A reflected atomic magnetometer with single beam is described in this study. A single beam propagates forward for polarizing the atoms and backward for detecting Larmor precession after reflection. The feasibility of the system was studied theoretically and experimentally and compared with the single beam with ellipticity. In reflected scheme, high pump efficiency ensures a reduced power and more flexible operating wavelength considering the AC Stark shift, pump efficiency, and probe signal. The nonuniform optical rotation distribution along the cell was also analyzed. The wavelength of the system was optimized to 795.3 nm. The magnetic field sensitivity of the system is achieved to be 600 fT/Hz1/2and the experimental bandwidth was 17 Hz. The compact design enables new possibility of the atomic magnetometer for magnetoencephalography systems.
A reflected atomic magnetometer with single beam is described in this study. A single beam propagates forward for polarizing the atoms and backward for detecting Larmor precession after reflection. The feasibility of the system was studied theoretically and experimentally and compared with the single beam with ellipticity. In reflected scheme, high pump efficiency ensures a reduced power and more flexible operating wavelength considering the AC Stark shift, pump efficiency, and probe signal. The nonuniform optical rotation distribution along the cell was also analyzed. The wavelength of the system was optimized to 795.3 nm. The magnetic field sensitivity of the system is achieved to be 600 fT/Hz1/2and the experimental bandwidth was 17 Hz. The compact design enables new possibility of the atomic magnetometer for magnetoencephalography systems.
The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
In recent years, atomic magnetometers (AMs) have demonstrated sub-femtotesla sensitivities and have emerged as potential replacements for superconducting quantum interference devices (SQUIDs). In an AM, a circularly polarized pump laser aligns the electron spins in a cloud of alkali metal vapor. Changes occur in the optical properties of the vapor when its collective moment interacts with an external magnetic field, resulting in a measurable polarization rotation of a linearly polarized probe beam. We present a unique pump/probe scheme in which a pump beam tuned to the87Rb D1 line (795 nm) and a probe beam tuned to the D2 line (780 nm) share a single optical axis. A dichroic waveplate is used to circularly polarize the pump beam while leaving the probe beam linearly polarized. Based upon this scheme, we have developed a small profile, fiber-coupled AM. By independently optimizing pump/probe power and detuning, we are able to achieve intrinsic single-channel sensitivity of <; 5 fT/√Hz, which is suitable for demanding applications such as magnetoencephalography (MEG). Furthermore, through straightforward adaptations of the current design, it should be possible to create dense, reconfigurable arrays of AMs for whole-head MEG.