Vacuum

Development of an ultra-high vacuum system for space cold atom clock

Wei Ren, Jingfeng Xiang, Yuantao Zhang, Bin Wang, Qiuzhi Qu, Jian-Bo Zhao, Meifeng Ye, Desheng Lü, Liang Liu

Published Mar 11, 2015• 13 citations
Publisher
DOI
10.1016/j.vacuum.2015.03.001

Related papers

Development of an ultra-high vacuum system for a cold atom physics rack in space

Qian Liu, Y. Xie, Lin Li +7 more

Vacuum•Mar 13, 2021•12 citations

Cold atom technology applied to ultra-high vacuum (UHV) measurements

Wenjun Sun, Xiangmin Wu, Yongjun Cheng +8 more

Vacuum•Feb 23, 2024•6 citations

Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories

Ben Stray, O. Ennis, Hedges, S. +69 more

This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.

arXiv:2305.20060•May 31, 2023•1 citation

Centralized design and production of the ultra-high vacuum and laser-stabilization systems for the AION ultra-cold strontium laboratories

Ben Stray, O. Ennis, Sam Hedges +69 more

This paper outlines the centralized design and production of the ultra-high-vacuum sidearm and laser-stabilization systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilization, and on the loading rate for the 3D magneto-optical trap are presented. Streamlining the design and production of the sidearm and laser stabilization systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.

AVS Quantum Science•Mar 1, 2024•6 citations

Development of a compact cold atom clock with a cylindrical cavity

Liang Liu, Hua-Dong Cheng, Peng Liu +5 more

Bulletin of the American Physical Society•Jun 9, 2015•0 citations

Principle and Progress of Cold Atom Clock in Space

屈求智 Qu Qiuzhi, 汪斌 Wang Bin, 吕德胜 Lü Desheng +4 more

Chinese Journal of Lasers•Jan 1, 2015•3 citations
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.
This paper outlines the centralized design and production of the ultra-high-vacuum sidearm and laser-stabilization systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilization, and on the loading rate for the 3D magneto-optical trap are presented. Streamlining the design and production of the sidearm and laser stabilization systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.