO is a semi-monolithic construction based on a type I periodically poled KTiOPO4 (PPKTP) crystal and a concave mirror. The pump threshold of DOPO is 270 mW. When the pump power is 120 mW that is below the pump threshold of DOPO and the temperature of PPKTP is controlled at 34.8℃, a vacuum squeezing of 3 dB is generated at an analysis frequency range from 10 kHz to 500 kHz. The quadrature phase vacuum squeezing is obtained by locking the squeezed quadrature angle through using a coherent control scheme, in which two acousto-optic modulators are used to shift the frequency and produce the auxiliary beam acting as a coherent control field. Based on the constructed FMZI, a quantum-enhanced FMZI is realized by injecting the generated low-frequency vacuum squeezed state at 1550 nm into the vacuum channel of FMZI. The relative phase between two injected light fields is locked at π by using the Pound-Drever-Hall (PDH) locking technology, and the relative phase between light fields of its arms in FMZI is also locked at π/2 by using the PDH locking technology. When a phase modulation signal at the frequency of 500 kHz is loaded in the signal arm of FMZI, the noise power spectrum of the output from FMZI is measured by a balance homodyne detect system. A 2 dB quantum improvement beyond shot-noise-level at the frequency of 500 kHz is obtained experimentally by using the quantum-enhanced FMZI. The experimental results demonstrate a potential application in quantum precision measurement beyond the SQL based on fiber sensor technique.

Acta Physica Sinica•Jan 1, 2018•3 citations

Measurement of audio signal by using low-frequency squeezed light

Yan Zi-Hua, Sun Heng-Xin, Cai Chun-Xiao +3 more

Measurement of audio signal plays a significant role in many applications, such as gravitational wave detection, bio-particle imaging and magnetometer. In this paper, low-frequency squeezed light is generated by a non-degenerate optical parametric amplifier. In order to avoid the effect of injected light on low-frequency squeezing, an auxiliary laser is used to lock the length of non-degenerate optical parametric amplifier and a method of locking quantum noise is employed to lock the phase between the local light and the squeezed light. By isolating the vibration noises at low-frequency and reducing back action of parasitic interference, the squeezing of (7.1±0.1) dB takes place at 19 kHz. Then the squeezed light is injected into the Mach-Zehnder interferometer to measure an audio signal which drives a piezoelectric transducer to generate a small phase variation between two arms of Mach-Zehnder interferometer. According to the low-frequency squeezing, we realize experimentally the measurement of phase signal at audio frequency which exceeds the shot-noise limit of (3.0±0.4) dB. The experiment provides technical supports for the generation of low-frequency squeezed light and the measurement of audio signal. Furthermore it can be extended to other quantum measurements, such as high-precision magnetometer and measurement of small-displacement.

Acta Physica Sinica•Jan 1, 2017•4 citations

Entanglement-enhanced phase sensitivity at low frequencies in a truncated SU(1,1) interferometer

Jin Yan, Shaohui Hong, Wenjing Zhao +7 more

Quantum metrology harnesses nonclassical resources including squeezed states and quantum entanglement to overcome fundamental limitations imposed by the shot-noise limit (SNL). While conventional optical interferometers for phase detection typically operate in the MHz-frequency regime due to technical noise constraints at lower frequencies, numerous practical applications demand operation in the kHz regime or below. Here, we present a truncated SU(1,1) interferometric configuration that achieves enhanced phase sensitivity in the low-frequency (kHz) domain by exploiting quantum entanglement generated through two-mode squeezed states. Our approach incorporates quantum sideband control to achieve quantum correlations across multiple low-frequency bands while simultaneously suppressing technical noise. Through precise locking of optimal phase, we demonstrate a significant improvement in signal-to-noise ratio within the kHz range, with phase sensitivity surpassing the SNL by 2.0 ± 0.2 dB. These experimental results provide crucial validation for extending entanglement-enhanced optical interferometry into low-frequency metrological applications and establish novel methodologies for optical modulation and sideband-based quantum information processing and quantum sensing protocols.

Optics Letters•Jun 17, 2025•1 citation

Subhertz interferometry at the quantum noise limit

Peng Yang, Boya Xie, Sheng Feng

Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.

Optics Letters•Apr 29, 2019•12 citations

Scheme for efficient extraction of low-frequency signal beyond the quantum limit by frequency-shift detection

Rongguo Yang, J. Zhang, Z. H. Zhai +3 more

Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.

