Quantum Electronics

On the possibility of a significant improvement in the quality of a quantum ghost image by registering an additional image in the object channel

Dmitriy A. Balakin, Aleksandr V. Belinsky

Published Oct 1, 2019• 9 citations
Publisher

Abstract

Abstract A modification of the classical scheme of the quantum ghost image formation is considered, in which an image of the object under study is formed and recorded in the object channel. This image is used together with the ghost image to construct an estimate of the transparency distribution of the object. It is shown that this technique reduces the image quality worsening associated with the non-unit quantum efficiency of the sensors, even when the quantum image obtained in the object channel is additionally distorted by noise due to photons that did not interact with the object.

DOI
10.1070/qel17039

Related papers

Mathematical Processing of Quantum Images in a Biphoton Setup via Measurement Reduction

Dmitriy A. Balakin, Aleksandr V. Belinsky

Abstract We investigate the possibilities of increasing the measurement accuracy and creating the least-damaging regime of object illumination by mathematical simulation of the process of generating paired images, that is, a ghost image and a regular image, using a new scheme with quantum biphoton generation. It is shown that diffraction and non-unit quantum efficiency of the sensors in traditional ghost imaging cause missing some information carried by the object arm photons. Forming an image of the studied object in the object arm and registering it makes it possible to weaken the influence of these factors on the measurement result when using the developed version of the method of measurement reduction to the form that is typical for measuring the transparency distribution of the object for processing a pair of obtained images.

Moscow University Physics Bulletin•Jul 1, 2020•6 citations

Reduction of Multiplexed Quantum Ghost Images

Dmitriy A. Balakin, Aleksandr V. Belinsky

Ghost imaging allows extracting information about an object from the spatial correlation function between the photons that interacted with an object and the photons in the reference arm(s). The reference beam does not interact with the object; however, it is measured by a CCD matrix. The mathematical method of measurement reduction allows using both the mutual correlations of multiplexed ghost images and prior information about how the image of the research object can look in order to improve the quality of the reconstructed image. The information about the object is the sparsity of its transparency distribution under a given transform. Computer modelling of image reconstruction using multiplexed ghost images formed by four-mode entangled quantum light states confirms the efficiency of the proposed algorithm even with a small number of photons that illuminate the research object.

Moscow University Physics Bulletin•Jan 1, 2019•4 citations

Ghost Imaging with Non-Gaussian Quantum Light

Dongyu Liu, Mingsheng Tian, Shuheng Liu +5 more

Nonlocal point-to-point correlations between two photons have been used to produce ``ghost'' images without placing the camera towards the object. Here we theoretically demonstrate and analyze the advantage of non-Gaussian quantum light in improving the image quality of a ghost imaging system over a traditional Gaussian light source. For any squeezing degree, the signal-to-noise ratio (SNR) of the ghost image can be enhanced by the non-Gaussian operations of photon addition and subtraction on a two-mode squeezed light source. We find striking evidence that using non-Gaussian coherent operations, the SNR can be promoted to a high level even within the extremely weak squeezing regime. The resulting insight provides experimental recipes of quantum imaging using non-Gaussian light for illumination.

arXiv:2106.00443•Physical Review Applied•Dec 15, 2021•16 citations

Ghost images without the background based on Bell states

A. S. Chirkin

When observing a ghost image, information on an object is obtained by measuring the spatial correlation between photons propagating in the object and reconstruction channels. In the traditional schemes involving two-mode entangled quantum states or quasithermal light sources, the correlation function of photons has a background associated with the average number of photons in the channels. It has been shown in this work that the use of polarization-entangled states, e.g., Bell states, allows removing this background and, thereby, obtaining a higher quality reconstructed image.

Journal of Experimental and Theoretical Physics Letters•Feb 1, 2016•7 citations

Quantum ghost imaging

Morris, Peter A.

The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.

•Jan 1, 2018•0 citations

Interaction-free ghost-imaging of structured objects (Conference Presentation)

Yingwen Zhang, Alicia Sit, Frédéric Bouchard +6 more

Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.

•Mar 5, 2019•0 citations
Abstract A modification of the classical scheme of the quantum ghost image formation is considered, in which an image of the object under study is formed and recorded in the object channel. This image is used together with the ghost image to construct an estimate of the transparency distribution of the object. It is shown that this technique reduces the image quality worsening associated with the non-unit quantum efficiency of the sensors, even when the quantum image obtained in the object channel is additionally distorted by noise due to photons that did not interact with the object.
Abstract We investigate the possibilities of increasing the measurement accuracy and creating the least-damaging regime of object illumination by mathematical simulation of the process of generating paired images, that is, a ghost image and a regular image, using a new scheme with quantum biphoton generation. It is shown that diffraction and non-unit quantum efficiency of the sensors in traditional ghost imaging cause missing some information carried by the object arm photons. Forming an image of the studied object in the object arm and registering it makes it possible to weaken the influence of these factors on the measurement result when using the developed version of the method of measurement reduction to the form that is typical for measuring the transparency distribution of the object for processing a pair of obtained images.
Ghost imaging allows extracting information about an object from the spatial correlation function between the photons that interacted with an object and the photons in the reference arm(s). The reference beam does not interact with the object; however, it is measured by a CCD matrix. The mathematical method of measurement reduction allows using both the mutual correlations of multiplexed ghost images and prior information about how the image of the research object can look in order to improve the quality of the reconstructed image. The information about the object is the sparsity of its transparency distribution under a given transform. Computer modelling of image reconstruction using multiplexed ghost images formed by four-mode entangled quantum light states confirms the efficiency of the proposed algorithm even with a small number of photons that illuminate the research object.
Nonlocal point-to-point correlations between two photons have been used to produce ``ghost'' images without placing the camera towards the object. Here we theoretically demonstrate and analyze the advantage of non-Gaussian quantum light in improving the image quality of a ghost imaging system over a traditional Gaussian light source. For any squeezing degree, the signal-to-noise ratio (SNR) of the ghost image can be enhanced by the non-Gaussian operations of photon addition and subtraction on a two-mode squeezed light source. We find striking evidence that using non-Gaussian coherent operations, the SNR can be promoted to a high level even within the extremely weak squeezing regime. The resulting insight provides experimental recipes of quantum imaging using non-Gaussian light for illumination.
When observing a ghost image, information on an object is obtained by measuring the spatial correlation between photons propagating in the object and reconstruction channels. In the traditional schemes involving two-mode entangled quantum states or quasithermal light sources, the correlation function of photons has a background associated with the average number of photons in the channels. It has been shown in this work that the use of polarization-entangled states, e.g., Bell states, allows removing this background and, thereby, obtaining a higher quality reconstructed image.
The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.
Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.