Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Electronics and Laser Science Conference

Quantum measurement of force with an error less than the standard quantum limit

S. P. Vyatchanin, Е. А. Зубова

Published May 22, 1995• 0 citations
OpenAlex

Related papers

Continuous force and displacement measurement below the standard quantum limit

David Mason, Junxin Chen, Massimiliano Rossi +2 more

arXiv:1809.10629•Nature Physics•May 27, 2019•236 citations

Complex squeezing for force measurement beyond the standard quantum limit

Sydney Schreppler, Lukas F. Buchmann, Jonathan Kohler +2 more

Bulletin of the American Physical Society•Mar 15, 2016•0 citations

The standard quantum limit for the measurement of weak forces using a tunnel transducer

V. P. Mitrofanov, V. N. Iakimov

Moscow University Physics Bulletin•Aug 1, 1989•0 citations

Quantum limit on force measurements

Sergey P. Vyatchanin, Andrey B. Matsko

Journal of Experimental and Theoretical Physics•Aug 1, 1993•18 citations

The Estimation of Signal Force Parameters in Quantum Variation Measurement

Sergey P. Vyatchanin

Abstract It is shown by examples that the procedure of a quantum variation measurement allows one to estimate simultaneously several parameters of the signal force (amplitude, arrival time, frequency) with errors much less than the standard quantum limit.

European Quantum Electronics Conference (EQEC)•Aug 24, 2005•1 citation

Quantum limit of the resolution in force measurement in an active interferometric optical displacement transducer

Andrey B. Matsko

The quantum limit for resolution in force measurement using active interferometric optical transducer of displacement is proved to be less than the standard quantum limit (SQL) if one measures not the phase but a specially chosen quadrature amplitude in the output wave, squeezed by a mechanism of ponderomotive nonlinearity. Consideration of two types of active transducer having three-level atoms gain and parametric gain is given. Noises of spontaneous emission, fluctuations due to losses in mirrors and effect of radiative friction are taken into account.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 6, 1996•0 citations
The quantum limit for resolution in force measurement using active interferometric optical transducer of displacement is proved to be less than the standard quantum limit (SQL) if one measures not the phase but a specially chosen quadrature amplitude in the output wave, squeezed by a mechanism of ponderomotive nonlinearity. Consideration of two types of active transducer having three-level atoms gain and parametric gain is given. Noises of spontaneous emission, fluctuations due to losses in mirrors and effect of radiative friction are taken into account.