Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SPIE Quantum Technologies

Super-resolution quantum imaging at the Heisenberg limit (Conference Presentation)

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini, Majid Zarghami, Matteo Perenzoni, André Stefanov

Published May 29, 2018• 0 citations
Publisher

Abstract

The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.

DOI
10.1117/12.2309773

Related papers

Super-Resolution Quantum Imaging at the Heisenberg Limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

Conference on Lasers and Electro-Optics•Jan 1, 2018•12 citations

Super-resolution with Fourier measurements

S. A. Wadood, Shaurya Aarav, Kevin Liang +1 more

Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect alignment with the centroid of the object. Both inhibit the practical application of these methods, as uniform motion and/or relative jitter destroy their assumptions. Here, we show that measuring intensity in the Fourier plane enables super-resolution without any of the issues of image-based methods. We start with the shift-invariance of the Fourier transform and the observation that the two-point position problem ${x_1,x_2}$ in the near field corresponds to the single-point wavenumber problem $k\ =2π/(x_2-x_1)$ in the far field. We consider the full range of mutual coherence and show that for fully coherent sources, the Fourier method saturates the quantum limit, i.e. it gives the best possible measurement. Similar results hold for sub-Rayleigh constellations of $N$ sources, which can act collectively as a spatially averaged metasurface and/or individually as elements of a phased-array antenna. The theory paves the way to merge Fourier optics with super-resolution techniques, enabling experimental devices that are both simpler and more robust than previous designs.

physics.opticsCross-listedarXiv:2511.06098•Nov 11, 2025•2 citations

Super-resolution quantum imaging at the Heisenberg limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated $N$-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of $1/N$. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

arXiv:1712.02200•Optica•Sep 20, 2018•121 citations

Resolution-enhanced quantum imaging by centroid estimation of biphotons

Ermes Toninelli, Paul‐Antoine Moreau, Thomas Gregory +4 more

The spatial resolution of an optical system is limited by diffraction.Various schemes have been proposed to achieve resolution enhancement by employing either a scanning source/detector configuration or a two-photon response of the object.Here, we experimentally demonstrate a full-field resolution-enhancing scheme, based on the centroid estimation of spatially quantum-correlated biphotons.Our standard-quantum-limited scheme is able to image a general non-fluorescing object, using low-energy and low-intensity infrared illumination (i.e., with <0.001 photon per pixel per frame at 710 nm), achieving 41% of the theoretically available resolution enhancement.Images of real-world objects are shown for visual comparison, in which the classically bound resolution is surpassed using our technically straightforward quantum-imaging scheme.

