Abstract

Objective As a breakthrough technology in recent years, super-resolution imaging has become an important research problem in computer vision and image processing and has wide practical applications in medical, biological, security, and other fields. However, classical imaging technology is limited by the diffraction resolution limit, and it is difficult to achieve resolution breakthroughs. Quantum entanglement can transcend diffraction resolution limits by sharpening spatial interference fringes based on quantum technology evolution . The entangled N00N state has been studied because it can exceed the standard quantum limit. The interference visibility of the three-photon N00N state is higher than the limit of classical spatial super-resolution, and the pattern of the N-photon entangled N00N state is N times finer than that of classical light. Thus, the N00N state can improve the resolution of the optical system by N times. However, the probability of all N photons arriving at the same location and the detection efficiency decreases exponentially with increasing N, making the advantages of the N00N state controversial. The optical centroid measurement (OCM) promotes the application of the N00N state in super-resolution imaging. This study further applies the advantages of N-photon entangled N00N state to super-resolution quantum imaging based on existing theories and technologies. This study further proposes a new quantum imaging system to improve the resolution of object imaging. Methods This study primarily adopts theoretical analysis and simulation methods. A simulation model based on the proposed quantum imaging system is created, and the resolution enhancement of our scheme is quantified by measuring the modulation transfer function (MTF). A photon source model is constructed to generate coherent photons that are irradiated onto the object and transmitted to the receiver. The centroid position of the photons is measured using the OCM method, and the point spread function (PSF) of the imaging system is calculated using the obtained simulation data. Finally, the MTF is obtained using the Fourier transform method. In addition to the theoretical analysis of the detection efficiency enhancement of N00N state by OCM, the advantages of OCM visibility are analyzed through simulation visibility. The data are obtained through model simulation, and the curve is fitted to the data point, following the visibility calculation and analysis using the fitted curve. Results and Discussions The model simulation of the proposed imaging system shows that the MTF curve decreases with the increase of spatial frequency. However, the entangled two-photon curve changes more gently than the spatially uncorrelated two-photon curve, indicating that the resolution of entangled two-photon imaging is better than that of uncorrelated two-photon imaging. Similarly, the presence of more entangled photons changes the curve at a slower pace. The resolution of (16±2)% is enhanced in the two-photon N00N entangled state, and the resolutions of 4 and 8 photons are 30±3%, and 41±2%, respectively (Fig.2 and Table 1). The results verify the feasibility of the OCM imaging scheme for N-photon entangled N00N state super-resolution imaging. Moreover, the resolution can be enhanced by increasing the number of photons. The visibilities obtained by OCM for classical light and N00N entangled light are compared. The visibility decreases significantly as the number of photons of classical light increases from 2 to 4. The visibilities of 2, 3 and 4 photons are 45±5%,17±4%, and 12±2%, respectively, whereas the visibility obtained by OCM for N00N entangled light remains relatively constant. The obtained visibilities of 2, 3, and 4 photons are 50±4%, (44±2)%, and (42±4)%, respectively (Fig.3), achieving improved visibility. Conclusions The quantum imaging system scheme presented in this study improves the detection efficiency of N00N state by means of optical centroid measurement, and exploits the N-photon entanglement of N00N state to realize super-resolution imaging of objects. OCM does not require all photons to reach the same point in space as compared to the N-photon absorption scheme. The resolution of any number of photons can be improved by photon counting and proper post-processing, which significantly improves the detection efficiency of N00N entangled states. Moreover, the visibility of the OCM signal in N00N state is almost independent of the change in photon number N; therefore, the imaging system is suitable for higher photon numbers. The super-resolution quantum imaging system based on N-photon entanglement overcomes the problem in effectively detecting N-photon states, which improves quantum-enhanced measurement. Moreover, it is significant for Heisenberg finite phase detection and the development of super-resolution quantum imaging. Theoretically, the system can enhance N-1 times of image resolution. The prepared N00N state has high fidelity and stability. Thus, it is expected to be more commonly applied in research and promote new progress in the field of super-resolution quantum imaging.

DOI
10.3788/cjl230789

Related papers

Super-resolution quantum imaging at the Heisenberg limit (Conference Presentation)

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini +3 more

The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.

