Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Journal of Lasers

Design of Microwave Cavity for in Situ Atom Detection Used in Space Cold Atom Clock

王新文 Xinwen Wang, Yuanci Gao, 赵剑波 Jianbo Zhao, 彭向凯 Xiangkai Peng, 任伟 Wei Ren, Jingfeng Xiang, 张镇 Zhen Zhang, Gongxun Dong, 刘亢亢 Kangkang Liu, Qiuzhi Qu, 刘亮 Liang Liu, 吕德胜 Lü Desheng

Published Jan 1, 2019• 0 citations
Publisher
DOI
10.3788/cjl201946.0901006

Related papers

Performance Analysis of Space Cold Atomic Clock Based on In-Situ Atomic Detection

彭向凯 Peng Xiangkai, 任伟 Ren Wei, 项静峰 Xiang Jingfeng +3 more

Acta Optica Sinica•Jan 1, 2019•1 citation

Design of the cold atom PHARAO space clock and initial test results

Philippe Laurent, Michel Abgrall, Ch. Jentsch +17 more

Applied Physics B•Aug 31, 2006•118 citations

New design of the compact cold atoms clock HORACE

François-Xavier Esnault, Sean Perrin, S. Trémine +5 more

In the compact cold atoms clock HORACE caesium atoms are successively laser cooled, submitted to a Ramsey microwave interrogation scheme and then detected by linear absorption directly inside the microwave cavity. The whole physics package and optical bench have been entirely redesigned to optimize such an in-situ detection and to perform a normalization scheme. Main efforts have been concentrated on technical issues such as magnetic shielding, microwave cavity polishing and tuning, use of fast mechanical switches to realize the optical sequence.

•Jan 1, 2006•6 citations

Cold atom microwave clock based on intracavity cooling in China space station

Siminda Deng, Wei Ren, Jingfeng Xiang +9 more

Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.

npj Microgravity•Jun 6, 2024•15 citations

Development of an ultra-high vacuum system for space cold atom clock

Wei Ren, Jingfeng Xiang, Yuantao Zhang +6 more

Vacuum•Mar 11, 2015•13 citations

Towards a monolithic optical cavity for atom detection and manipulation

S. Gleyzes, Abdelkrim El Amili, R. A. Cornelussen +11 more

arXiv:0901.0513•The European Physical Journal D•Mar 19, 2009•8 citations
In the compact cold atoms clock HORACE caesium atoms are successively laser cooled, submitted to a Ramsey microwave interrogation scheme and then detected by linear absorption directly inside the microwave cavity. The whole physics package and optical bench have been entirely redesigned to optimize such an in-situ detection and to perform a normalization scheme. Main efforts have been concentrated on technical issues such as magnetic shielding, microwave cavity polishing and tuning, use of fast mechanical switches to realize the optical sequence.
Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.