Optica•Mar 11, 2019•100 citations

基于质心法的高分辨率高探测效率N光子纠缠N00N态超分辨量子成像

张黄杰 Zhang Huangjie, 陈晨远 Chen Chenyuan, Ran Hao +5 more

Objective As a breakthrough technology in recent years, super-resolution imaging has become an important research problem in computer vision and image processing and has wide practical applications in medical, biological, security, and other fields. However, classical imaging technology is limited by the diffraction resolution limit, and it is difficult to achieve resolution breakthroughs. Quantum entanglement can transcend diffraction resolution limits by sharpening spatial interference fringes based on quantum technology evolution . The entangled N00N state has been studied because it can exceed the standard quantum limit. The interference visibility of the three-photon N00N state is higher than the limit of classical spatial super-resolution, and the pattern of the N-photon entangled N00N state is N times finer than that of classical light. Thus, the N00N state can improve the resolution of the optical system by N times. However, the probability of all N photons arriving at the same location and the detection efficiency decreases exponentially with increasing N, making the advantages of the N00N state controversial. The optical centroid measurement (OCM) promotes the application of the N00N state in super-resolution imaging. This study further applies the advantages of N-photon entangled N00N state to super-resolution quantum imaging based on existing theories and technologies. This study further proposes a new quantum imaging system to improve the resolution of object imaging. Methods This study primarily adopts theoretical analysis and simulation methods. A simulation model based on the proposed quantum imaging system is created, and the resolution enhancement of our scheme is quantified by measuring the modulation transfer function (MTF). A photon source model is constructed to generate coherent photons that are irradiated onto the object and transmitted to the receiver. The centroid position of the photons is measured using the OCM method, and the point spread function (PSF) of the imaging system is calculated using the obtained simulation data. Finally, the MTF is obtained using the Fourier transform method. In addition to the theoretical analysis of the detection efficiency enhancement of N00N state by OCM, the advantages of OCM visibility are analyzed through simulation visibility. The data are obtained through model simulation, and the curve is fitted to the data point, following the visibility calculation and analysis using the fitted curve. Results and Discussions The model simulation of the proposed imaging system shows that the MTF curve decreases with the increase of spatial frequency. However, the entangled two-photon curve changes more gently than the spatially uncorrelated two-photon curve, indicating that the resolution of entangled two-photon imaging is better than that of uncorrelated two-photon imaging. Similarly, the presence of more entangled photons changes the curve at a slower pace. The resolution of (16±2)% is enhanced in the two-photon N00N entangled state, and the resolutions of 4 and 8 photons are 30±3%, and 41±2%, respectively (Fig.2 and Table 1). The results verify the feasibility of the OCM imaging scheme for N-photon entangled N00N state super-resolution imaging. Moreover, the resolution can be enhanced by increasing the number of photons. The visibilities obtained by OCM for classical light and N00N entangled light are compared. The visibility decreases significantly as the number of photons of classical light increases from 2 to 4. The visibilities of 2, 3 and 4 photons are 45±5%,17±4%, and 12±2%, respectively, whereas the visibility obtained by OCM for N00N entangled light remains relatively constant. The obtained visibilities of 2, 3, and 4 photons are 50±4%, (44±2)%, and (42±4)%, respectively (Fig.3), achieving improved visibility. Conclusions The quantum imaging system scheme presented in this study improves the detection efficiency of N00N state by means of optical centroid measurement, and exploits the N-photon entanglement of N00N state to realize super-resolution imaging of objects. OCM does not require all photons to reach the same point in space as compared to the N-photon absorption scheme. The resolution of any number of photons can be improved by photon counting and proper post-processing, which significantly improves the detection efficiency of N00N entangled states. Moreover, the visibility of the OCM signal in N00N state is almost independent of the change in photon number N; therefore, the imaging system is suitable for higher photon numbers. The super-resolution quantum imaging system based on N-photon entanglement overcomes the problem in effectively detecting N-photon states, which improves quantum-enhanced measurement. Moreover, it is significant for Heisenberg finite phase detection and the development of super-resolution quantum imaging. Theoretically, the system can enhance N-1 times of image resolution. The prepared N00N state has high fidelity and stability. Thus, it is expected to be more commonly applied in research and promote new progress in the field of super-resolution quantum imaging.

Chinese Journal of Lasers•Jan 1, 2024•2 citations

Quantum Spatial Superresolution by Optical Centroid Measurements

Heedeuk Shin, Kam Wai Clifford Chan, Hye Jeong Chang +1 more

Quantum lithography (QL) has been suggested as a means of achieving enhanced spatial resolution for optical imaging, but its realization has been held back by the low multiphoton detection rates of recording materials. Recently, an optical centroid measurement (OCM) procedure was proposed as a way to obtain spatial resolution enhancement identical to that of QL but with higher detection efficiency (M. Tsang, Phys. Rev. Lett. 102, 253601 (2009)). Here we describe a variation of the OCM method with still higher detection efficiency based on the use of photon-number-resolving detection. We also report laboratory results for two-photon interference. We compare these results with those of the standard QL method based on multiphoton detection and show that the new method leads to superresolution but with higher detection efficiency.

