arXiv:2605.28479

Picometer control of a levitating milligram gravity sensor

Dennis G. Uitenbroek, Jurriaan Langendorff, Tjerk H. Oosterkamp

quant-phSubmitted May 27, 2026• Announced May 28, 2026• Revised Jul 1, 2026 (v2)
v1 · May 27, 2026v2 · Jul 1, 2026
arXivHTMLPDF

Abstract

Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of $3.8 \cdot 10^6$ and $5.5 \cdot 10^6$ respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.

Comments
Main: 6 pages including 4 figures. Supplementary Material: 4 pages including 4 figures

Related papers

High- Q Magnetic Levitation and Control of Superconducting Microspheres at Millikelvin Temperatures

Joachim Hofer, R. Gross, Gerard T. Higgins +11 more

We report the levitation of a superconducting lead-tin sphere with 100 μm diameter (corresponding to a mass of 5.6 μg) in a static magnetic trap formed by two coils in an anti-Helmholtz configuration, with adjustable resonance frequencies up to 240 Hz. The center-of-mass motion of the sphere is monitored magnetically using a dc superconducting quantum interference device as well as optically and exhibits quality factors of up to 2.6×10^{7}. We also demonstrate 3D magnetic feedback control of the motion of the sphere. The setup is housed in a dilution refrigerator operating at 15 mK. By implementing a cryogenic vibration isolation system, we can attenuate environmental vibrations at 200 Hz by approximately 7 orders of magnitude. The combination of low temperature, large mass, and high quality factor provides a promising platform for testing quantum physics in previously unexplored regimes with high mass and long coherence times.

arXiv:2211.06289•Physical Review Letters•Jul 25, 2023•57 citations

Measurement and feedback for cooling heavy levitated particles in low-frequency traps

L. S. Walker, Gordon R. M. Robb, Andrew J. Daley

We consider a possible route to ground-state cooling of a levitated nanoparticle, magnetically trapped by a strong permanent magnet, using a combination of measurement and feedback. The trap frequency of this system is much lower than those involving trapped ions or nanomechanical resonators. Minimization of environmental heating is therefore challenging as it requires control of the system on a timescale comparable to the inverse of the trap frequency. We show that these traps are an excellent platform for performing optimal feedback control via real-time state estimation, for the preparation of motional states with measurable quantum properties.

arXiv:1903.10470•Physical Review A•Dec 12, 2019•10 citations

Levitated Milligram-scale Ferromagnetic Magnetometer at Room Temperature

Yuanji Sheng, Kenan Tian, Rui Li +4 more

Levitated mechanical oscillators are emerging ultrasensitive sensors with tremendous potential in both applied and fundamental physics. Levitated ferromagnets, with internal spin noises rapidly averaged, promise ultrahigh magnetic sensitivity. Here, we demonstrate a milligram-scale diamagnetically levitated ferromagnet system operating at room temperature. Through optimized geometry and multi-channel dissipation control, we achieve a magnetic sensitivity of 23~fT$/\sqrt{\text{Hz}}$ at frequency of 100-Hz level. We anticipate that a ferromagnetic magnetometer with subfemtotesla sensitivity is within reach, after modest technical improvements. This platform establishes a high-performance magnetometer for biomagnetic field detection and beyond-standard-model force searches.

quant-pharXiv:2608.08544•Aug 11, 2026

Magnetic Cooling and Vibration Isolation of a Sub-kHz Mechanical Resonator

Bernard van Heck, Tim M. Fuchs, Jaimy Plugge +2 more

Abstract We report recent progress toward the realization of a sub-mK, low-vibration environment at the bottom stage of a dry dilution refrigerator for use in mechanical tests of quantum mechanics. Using adiabatic nuclear demagnetization, we have cooled a silicon cantilever force sensor to $$T\approx 1$$ T ≈ 1 mK. The temperature of the tip holder of the cantilever chip was determined via a primary magnetic flux noise thermometer. The quality factor of the cantilever continues to increase with decreasing temperature, reaching $$Q\approx 4\cdot 10^4$$ Q ≈ 4 · 10 4 at 2 mK. To demonstrate that the vibration isolation is not compromised, we report the detection of the thermal motion of the cantilever down to $$T \approx 20$$ T ≈ 20 mK, only limited by the coupling to the SQUID readout circuit. We discuss feasible improvements that will allow us to probe unexplored regions of the parameter space of continuous spontaneous localization models.

arXiv:2208.11750•Journal of Low Temperature Physics•Feb 4, 2023•7 citations

On-chip levitation of ferromagnetic microparticles

Martijn Janse, M. Luisa Mattana, Julian van Doorn +4 more

Levitation of microscopic objects in vacuum combines exceptional environmental isolation with precise control of their dynamics, pushing the limits of sensing and macroscopic quantum physics. In particular, magnetic levitation allows a large range of particle sizes, while avoiding detrimental effects from high-intensity optical trapping beams and electric field noise. However, existing diamagnetic and Meissner levitation approaches are typically constrained by low mechanical eigenfrequencies, limited integrability with other systems due to bulky coils or magnets, and, for Meissner levitation, the need for cryogenic operation. Here, we demonstrate a room-temperature on-chip magnetic levitation platform capable of stably levitating a nanogram (6.5 micrometer radius) ferromagnetic microsphere. The platform is scalable and tunable, and supports librational modes with eigenfrequencies exceeding 10 kHz. Further miniaturization and coupling to solid-state spin qubits could enable cooling to the quantum ground state. Beyond quantum experiments, this architecture enables integrated precision sensing and studies of isolated ferromagnet thermodynamics.