SPIE Quantum Technologies•May 29, 2018•0 citations

Super-Resolution Quantum Imaging at the Heisenberg Limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

Conference on Lasers and Electro-Optics•Jan 1, 2018•12 citations

Super-resolution quantum imaging at the Heisenberg limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated $N$-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of $1/N$. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

arXiv:1712.02200•Optica•Sep 20, 2018•121 citations

Quantum Spatial Superresolution by Optical Centroid Measurements

Heedeuk Shin, Kam Wai Clifford Chan, Hye Jeong Chang +1 more

Quantum lithography (QL) has been suggested as a means of achieving enhanced spatial resolution for optical imaging, but its realization has been held back by the low multiphoton detection rates of recording materials. Recently, an optical centroid measurement (OCM) procedure was proposed as a way to obtain spatial resolution enhancement identical to that of QL but with higher detection efficiency (M. Tsang, Phys. Rev. Lett. 102, 253601 (2009)). Here we describe a variation of the OCM method with still higher detection efficiency based on the use of photon-number-resolving detection. We also report laboratory results for two-photon interference. We compare these results with those of the standard QL method based on multiphoton detection and show that the new method leads to superresolution but with higher detection efficiency.

arXiv:1105.2312•Physical Review Letters•Aug 19, 2011•72 citations

Scalable Spatial Superresolution Using Entangled Photons

Lee A. Rozema, J.D. Bateman, Dylan H. Mahler +4 more

N00N states-maximally path-entangled states of N photons-exhibit spatial interference patterns sharper than any classical interference pattern. This is known as superresolution. However, even given perfectly efficient number-resolving detectors, the detection efficiency of all previous measurements of such interference would decrease exponentially with the number of photons in the N00N state, often leading to the conclusion that N00N states are unsuitable for spatial measurements. A technique known as the "optical centroid measurement" has been proposed to solve this and has been experimentally verified for photon pairs; here we present the first extension beyond two photons, measuring the superresolution fringes of two-, three-, and four-photon N00N states. Moreover, we compare the N00N-state interference to the corresponding classical superresolution interference. Although both provide the same increase in spatial frequency, the visibility of the classical fringes decreases exponentially with the number of detected photons. Our work represents an essential step forward for quantum-enhanced measurements, overcoming what was believed to be a fundamental challenge to quantum metrology.

