Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.
Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.
Quantum - or classically correlated - light can be employed in various ways to improve resolution and measurement sensitivity. In an "interaction-free" measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. With a technique known as "ghost-imaging", entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term "interaction-free ghost-imaging" (IFGI). With this new technique, we reduce photon illumination on the object by up to 26.5% while still maintaining at least the same image quality of conventional ghost-imaging. Alternatively, IFGI can improve image signal-to-noise ratio by 18% when given the same number of interacting photons as in standard ghost-imaging. IFGI is also sensitive to phase and polarisation changes of the photons introduced by a structured object. These advantages make IFGI superior for probing light-sensitive materials and biological tissues.
Quantum imaging techniques offer enhanced resolution, contrast, and precision at ultralow illumination levels compared to traditional imaging approaches. Relying on the unique properties of entangled photon pairs, two of these techniques stand out: the correlation-based quantum imaging technique provides visibility enhancement in imaging of a low-reflectivity object which is subject to excessive noise and losses, while the interaction-free ghost imaging allows for probing the presence of an object with an ultimately low number of photons. Here we propose a quantum imaging scheme that combines the unique advantages of these two approaches. We show that this scheme offers high-contrast imaging of objects with a minimal number of photons that can minimize thermal noise efficiently and create background-free images. We anticipate that this approach can find application in the imaging of photosensitive biological tissues in a noninvasive and harm-free fashion.
The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.
Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.
Quantum ghost imaging harnesses entangled photon pairs to form images using light that never directly interacts with the object. Conventional approaches rely on pixelated detectors or spatial masks, where the resolution is fundamentally limited by the pixel size and thus bounded by the Rayleigh criterion. In this work, we present a modal approach that replaces pixel-based detection with measurements in a basis of structured modes. By reconstructing images through tailored spatial modes, we decouple resolution from the physical limitations of detectors and instead tie it to the system’s optical precision and computational control. We demonstrate that even non-orthogonal modal sets can achieve high fidelity image reconstruction by exploiting modal sparsity, significantly reducing the number of required measurements. Using phase-only approximations of Hermite-Gaussian modes, we avoid the loss associated with complex amplitude modulation while retaining high reconstruction fidelity. The result is a high-resolution, high-efficiency quantum ghost imaging technique powered by structured light, opening new possibilities for photon-efficient imaging in low-light and quantum-limited regimes, such as biological microscopy and remote sensing.
We propose an interaction-free ghost imaging scheme based on a thermal light source. By utilizing the quantum Zeno-like effect, our approach significantly reduces the light dose absorbed by the sample, thereby effectively preventing sample damage induced by light-matter interactions. Combined with the elimination of entangled photon sources and single-photon detectors, our approach enables significantly more photons to be utilized for image reconstruction, thereby markedly enhancing image quality compared to conventional ghost imaging. We further demonstrate active suppression of background noise via controllable photon loss. Our work offers a practical and cost-effective route to non-destructive, high-quality imaging for light-sensitive samples in fields such as life sciences.