quant-pharXiv:2605.00090•May 4, 2026

Remote sensing of a levitated superconductor with a flux-tunable microwave cavity

Philip Schmidt, Remi Claessen, Gerard T. Higgins +10 more

We present a cavity-electromechanical system comprising a superconducting quantum interference device which is embedded in a microwave resonator and coupled via a pickup loop to a 6 - μ g magnetically levitated superconducting sphere. The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system. We use microwave spectroscopy to characterize the system, and we demonstrate that the electromechanical interaction is tunable. The measured displacement sensitivity of 10 − 7 m / Hz defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures. Published by the American Physical Society 2024

arXiv:2401.08854•Physical Review Applied•Jul 30, 2024•9 citations
Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of 3.8⋅1063.8 \cdot 10^63.8⋅106 and 5.5⋅1065.5 \cdot 10^65.5⋅106 respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.
We report the levitation of a superconducting lead-tin sphere with 100 μm diameter (corresponding to a mass of 5.6 μg) in a static magnetic trap formed by two coils in an anti-Helmholtz configuration, with adjustable resonance frequencies up to 240 Hz. The center-of-mass motion of the sphere is monitored magnetically using a dc superconducting quantum interference device as well as optically and exhibits quality factors of up to 2.6×10^{7}. We also demonstrate 3D magnetic feedback control of the motion of the sphere. The setup is housed in a dilution refrigerator operating at 15 mK. By implementing a cryogenic vibration isolation system, we can attenuate environmental vibrations at 200 Hz by approximately 7 orders of magnitude. The combination of low temperature, large mass, and high quality factor provides a promising platform for testing quantum physics in previously unexplored regimes with high mass and long coherence times.
We consider a possible route to ground-state cooling of a levitated nanoparticle, magnetically trapped by a strong permanent magnet, using a combination of measurement and feedback. The trap frequency of this system is much lower than those involving trapped ions or nanomechanical resonators. Minimization of environmental heating is therefore challenging as it requires control of the system on a timescale comparable to the inverse of the trap frequency. We show that these traps are an excellent platform for performing optimal feedback control via real-time state estimation, for the preparation of motional states with measurable quantum properties.
Levitated mechanical oscillators are emerging ultrasensitive sensors with tremendous potential in both applied and fundamental physics. Levitated ferromagnets, with internal spin noises rapidly averaged, promise ultrahigh magnetic sensitivity. Here, we demonstrate a milligram-scale diamagnetically levitated ferromagnet system operating at room temperature. Through optimized geometry and multi-channel dissipation control, we achieve a magnetic sensitivity of 23~fT/Hz/\sqrt{\text{Hz}}/Hz​ at frequency of 100-Hz level. We anticipate that a ferromagnetic magnetometer with subfemtotesla sensitivity is within reach, after modest technical improvements. This platform establishes a high-performance magnetometer for biomagnetic field detection and beyond-standard-model force searches.
Abstract We report recent progress toward the realization of a sub-mK, low-vibration environment at the bottom stage of a dry dilution refrigerator for use in mechanical tests of quantum mechanics. Using adiabatic nuclear demagnetization, we have cooled a silicon cantilever force sensor to T≈1T\approx 1T≈1 T ≈ 1 mK. The temperature of the tip holder of the cantilever chip was determined via a primary magnetic flux noise thermometer. The quality factor of the cantilever continues to increase with decreasing temperature, reaching Q≈4⋅104Q\approx 4\cdot 10^4Q≈4⋅104 Q ≈ 4 · 10 4 at 2 mK. To demonstrate that the vibration isolation is not compromised, we report the detection of the thermal motion of the cantilever down to T≈20T \approx 20T≈20 T ≈ 20 mK, only limited by the coupling to the SQUID readout circuit. We discuss feasible improvements that will allow us to probe unexplored regions of the parameter space of continuous spontaneous localization models.
Levitation of microscopic objects in vacuum combines exceptional environmental isolation with precise control of their dynamics, pushing the limits of sensing and macroscopic quantum physics. In particular, magnetic levitation allows a large range of particle sizes, while avoiding detrimental effects from high-intensity optical trapping beams and electric field noise. However, existing diamagnetic and Meissner levitation approaches are typically constrained by low mechanical eigenfrequencies, limited integrability with other systems due to bulky coils or magnets, and, for Meissner levitation, the need for cryogenic operation. Here, we demonstrate a room-temperature on-chip magnetic levitation platform capable of stably levitating a nanogram (6.5 micrometer radius) ferromagnetic microsphere. The platform is scalable and tunable, and supports librational modes with eigenfrequencies exceeding 10 kHz. Further miniaturization and coupling to solid-state spin qubits could enable cooling to the quantum ground state. Beyond quantum experiments, this architecture enables integrated precision sensing and studies of isolated ferromagnet thermodynamics.
We present a cavity-electromechanical system comprising a superconducting quantum interference device which is embedded in a microwave resonator and coupled via a pickup loop to a 6 - μ g magnetically levitated superconducting sphere. The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system. We use microwave spectroscopy to characterize the system, and we demonstrate that the electromechanical interaction is tunable. The measured displacement sensitivity of 10 − 7 m / Hz defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures. Published by the American Physical Society 2024