arXiv:1312.2012•Physical Review Letters•Jun 2, 2014•118 citations

基于数字全息的量子成像技术

杨怡谦 Yang Yiqian, 曹良才 Cao Liangcai

Significance Quantum imaging (QI) harnesses quantum entanglement and correlations to achieve imaging capabilities beyond classical limits. By exploiting photon pairs, QI enables sub-shot-noise measurements, super-resolution beyond the diffraction limit, and imaging at the single-photon level with extremely low sampling ratios. These advantages make QI highly promising for biological imaging, microscopy, low-light detection, and sensing at otherwise inaccessible wavelengths. Nonetheless, practical deployment remains challenging due to complex optical setups and susceptibility to phase loss, motivating continuous progress in quantum light sources, single-photon detectors, and computational algorithms.Digital holography (DH), in contrast, is a computational imaging technique that reconstructs amplitude and phase from diffraction patterns without lenses or complex optics. DH strengths include compactness, reduced optical complexity, and the ability to capture high-dimensional information for quantitative and dynamic imaging. However, DH reconstructions are often degraded by noise and instability, particularly under low-light conditions, which limits their performance in demanding applications.By combining the resolution and noise resilience of QI with the compactness and flexibility of DH, quantum imaging techniques based on digital holography achieve efficient, high-sensitivity, and phase-resolved imaging. Featuring a large space-bandwidth product and reduced system complexity, these techniques hold strong potential for applications in microscopy, astronomy, and remote sensing. Progress Recent years have witnessed substantial progress in the development of quantum imaging techniques based on digital holography. On the light-source side, developments in spontaneous parametric down-conversion (SPDC) have enabled the generation of stable and high-quality entangled photon pairs for experimental realization (Fig. 1). Photon correlation measurements and coincidence counting have further facilitated full-field imaging, even under extremely low photon flux conditions, within both near-field and far-field diffraction models (Fig. 3). Besides, the rapid evolution of single-photon detectors has markedly enhanced photon detection efficiency and temporal resolution. The inherent trade-offs between pixel number, timing precision, and quantum efficiency underscore the complementary strengths of different detector technologies across various quantum digital holography schemes (Table 2).Beyond hardware, methodological innovations have also reshaped the field. Quantum correlation-based phase retrieval techniques now allow robust wavefront reconstruction with limited photon budgets. Polarization and entangled photon states have been successfully exploited to enrich holographic information content, offering access to vectorial and higher-dimensional imaging modalities. Adaptive optics and aberration correction strategies further mitigate aberrations and instabilities, thereby improving reconstruction fidelity under realistic conditions. At the application level, progress in biological imaging and microscopy demonstrates the unique advantages of quantum imaging techniques based on digital holography for label-free, low-light, and minimally invasive measurements.These advances collectively allow quantum imaging techniques based on digital holography to visualize and reconstruct photon states with high fidelity. High-quality images can now be obtained using fewer photons, thereby improving photon utilization efficiency, overcoming the field-of-view limitations of conventional detectors, and unlocking unique advantages such as nonlocal interference and label-free imaging. Conclusions and Prospects The fusion of quantum imaging and digital holography establishes a versatile framework that combines the quantum advantages of entanglement with the computational power of holographic reconstruction. Recent studies demonstrate that quantum imaging techniques based on digital holography achieve high-quality imaging with significantly fewer photons, thereby enhancing photon utilization efficiency and reducing detection time in sensitive applications such as biological microscopy. Moreover, the capability to reconstruct both amplitude and phase under limited photon detection conditions demonstrates a pathway to scalable quantum imaging systems that are compatible with real-world experimental constraints.This study starts from the fundamental physical mechanisms, introduces the core components involved in quantum imaging and digital holography, such as quantum light sources, quantum imaging optical path, coincidence counting, near-field and far-field diffraction models, and digital holography models. Quantum imaging techniques based on digital holography enable the visualization and reconstruction of photon states, allowing high-quality images to be obtained with fewer photons, improving photon utilization efficiency, overcoming the field-of-view limitations of detectors, and demonstrating unique advantages such as nonlocal interference and label-free imaging.With continuous advancements in devices, algorithms, and system architectures, the theory and technology of digital holography are expected to provide crucial support for the realization and application of quantum imaging. On the hardware side, the development of high-performance quantum light sources, single-photon detectors, and adaptive optical components is progressively enhancing stability, efficiency, and scalability. On the algorithmic side, the integration of advanced reconstruction strategies, such as compressive sensing, deep learning, and quantum correlation-based phase retrieval, is pushing the limits of resolution and noise resilience under photon-starved conditions. At the system level, improvements in lens-less imaging, calibration protocols, and compact optical architectures are bridging the gap between laboratory demonstrations and practical deployment. Together, these advances position digital holography not only as a powerful enabler for high-fidelity quantum imaging in fields such as microscopy, astronomy, and remote sensing, but also as a foundational technology capable of facilitating information encoding, error correction, and state characterization within emerging quantum computing platforms.

