The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.
The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.
Imaging systems play a crucial role in shaping understanding of our surroundings. Modern imaging systems enable the acquisition of images of objects at length-scales and resolutions previously deemed impossible. However, as the drive for better images and novel applications increases, several questions fundamental to our understanding of imaging are being raised. We are familiar with images containing many millions of photons, but how many photons does it take to form an image? In scenarios requiring covert imaging, or where high-light levels damage the sample being imaged, is it possible to image a sample with a very small number of very low-energy photons? This thesis will focus on answering these two questions. In order to answer these questions I developed a heralded quantum imaging system. The strong spatial correlations inherent between down-converted twin photons have been utilised in many quantum imaging techniques for the past 25 years. Thus far, standard quantum imaging techniques have relied on scanning a fibre detector across the field of view in order to measure the spatial information in the image. However, the scanning mechanism fundamentally limits the detection efficiency of the imaging system. Recent years have seen an increased interest in using the latest camera technology within quantum imaging systems. The advent of single-photon-sensitive cameras has opened up new possibilities within the quantum imaging field. It is now possible to obtain images of objects by detecting very low-light illumination across the full scene simultaneously. In the heralded quantum imaging system presented in this thesis, a combination of quantum mechanics and a high-sensitivity camera was employed to obtain high contrast images containing very few photons. This was the first such system built. Using the correlations between the twin photons generated by our down-conversion source, and our development of compressive sampling techniques to post-process the acquired data enabled the acquisition of an image containing an average of only 0.5 photons per pixel. This represents a significant reduction when compared with a conventional image that contains of order 105 photons per pixel. I also developed this imaging system to use twin photons at vastly different wave- lengths. The object was probed with low-energy infrared photons whilst the image was developed on a camera using the correlated visible photon. This disparity in energy between the two photons enabled the acquisition of images using only several thousand photons, corresponding to an energy deposition on the sample of only a few pJ.
Quantum ghost imaging harnesses entangled photon pairs to form images using light that never directly interacts with the object. Conventional approaches rely on pixelated detectors or spatial masks, where the resolution is fundamentally limited by the pixel size and thus bounded by the Rayleigh criterion. In this work, we present a modal approach that replaces pixel-based detection with measurements in a basis of structured modes. By reconstructing images through tailored spatial modes, we decouple resolution from the physical limitations of detectors and instead tie it to the system’s optical precision and computational control. We demonstrate that even non-orthogonal modal sets can achieve high fidelity image reconstruction by exploiting modal sparsity, significantly reducing the number of required measurements. Using phase-only approximations of Hermite-Gaussian modes, we avoid the loss associated with complex amplitude modulation while retaining high reconstruction fidelity. The result is a high-resolution, high-efficiency quantum ghost imaging technique powered by structured light, opening new possibilities for photon-efficient imaging in low-light and quantum-limited regimes, such as biological microscopy and remote sensing.
Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.
“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.
Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.
The UK is continuing its drive to commercialise Quantum Technology in Imaging, Sensing, Communications and Computing. In the first part of my talk I will give an overview of the work of QuantIC, the UK hub tasked with bringing quantum technology to bear on real world imaging challenges, across the industrial, scientific, security and consumer markets.
In the second part of my talk I will feature some of my own group’s work on using quantum illumination to both increase image resolution and suppress background and detector noise. Pairs of photons that are quantum entangled with each other are correlated in many degrees of freedom, creation-time, energy, lateral position etc. Fundamentally this means that measuring one of the photons gives near-perfect prediction of the corresponding property of the other photon. In an imaging context, this second photon with known properties can then be used to probe an object. Using the correlations inherent in this entanglement we are able to increase the resolution of an imaging system and suppress both sensor noise and background light. Our immediate goal is to recover an image of the object without interference from any thermal background or other light sources that might otherwise obscure or confuse what we are seeing. This work in the optical regime has strong parallels with proposals around quantum radar and it is an interesting exercise to consider what one might inform with respect to the other.