arXiv:1105.2312•Physical Review Letters•Aug 19, 2011•72 citations
The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect alignment with the centroid of the object. Both inhibit the practical application of these methods, as uniform motion and/or relative jitter destroy their assumptions. Here, we show that measuring intensity in the Fourier plane enables super-resolution without any of the issues of image-based methods. We start with the shift-invariance of the Fourier transform and the observation that the two-point position problem x1,x2{x_1,x_2}x1​,x2​ in the near field corresponds to the single-point wavenumber problem k =2π/(x2−x1)k\ =2π/(x_2-x_1)k =2π/(x2​−x1​) in the far field. We consider the full range of mutual coherence and show that for fully coherent sources, the Fourier method saturates the quantum limit, i.e. it gives the best possible measurement. Similar results hold for sub-Rayleigh constellations of NNN sources, which can act collectively as a spatially averaged metasurface and/or individually as elements of a phased-array antenna. The theory paves the way to merge Fourier optics with super-resolution techniques, enabling experimental devices that are both simpler and more robust than previous designs.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated NNN-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N1/N1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
The spatial resolution of an optical system is limited by diffraction.Various schemes have been proposed to achieve resolution enhancement by employing either a scanning source/detector configuration or a two-photon response of the object.Here, we experimentally demonstrate a full-field resolution-enhancing scheme, based on the centroid estimation of spatially quantum-correlated biphotons.Our standard-quantum-limited scheme is able to image a general non-fluorescing object, using low-energy and low-intensity infrared illumination (i.e., with <0.001 photon per pixel per frame at 710 nm), achieving 41% of the theoretically available resolution enhancement.Images of real-world objects are shown for visual comparison, in which the classically bound resolution is surpassed using our technically straightforward quantum-imaging scheme.
Objective As a breakthrough technology in recent years, super-resolution imaging has become an important research problem in computer vision and image processing and has wide practical applications in medical, biological, security, and other fields. However, classical imaging technology is limited by the diffraction resolution limit, and it is difficult to achieve resolution breakthroughs. Quantum entanglement can transcend diffraction resolution limits by sharpening spatial interference fringes based on quantum technology evolution . The entangled N00N state has been studied because it can exceed the standard quantum limit. The interference visibility of the three-photon N00N state is higher than the limit of classical spatial super-resolution, and the pattern of the N-photon entangled N00N state is N times finer than that of classical light. Thus, the N00N state can improve the resolution of the optical system by N times. However, the probability of all N photons arriving at the same location and the detection efficiency decreases exponentially with increasing N, making the advantages of the N00N state controversial. The optical centroid measurement (OCM) promotes the application of the N00N state in super-resolution imaging. This study further applies the advantages of N-photon entangled N00N state to super-resolution quantum imaging based on existing theories and technologies. This study further proposes a new quantum imaging system to improve the resolution of object imaging. Methods This study primarily adopts theoretical analysis and simulation methods. A simulation model based on the proposed quantum imaging system is created, and the resolution enhancement of our scheme is quantified by measuring the modulation transfer function (MTF). A photon source model is constructed to generate coherent photons that are irradiated onto the object and transmitted to the receiver. The centroid position of the photons is measured using the OCM method, and the point spread function (PSF) of the imaging system is calculated using the obtained simulation data. Finally, the MTF is obtained using the Fourier transform method. In addition to the theoretical analysis of the detection efficiency enhancement of N00N state by OCM, the advantages of OCM visibility are analyzed through simulation visibility. The data are obtained through model simulation, and the curve is fitted to the data point, following the visibility calculation and analysis using the fitted curve. Results and Discussions The model simulation of the proposed imaging system shows that the MTF curve decreases with the increase of spatial frequency. However, the entangled two-photon curve changes more gently than the spatially uncorrelated two-photon curve, indicating that the resolution of entangled two-photon imaging is better than that of uncorrelated two-photon imaging. Similarly, the presence of more entangled photons changes the curve at a slower pace. The resolution of (16±2)% is enhanced in the two-photon N00N entangled state, and the resolutions of 4 and 8 photons are 30±3%, and 41±2%, respectively (Fig.2 and Table 1). The results verify the feasibility of the OCM imaging scheme for N-photon entangled N00N state super-resolution imaging. Moreover, the resolution can be enhanced by increasing the number of photons. The visibilities obtained by OCM for classical light and N00N entangled light are compared. The visibility decreases significantly as the number of photons of classical light increases from 2 to 4. The visibilities of 2, 3 and 4 photons are 45±5%,17±4%, and 12±2%, respectively, whereas the visibility obtained by OCM for N00N entangled light remains relatively constant. The obtained visibilities of 2, 3, and 4 photons are 50±4%, (44±2)%, and (42±4)%, respectively (Fig.3), achieving improved visibility. Conclusions The quantum imaging system scheme presented in this study improves the detection efficiency of N00N state by means of optical centroid measurement, and exploits the N-photon entanglement of N00N state to realize super-resolution imaging of objects. OCM does not require all photons to reach the same point in space as compared to the N-photon absorption scheme. The resolution of any number of photons can be improved by photon counting and proper post-processing, which significantly improves the detection efficiency of N00N entangled states. Moreover, the visibility of the OCM signal in N00N state is almost independent of the change in photon number N; therefore, the imaging system is suitable for higher photon numbers. The super-resolution quantum imaging system based on N-photon entanglement overcomes the problem in effectively detecting N-photon states, which improves quantum-enhanced measurement. Moreover, it is significant for Heisenberg finite phase detection and the development of super-resolution quantum imaging. Theoretically, the system can enhance N-1 times of image resolution. The prepared N00N state has high fidelity and stability. Thus, it is expected to be more commonly applied in research and promote new progress in the field of super-resolution quantum imaging.
Quantum lithography (QL) has been suggested as a means of achieving enhanced spatial resolution for optical imaging, but its realization has been held back by the low multiphoton detection rates of recording materials. Recently, an optical centroid measurement (OCM) procedure was proposed as a way to obtain spatial resolution enhancement identical to that of QL but with higher detection efficiency (M. Tsang, Phys. Rev. Lett. 102, 253601 (2009)). Here we describe a variation of the OCM method with still higher detection efficiency based on the use of photon-number-resolving detection. We also report laboratory results for two-photon interference. We compare these results with those of the standard QL method based on multiphoton detection and show that the new method leads to superresolution but with higher detection efficiency.