IEEE Magnetics Letters

Zero Magnetic Field Calibration for Single-Beam Atomic Magnetometers Using Second Harmonics

Khanuengchat Saenyot, Yuya Shoji, Shunya Takahashi, M. Daibo

Published Jan 1, 2019• 6 citations
Publisher

Abstract

In this letter, we propose a simple and rapid method for zero field calibration of single elliptically polarized beam atomic magnetometers. This method uses a wobble adjustment that applies a small amplitude and low-frequency (70 Hz) ac magnetic field and sweeps the dc magnetic field. The second harmonic signal reaches its maximum when the dc magnetic field noise is zero. Our single-beam atomic magnetometer operates with elliptically polarized light, which has both circularly and linearly polarized light components. The wavelength of a single beam for a rubidium atom was determined to be 780.206 nm with a power of 2.72 mW.

DOI
10.1109/lmag.2019.2944804

Related papers

DC-Bias-Magnetic-Field Dependence of Step Response in an Elliptically Polarized Single-Beam Atomic Magnetometer

Yuya Shoji, Khanuengchat Saenyot, Shunya Takahashi +1 more

A single-beam atomic magnetometer with elliptical polarization is simple in construction because it requires only one laser for both pumping and probing. When a small-signal magnetic field is input into the magnetometer after the DC magnetic field is set to zero, a full-wave cleared waveform is output. This characteristic is appropriate for calibration and measurement of DC magnetic fields, because the bias of such fields affects their sensitivity. In this paper, we examined the step-response waveform when a pulsed magnetic field with various DC magnetic-field biases was applied. The response waveform was measured in the time domain with an oscilloscope. The oscillation frequency did not depend on the step-magnetic-field difference but on the amplitude when changing from an absolute-zero magnetic field to a finite magnetic field. Because the DC magnetic field can be determined by measuring the frequency, the bias magnetic field of the atomic magnetometer can be adjusted to maintain the optimal point of operation.

International Electrical Engineering Congress (iEECON)•Mar 1, 2020•1 citation

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•123 citations

Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.

arXiv:2410.15663•Applied Physics Letters•Jan 27, 2025•8 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•11 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations

Reflected Atomic Magnetometer With Single Beam

Xuejing Liu, Yang Li, Xudong Wu +3 more

A reflected atomic magnetometer with single beam is described in this study. A single beam propagates forward for polarizing the atoms and backward for detecting Larmor precession after reflection. The feasibility of the system was studied theoretically and experimentally and compared with the single beam with ellipticity. In reflected scheme, high pump efficiency ensures a reduced power and more flexible operating wavelength considering the AC Stark shift, pump efficiency, and probe signal. The nonuniform optical rotation distribution along the cell was also analyzed. The wavelength of the system was optimized to 795.3 nm. The magnetic field sensitivity of the system is achieved to be 600 fT/Hz1/2and the experimental bandwidth was 17 Hz. The compact design enables new possibility of the atomic magnetometer for magnetoencephalography systems.

IEEE Sensors Journal•Jan 15, 2022•9 citations
In this letter, we propose a simple and rapid method for zero field calibration of single elliptically polarized beam atomic magnetometers. This method uses a wobble adjustment that applies a small amplitude and low-frequency (70 Hz) ac magnetic field and sweeps the dc magnetic field. The second harmonic signal reaches its maximum when the dc magnetic field noise is zero. Our single-beam atomic magnetometer operates with elliptically polarized light, which has both circularly and linearly polarized light components. The wavelength of a single beam for a rubidium atom was determined to be 780.206 nm with a power of 2.72 mW.
A single-beam atomic magnetometer with elliptical polarization is simple in construction because it requires only one laser for both pumping and probing. When a small-signal magnetic field is input into the magnetometer after the DC magnetic field is set to zero, a full-wave cleared waveform is output. This characteristic is appropriate for calibration and measurement of DC magnetic fields, because the bias of such fields affects their sensitivity. In this paper, we examined the step-response waveform when a pulsed magnetic field with various DC magnetic-field biases was applied. The response waveform was measured in the time domain with an oscilloscope. The oscillation frequency did not depend on the step-magnetic-field difference but on the amplitude when changing from an absolute-zero magnetic field to a finite magnetic field. Because the DC magnetic field can be determined by measuring the frequency, the bias magnetic field of the atomic magnetometer can be adjusted to maintain the optimal point of operation.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
A reflected atomic magnetometer with single beam is described in this study. A single beam propagates forward for polarizing the atoms and backward for detecting Larmor precession after reflection. The feasibility of the system was studied theoretically and experimentally and compared with the single beam with ellipticity. In reflected scheme, high pump efficiency ensures a reduced power and more flexible operating wavelength considering the AC Stark shift, pump efficiency, and probe signal. The nonuniform optical rotation distribution along the cell was also analyzed. The wavelength of the system was optimized to 795.3 nm. The magnetic field sensitivity of the system is achieved to be 600 fT/Hz1/2and the experimental bandwidth was 17 Hz. The compact design enables new possibility of the atomic magnetometer for magnetoencephalography systems.