Laser & Optoelectronics Progress•Jan 1, 2026•2 citations
Objective As a breakthrough technology in recent years, super-resolution imaging has become an important research problem in computer vision and image processing and has wide practical applications in medical, biological, security, and other fields. However, classical imaging technology is limited by the diffraction resolution limit, and it is difficult to achieve resolution breakthroughs. Quantum entanglement can transcend diffraction resolution limits by sharpening spatial interference fringes based on quantum technology evolution . The entangled N00N state has been studied because it can exceed the standard quantum limit. The interference visibility of the three-photon N00N state is higher than the limit of classical spatial super-resolution, and the pattern of the N-photon entangled N00N state is N times finer than that of classical light. Thus, the N00N state can improve the resolution of the optical system by N times. However, the probability of all N photons arriving at the same location and the detection efficiency decreases exponentially with increasing N, making the advantages of the N00N state controversial. The optical centroid measurement (OCM) promotes the application of the N00N state in super-resolution imaging. This study further applies the advantages of N-photon entangled N00N state to super-resolution quantum imaging based on existing theories and technologies. This study further proposes a new quantum imaging system to improve the resolution of object imaging. Methods This study primarily adopts theoretical analysis and simulation methods. A simulation model based on the proposed quantum imaging system is created, and the resolution enhancement of our scheme is quantified by measuring the modulation transfer function (MTF). A photon source model is constructed to generate coherent photons that are irradiated onto the object and transmitted to the receiver. The centroid position of the photons is measured using the OCM method, and the point spread function (PSF) of the imaging system is calculated using the obtained simulation data. Finally, the MTF is obtained using the Fourier transform method. In addition to the theoretical analysis of the detection efficiency enhancement of N00N state by OCM, the advantages of OCM visibility are analyzed through simulation visibility. The data are obtained through model simulation, and the curve is fitted to the data point, following the visibility calculation and analysis using the fitted curve. Results and Discussions The model simulation of the proposed imaging system shows that the MTF curve decreases with the increase of spatial frequency. However, the entangled two-photon curve changes more gently than the spatially uncorrelated two-photon curve, indicating that the resolution of entangled two-photon imaging is better than that of uncorrelated two-photon imaging. Similarly, the presence of more entangled photons changes the curve at a slower pace. The resolution of (16±2)% is enhanced in the two-photon N00N entangled state, and the resolutions of 4 and 8 photons are 30±3%, and 41±2%, respectively (Fig.2 and Table 1). The results verify the feasibility of the OCM imaging scheme for N-photon entangled N00N state super-resolution imaging. Moreover, the resolution can be enhanced by increasing the number of photons. The visibilities obtained by OCM for classical light and N00N entangled light are compared. The visibility decreases significantly as the number of photons of classical light increases from 2 to 4. The visibilities of 2, 3 and 4 photons are 45±5%,17±4%, and 12±2%, respectively, whereas the visibility obtained by OCM for N00N entangled light remains relatively constant. The obtained visibilities of 2, 3, and 4 photons are 50±4%, (44±2)%, and (42±4)%, respectively (Fig.3), achieving improved visibility. Conclusions The quantum imaging system scheme presented in this study improves the detection efficiency of N00N state by means of optical centroid measurement, and exploits the N-photon entanglement of N00N state to realize super-resolution imaging of objects. OCM does not require all photons to reach the same point in space as compared to the N-photon absorption scheme. The resolution of any number of photons can be improved by photon counting and proper post-processing, which significantly improves the detection efficiency of N00N entangled states. Moreover, the visibility of the OCM signal in N00N state is almost independent of the change in photon number N; therefore, the imaging system is suitable for higher photon numbers. The super-resolution quantum imaging system based on N-photon entanglement overcomes the problem in effectively detecting N-photon states, which improves quantum-enhanced measurement. Moreover, it is significant for Heisenberg finite phase detection and the development of super-resolution quantum imaging. Theoretically, the system can enhance N-1 times of image resolution. The prepared N00N state has high fidelity and stability. Thus, it is expected to be more commonly applied in research and promote new progress in the field of super-resolution quantum imaging.
The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated NNN-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N1/N1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
Quantum lithography (QL) has been suggested as a means of achieving enhanced spatial resolution for optical imaging, but its realization has been held back by the low multiphoton detection rates of recording materials. Recently, an optical centroid measurement (OCM) procedure was proposed as a way to obtain spatial resolution enhancement identical to that of QL but with higher detection efficiency (M. Tsang, Phys. Rev. Lett. 102, 253601 (2009)). Here we describe a variation of the OCM method with still higher detection efficiency based on the use of photon-number-resolving detection. We also report laboratory results for two-photon interference. We compare these results with those of the standard QL method based on multiphoton detection and show that the new method leads to superresolution but with higher detection efficiency.
