Optica

Resolution-enhanced quantum imaging by centroid estimation of biphotons

Ermes Toninelli, Paul‐Antoine Moreau, Thomas Gregory, Adam Mihalyi, M. Edgar, Neal Radwell, Miles J. Padgett

Published Mar 8, 2019• 86 citations
Publisher

Abstract

The spatial resolution of an optical system is limited by diffraction. Various schemes have been proposed to achieve resolution enhancement by employing either a scanning source/detector configuration or a two-photon response of the object. Here, we experimentally demonstrate a full-field resolution-enhancing scheme, based on the centroid estimation of spatially quantum-correlated biphotons. Our standard-quantum-limited scheme is able to image a general non-fluorescing object, using low-energy and low-intensity infrared illumination (i.e., with <0.001 photon per pixel per frame at 710 nm), achieving 41% of the theoretically available resolution enhancement. Images of real-world objects are shown for visual comparison, in which the classically bound resolution is surpassed using our technically straightforward quantum-imaging scheme.

DOI
10.1364/optica.6.000347

Related papers

Quantum-enhanced imaging and sensing with spatially correlated biphotons

Ermes Toninelli

In this thesis I discuss the experimental demonstration of quantum-enhanced imaging and sensing schemes able to surpass the performance of their classical counterparts. This is achieved by exploiting the spatial properties of quantum correlated biphotons. Over the next chapters I first discuss the production and detection of quantum correlated photons using a type-I nonlinear crystal and a single-photon sensitive electron-multiplying CCD camera. I then provide a simple yet powerful description of the spatially resolved detection of biphotons, allowing to accurately model and assess the performance of the quantum-enhanced schemes featured in this thesis. These consist of a shadow-sensing and an imaging scheme able to respectively beat the shot-noise-limit in the optical measurement of the position of a shadow and the diffraction limit in the full-field imaging of real-world objects. A combination of simulated and experimental results are used to investigate both the achieved and theoretically available quantum advantage. Optical losses and detector noise are found to limit the better-than-classical performance of the schemes, which rely on the ability to jointly detect an as high as possible number of spatially correlated biphotons.

•Jan 1, 2020•0 citations

Super-Resolution Quantum Imaging at the Heisenberg Limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

Conference on Lasers and Electro-Optics•Jan 1, 2018•9 citations

Super-resolution quantum imaging at the Heisenberg limit (Conference Presentation)

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini +3 more

The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.

SPIE Quantum Technologies•May 29, 2018•0 citations

Super-resolution quantum imaging at the Heisenberg limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated $N$-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of $1/N$. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

arXiv:1712.02200•Optica•Sep 20, 2018•107 citations

Resolution in Two-Photon Imaging: A Local Manifestation of Entanglement

Thomas Gregory, Ermes Toninelli, Paul‐Antoine Moreau +6 more

High Resolution Image Download MS PowerPoint Slide The resolution of a classical imaging system is limited by diffraction. This limit can be overcome, for example, by implementing various forms of localization microscopy in which the center of a fluorescence distribution is estimated to an accuracy scaling with the square root of the number of detected photons, N . In quantum imaging the object can be illuminated using correlated photon-pairs, leading early work to suggest that a 2 improvement could be obtained as a result of averaging the position of N = 2 events. However, similar to quantum lithography, which relies upon quantum illumination using entangled photon-pairs and two-photon absorption, the minimum resolvable feature size is reduced by a factor of 2, not just 2 . Quantum imaging schemes can also lead to a factor of 2 improvement. By using a similar source of correlated photon-pairs to illuminate an object, a single-photon sensitive camera to detect the photon-pairs, and an image processing algorithm to record and sum the bisector positions of the transmitted photon-pairs, we realize a similar factor of ×2 improvement in image resolution, surpassing that of most earlier quantum imaging work.

ACS Photonics•Sep 27, 2025•3 citations

Microscopy using quantum sources of illumination

Miles J. Padgett

We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)

Photonics for Quantum (PfQ)•Aug 27, 2021•0 citations
The spatial resolution of an optical system is limited by diffraction. Various schemes have been proposed to achieve resolution enhancement by employing either a scanning source/detector configuration or a two-photon response of the object. Here, we experimentally demonstrate a full-field resolution-enhancing scheme, based on the centroid estimation of spatially quantum-correlated biphotons. Our standard-quantum-limited scheme is able to image a general non-fluorescing object, using low-energy and low-intensity infrared illumination (i.e., with <0.001 photon per pixel per frame at 710 nm), achieving 41% of the theoretically available resolution enhancement. Images of real-world objects are shown for visual comparison, in which the classically bound resolution is surpassed using our technically straightforward quantum-imaging scheme.
In this thesis I discuss the experimental demonstration of quantum-enhanced imaging and sensing schemes able to surpass the performance of their classical counterparts. This is achieved by exploiting the spatial properties of quantum correlated biphotons. Over the next chapters I first discuss the production and detection of quantum correlated photons using a type-I nonlinear crystal and a single-photon sensitive electron-multiplying CCD camera. I then provide a simple yet powerful description of the spatially resolved detection of biphotons, allowing to accurately model and assess the performance of the quantum-enhanced schemes featured in this thesis. These consist of a shadow-sensing and an imaging scheme able to respectively beat the shot-noise-limit in the optical measurement of the position of a shadow and the diffraction limit in the full-field imaging of real-world objects. A combination of simulated and experimental results are used to investigate both the achieved and theoretically available quantum advantage. Optical losses and detector noise are found to limit the better-than-classical performance of the schemes, which rely on the ability to jointly detect an as high as possible number of spatially correlated biphotons.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated NNN-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N1/N1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
High Resolution Image Download MS PowerPoint Slide The resolution of a classical imaging system is limited by diffraction. This limit can be overcome, for example, by implementing various forms of localization microscopy in which the center of a fluorescence distribution is estimated to an accuracy scaling with the square root of the number of detected photons, N . In quantum imaging the object can be illuminated using correlated photon-pairs, leading early work to suggest that a 2 improvement could be obtained as a result of averaging the position of N = 2 events. However, similar to quantum lithography, which relies upon quantum illumination using entangled photon-pairs and two-photon absorption, the minimum resolvable feature size is reduced by a factor of 2, not just 2 . Quantum imaging schemes can also lead to a factor of 2 improvement. By using a similar source of correlated photon-pairs to illuminate an object, a single-photon sensitive camera to detect the photon-pairs, and an image processing algorithm to record and sum the bisector positions of the transmitted photon-pairs, we realize a similar factor of ×2 improvement in image resolution, surpassing that of most earlier quantum imaging work.
We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)