Optics Express•Aug 6, 2015•6 citations
We propose and experimentally demonstrate a quantum-enhanced fiber Mach-Zehnder interferometer for low-frequency phase measurement beyond the shot-noise limit using a high-frequency squeezing technique. The local oscillator field is amplitude-modulated in the MHz range and is then demodulated to avoid the technical noise that occurs at low frequencies. After measurement of the phase noise at a frequency of tens of kHz, an improvement of ∼2 dB relative to the shot-noise level is achieved. Additionally, the amplitude modulation depth has no significant effect on the phase noise improvement of the interferometer when deployed in our experimental configuration. The current scheme introduces a quantum technique into the fiber-based measurements, particularly for the low frequency range, and this scheme has potential applications in the high-precision fiber sensing of temperature, strain, and various other parameters.
Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated. By controlling the squeezing angle of the squeezed vacuum states, two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively. A quantum-enhanced fiber Mach–Zehnder interferometer (FMZI) was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected. When phase modulation was measured with the quantum-enhanced FMZI, there were above 3 dB quantum improvements beyond the shot-noise limit (SNL) from 40 kHz to 200 kHz, and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained. The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction. There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz. The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber, particularly in the low-frequency range.
Generation of squeezed state at telecommunication wavelength has been recently a very interesting issue due to the lowest optical power attenuation of light at a wavelength of 1550 nm in a standard telecommunication fiber. The low-frequency vacuum squeezed state at 1550 nm in combination with fiber based interferometer offers the possibility to implement quantum precision measurement beyond standard quantum limit (SQL). In this paper, we experimentally realize a quantum-enhanced fiber Mach-Zehnder interferometer (FMZI) for measuring the low-frequency phase modulation signal by using low-frequency vacuum squeezing at 1550 nm. Firstly, the low-frequency vacuum squeezed state at the telecommunication wavelength of 1550 nm is generated by using a degenerate optical parametric oscillator (DOPO). The DOPO is a semi-monolithic construction based on a type I periodically poled KTiOPO4 (PPKTP) crystal and a concave mirror. The pump threshold of DOPO is 270 mW. When the pump power is 120 mW that is below the pump threshold of DOPO and the temperature of PPKTP is controlled at 34.8℃, a vacuum squeezing of 3 dB is generated at an analysis frequency range from 10 kHz to 500 kHz. The quadrature phase vacuum squeezing is obtained by locking the squeezed quadrature angle through using a coherent control scheme, in which two acousto-optic modulators are used to shift the frequency and produce the auxiliary beam acting as a coherent control field. Based on the constructed FMZI, a quantum-enhanced FMZI is realized by injecting the generated low-frequency vacuum squeezed state at 1550 nm into the vacuum channel of FMZI. The relative phase between two injected light fields is locked at π by using the Pound-Drever-Hall (PDH) locking technology, and the relative phase between light fields of its arms in FMZI is also locked at π/2 by using the PDH locking technology. When a phase modulation signal at the frequency of 500 kHz is loaded in the signal arm of FMZI, the noise power spectrum of the output from FMZI is measured by a balance homodyne detect system. A 2 dB quantum improvement beyond shot-noise-level at the frequency of 500 kHz is obtained experimentally by using the quantum-enhanced FMZI. The experimental results demonstrate a potential application in quantum precision measurement beyond the SQL based on fiber sensor technique.
Measurement of audio signal plays a significant role in many applications, such as gravitational wave detection, bio-particle imaging and magnetometer. In this paper, low-frequency squeezed light is generated by a non-degenerate optical parametric amplifier. In order to avoid the effect of injected light on low-frequency squeezing, an auxiliary laser is used to lock the length of non-degenerate optical parametric amplifier and a method of locking quantum noise is employed to lock the phase between the local light and the squeezed light. By isolating the vibration noises at low-frequency and reducing back action of parasitic interference, the squeezing of (7.1±0.1) dB takes place at 19 kHz. Then the squeezed light is injected into the Mach-Zehnder interferometer to measure an audio signal which drives a piezoelectric transducer to generate a small phase variation between two arms of Mach-Zehnder interferometer. According to the low-frequency squeezing, we realize experimentally the measurement of phase signal at audio frequency which exceeds the shot-noise limit of (3.0±0.4) dB. The experiment provides technical supports for the generation of low-frequency squeezed light and the measurement of audio signal. Furthermore it can be extended to other quantum measurements, such as high-precision magnetometer and measurement of small-displacement.
Quantum metrology harnesses nonclassical resources including squeezed states and quantum entanglement to overcome fundamental limitations imposed by the shot-noise limit (SNL). While conventional optical interferometers for phase detection typically operate in the MHz-frequency regime due to technical noise constraints at lower frequencies, numerous practical applications demand operation in the kHz regime or below. Here, we present a truncated SU(1,1) interferometric configuration that achieves enhanced phase sensitivity in the low-frequency (kHz) domain by exploiting quantum entanglement generated through two-mode squeezed states. Our approach incorporates quantum sideband control to achieve quantum correlations across multiple low-frequency bands while simultaneously suppressing technical noise. Through precise locking of optimal phase, we demonstrate a significant improvement in signal-to-noise ratio within the kHz range, with phase sensitivity surpassing the SNL by 2.0 ± 0.2 dB. These experimental results provide crucial validation for extending entanglement-enhanced optical interferometry into low-frequency metrological applications and establish novel methodologies for optical modulation and sideband-based quantum information processing and quantum sensing protocols.
Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.
Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.