Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Information and Measurement (QIM)

Quantum Measurement and Control of a Mechanical Resonator

Massimiliano Rossi, David Mason, Junxin Chen, Yeghishe Tsaturyan, Albert Schließer

Published Jan 1, 2019• 2 citations
Publisher

Abstract

We measure mechanical displacements within 35% of the Heisenberg limit, allowing to both track the quantum trajectory of the highly pure (purity 80%) mechanical state conditioned on this measurement, and ground-state cool via quantum feedback.
DOI
10.1364/qim.2019.s1c.4

Related papers

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David L. Mason, Junxin Chen +2 more

We measure mechanical displacements within 35% of the Heisenberg limit. By exploiting quantum correlations in an optomechanical system, we achieve for the first time a total sensitivity below the standard quantum limit by 1.5 dB. © 2019 The Author(s)

Conference on Lasers and Electro-Optics•May 1, 2019•0 citations

Cooling a micromechanical resonator to its ground state by measurement and feedback

Christian Bergenfeldt, Klaus Mølmer

We present an analysis of the cooling of a micromechanical resonator by means of measurement and feedback. The measurements are performed via the coupling to a Cooper-pair box, and although the coupling does not lead to net cooling, the extraction of information and hence entropy from the system leads to a pure quantum state. Under suitable circumstances, the states become very close to coherent states, conditioned on the measurement record, and can hence be displaced to the oscillator ground state.

arXiv:0906.1909•Physical Review A•Oct 27, 2009•8 citations

Quantum Measurement of a Mechanical Resonator At and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen +2 more

Conference on Lasers and Electro-Optics•Jan 1, 2019•0 citations

Observing and Verifying the Quantum Trajectory of a Mechanical Resonator

Massimiliano Rossi, David Mason, Junxin Chen +1 more

Continuous weak measurement allows localizing open quantum systems in state space and tracing out their quantum trajectory as they evolve in time. Efficient quantum measurement schemes have previously enabled recording quantum trajectories of microwave photon and qubit states. We apply these concepts to a macroscopic mechanical resonator, and we follow the quantum trajectory of its motional state conditioned on a continuous optical measurement record. Starting with a thermal mixture, we eventually obtain coherent states of 78% purity-comparable to a displaced thermal state of occupation 0.14. We introduce a retrodictive measurement protocol to directly verify state purity along the trajectory, and we furthermore observe state collapse and decoherence. This opens the door to measurement-based creation of advanced quantum states, as well as potential tests of gravitational decoherence models.

arXiv:1812.00928•Physical Review Letters•Oct 14, 2019•99 citations

Measurement and control of a mechanical oscillator at its thermal decoherence rate 1 DALZIEL WILSON, VIVISHEK SUDHIR, NICOLAS PIRO,

Ryan Schilling, Amir Hossein Ghadimi, Tobias Jan Kippenberg +1 more

cavityoptomechanical coupling, and realizes a measurement of the oscillator’s displacement with an imprecision 40 dB below that at the standard quantum limit, while maintaining an imprecision-backaction product within a factor of 5 of the Heisenberg uncertainty limit. As a demonstration of its utility, we use the measurement to feedback cool the oscillator to an phonon occupation of 5.4 0.7 (i.e, a ground state probablity of 16%). Our results establish a new benchmark for the performance of a linear position sensor, and signal the emergence of engineered mechanical oscillators as practical subjects for measurement-based quantum control.

•Jan 1, 2014•16 citations

Picometer control of a levitating milligram gravity sensor

Dennis G. Uitenbroek, Jurriaan Langendorff, Tjerk H. Oosterkamp

Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of $3.8 \cdot 10^6$ and $5.5 \cdot 10^6$ respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.

quant-pharXiv:2605.28479•May 28, 2026
We present an analysis of the cooling of a micromechanical resonator by means of measurement and feedback. The measurements are performed via the coupling to a Cooper-pair box, and although the coupling does not lead to net cooling, the extraction of information and hence entropy from the system leads to a pure quantum state. Under suitable circumstances, the states become very close to coherent states, conditioned on the measurement record, and can hence be displaced to the oscillator ground state.
Continuous weak measurement allows localizing open quantum systems in state space and tracing out their quantum trajectory as they evolve in time. Efficient quantum measurement schemes have previously enabled recording quantum trajectories of microwave photon and qubit states. We apply these concepts to a macroscopic mechanical resonator, and we follow the quantum trajectory of its motional state conditioned on a continuous optical measurement record. Starting with a thermal mixture, we eventually obtain coherent states of 78% purity-comparable to a displaced thermal state of occupation 0.14. We introduce a retrodictive measurement protocol to directly verify state purity along the trajectory, and we furthermore observe state collapse and decoherence. This opens the door to measurement-based creation of advanced quantum states, as well as potential tests of gravitational decoherence models.
cavityoptomechanical coupling, and realizes a measurement of the oscillator’s displacement with an imprecision 40 dB below that at the standard quantum limit, while maintaining an imprecision-backaction product within a factor of 5 of the Heisenberg uncertainty limit. As a demonstration of its utility, we use the measurement to feedback cool the oscillator to an phonon occupation of 5.4 0.7 (i.e, a ground state probablity of 16%). Our results establish a new benchmark for the performance of a linear position sensor, and signal the emergence of engineered mechanical oscillators as practical subjects for measurement-based quantum control.
Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of 3.8⋅1063.8 \cdot 10^63.8⋅106 and 5.5⋅1065.5 \cdot 10^65.5⋅106 respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.