Conference on Lasers and Electro-Optics

Quantum Measurement of a Mechanical Resonator At and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen, Yeghishe Tsaturyan, Albert Schließer

Published Jan 1, 2019• 0 citations
Publisher
DOI
10.1364/cleo_qels.2019.fm1a.3

Related papers

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen +2 more

Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•1 citation

Mechanical resonators and quantum measurements

Hiroshi Yamaguchi

The Japan Society of Applied Physics•Jul 8, 2014•0 citations

Harnessing quantum correlations for physics beyond the standard quantum limit in broadband displacement detection

N. S. Kampel, Robert W. Peterson, Ran Fischer +5 more

When one seeks knowledge of the full dynamics of the displacement of a harmonic oscillator, non-commutation of the two mechanical quadratures requires a minimum added noise equal to the mechanical resonator's zero point motion. This fundamental quantum limit (QL) is a distinct bound from the standard quantum limit (SQL) that is often considered in interferometric displacement measurement. The SQL is a consequence of the non-commutation of the probe's quadratures in a specific measurement configuration and is characterized by a tradeoff between shot noise (SN) imprecision and quantum backaction that are uncorrelated. The QL and SQL reach the same limit when probing at the peak mechanical response, but the QL can be a significantly lower bound off resonance. In studies of micro-mechanical motion, there has been great interest in observing quantum backaction and approaching the SQL on mechanical resonance. However, much of what historically motivates SQL research is displacement monitoring over a wide frequency band, such as gravitational wave searches. One long-standing concept for surpassing the SQL is to introduce correlations by changing the readout quadrature as a function of frequency in a technique known as variational readout. Here we harness quantum correlations in the measurement of a macroscopic resonator by modifying the readout quadrature of an optical interferometer. By using an optomechanical device thermalized to a dilution refrigerator, we measure quantum noise far off resonance where we improve upon the off-resonance SQL for our quantum efficiency.

•Jul 22, 2016•2 citations

Quantum Limits on Measurement and Control of a Mechanical Oscillator

Vivishek Sudhir

Springer theses•Nov 22, 2017•2 citations

Testing Quantum Mechanics in a Mechanical System: Characterizing Mechanical Resonators

Santa Bárbara

•Jan 1, 2009•0 citations

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David L. Mason, Junxin Chen +2 more

We measure mechanical displacements within 35% of the Heisenberg limit. By exploiting quantum correlations in an optomechanical system, we achieve for the first time a total sensitivity below the standard quantum limit by 1.5 dB. © 2019 The Author(s)

Conference on Lasers and Electro-Optics•May 1, 2019•0 citations
Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.
When one seeks knowledge of the full dynamics of the displacement of a harmonic oscillator, non-commutation of the two mechanical quadratures requires a minimum added noise equal to the mechanical resonator's zero point motion. This fundamental quantum limit (QL) is a distinct bound from the standard quantum limit (SQL) that is often considered in interferometric displacement measurement. The SQL is a consequence of the non-commutation of the probe's quadratures in a specific measurement configuration and is characterized by a tradeoff between shot noise (SN) imprecision and quantum backaction that are uncorrelated. The QL and SQL reach the same limit when probing at the peak mechanical response, but the QL can be a significantly lower bound off resonance. In studies of micro-mechanical motion, there has been great interest in observing quantum backaction and approaching the SQL on mechanical resonance. However, much of what historically motivates SQL research is displacement monitoring over a wide frequency band, such as gravitational wave searches. One long-standing concept for surpassing the SQL is to introduce correlations by changing the readout quadrature as a function of frequency in a technique known as variational readout. Here we harness quantum correlations in the measurement of a macroscopic resonator by modifying the readout quadrature of an optical interferometer. By using an optomechanical device thermalized to a dilution refrigerator, we measure quantum noise far off resonance where we improve upon the off-resonance SQL for our quantum efficiency.