Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Optica Sinica

Performance Analysis of Space Cold Atomic Clock Based on In-Situ Atomic Detection

彭向凯 Peng Xiangkai, 任伟 Ren Wei, 项静峰 Xiang Jingfeng, 王新文 Wang Xinwen, 刘亮 Liu Liang, 吕德胜 Lü Desheng

Published Jan 1, 2019• 1 citation
Publisher
DOI
10.3788/aos201939.0802001

Related papers

Design of Microwave Cavity for in Situ Atom Detection Used in Space Cold Atom Clock

王新文 Xinwen Wang, Yuanci Gao, 赵剑波 Jianbo Zhao +9 more

Chinese Journal of Lasers•Jan 1, 2019•0 citations

Cold atoms in space and atomic clocks: ACES

Ch Salomon, N. Dimarcq, Michel Abgrall +17 more

Comptes Rendus de l Académie des Sciences - Series IV - Physics-Astrophysics•Nov 1, 2001•91 citations

Cold atom microwave clock based on intracavity cooling in China space station

Siminda Deng, Wei Ren, Jingfeng Xiang +9 more

Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.

npj Microgravity•Jun 6, 2024•15 citations

Principle and Progress of Cold Atom Clock in Space

屈求智 Qu Qiuzhi, 汪斌 Wang Bin, 吕德胜 Lü Desheng +4 more

Chinese Journal of Lasers•Jan 1, 2015•3 citations

Atomic clock based on a free expanding cloud of cold atoms: comparison with a beam clock

Stella Müller, Aida Bebeachibuli, Renato Ferracini Alves +3 more

Book of Abstracts Student Research•Jan 1, 2006•0 citations

Physics package based on intracavity laser cooling 87Rb atoms for space cold atom microwave clock

Siminda 思敏达 Deng 邓, Wei 伟 Ren 任, Jingfeng Xiang +9 more

This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation, microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2 × 10−12 τ −1/2 with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future.

Chinese Physics B•May 15, 2024•5 citations
Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation, microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2 × 10−12 τ −1/2 with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future.