N00N states-maximally path-entangled states of N photons-exhibit spatial interference patterns sharper than any classical interference pattern. This is known as superresolution. However, even given perfectly efficient number-resolving detectors, the detection efficiency of all previous measurements of such interference would decrease exponentially with the number of photons in the N00N state, often leading to the conclusion that N00N states are unsuitable for spatial measurements. A technique known as the "optical centroid measurement" has been proposed to solve this and has been experimentally verified for photon pairs; here we present the first extension beyond two photons, measuring the superresolution fringes of two-, three-, and four-photon N00N states. Moreover, we compare the N00N-state interference to the corresponding classical superresolution interference. Although both provide the same increase in spatial frequency, the visibility of the classical fringes decreases exponentially with the number of detected photons. Our work represents an essential step forward for quantum-enhanced measurements, overcoming what was believed to be a fundamental challenge to quantum metrology.
Significance Quantum imaging (QI) harnesses quantum entanglement and correlations to achieve imaging capabilities beyond classical limits. By exploiting photon pairs, QI enables sub-shot-noise measurements, super-resolution beyond the diffraction limit, and imaging at the single-photon level with extremely low sampling ratios. These advantages make QI highly promising for biological imaging, microscopy, low-light detection, and sensing at otherwise inaccessible wavelengths. Nonetheless, practical deployment remains challenging due to complex optical setups and susceptibility to phase loss, motivating continuous progress in quantum light sources, single-photon detectors, and computational algorithms.Digital holography (DH), in contrast, is a computational imaging technique that reconstructs amplitude and phase from diffraction patterns without lenses or complex optics. DH strengths include compactness, reduced optical complexity, and the ability to capture high-dimensional information for quantitative and dynamic imaging. However, DH reconstructions are often degraded by noise and instability, particularly under low-light conditions, which limits their performance in demanding applications.By combining the resolution and noise resilience of QI with the compactness and flexibility of DH, quantum imaging techniques based on digital holography achieve efficient, high-sensitivity, and phase-resolved imaging. Featuring a large space-bandwidth product and reduced system complexity, these techniques hold strong potential for applications in microscopy, astronomy, and remote sensing. Progress Recent years have witnessed substantial progress in the development of quantum imaging techniques based on digital holography. On the light-source side, developments in spontaneous parametric down-conversion (SPDC) have enabled the generation of stable and high-quality entangled photon pairs for experimental realization (Fig. 1). Photon correlation measurements and coincidence counting have further facilitated full-field imaging, even under extremely low photon flux conditions, within both near-field and far-field diffraction models (Fig. 3). Besides, the rapid evolution of single-photon detectors has markedly enhanced photon detection efficiency and temporal resolution. The inherent trade-offs between pixel number, timing precision, and quantum efficiency underscore the complementary strengths of different detector technologies across various quantum digital holography schemes (Table 2).Beyond hardware, methodological innovations have also reshaped the field. Quantum correlation-based phase retrieval techniques now allow robust wavefront reconstruction with limited photon budgets. Polarization and entangled photon states have been successfully exploited to enrich holographic information content, offering access to vectorial and higher-dimensional imaging modalities. Adaptive optics and aberration correction strategies further mitigate aberrations and instabilities, thereby improving reconstruction fidelity under realistic conditions. At the application level, progress in biological imaging and microscopy demonstrates the unique advantages of quantum imaging techniques based on digital holography for label-free, low-light, and minimally invasive measurements.These advances collectively allow quantum imaging techniques based on digital holography to visualize and reconstruct photon states with high fidelity. High-quality images can now be obtained using fewer photons, thereby improving photon utilization efficiency, overcoming the field-of-view limitations of conventional detectors, and unlocking unique advantages such as nonlocal interference and label-free imaging. Conclusions and Prospects The fusion of quantum imaging and digital holography establishes a versatile framework that combines the quantum advantages of entanglement with the computational power of holographic reconstruction. Recent studies demonstrate that quantum imaging techniques based on digital holography achieve high-quality imaging with significantly fewer photons, thereby enhancing photon utilization efficiency and reducing detection time in sensitive applications such as biological microscopy. Moreover, the capability to reconstruct both amplitude and phase under limited photon detection conditions demonstrates a pathway to scalable quantum imaging systems that are compatible with real-world experimental constraints.This study starts from the fundamental physical mechanisms, introduces the core components involved in quantum imaging and digital holography, such as quantum light sources, quantum imaging optical path, coincidence counting, near-field and far-field diffraction models, and digital holography models. Quantum imaging techniques based on digital holography enable the visualization and reconstruction of photon states, allowing high-quality images to be obtained with fewer photons, improving photon utilization efficiency, overcoming the field-of-view limitations of detectors, and demonstrating unique advantages such as nonlocal interference and label-free imaging.With continuous advancements in devices, algorithms, and system architectures, the theory and technology of digital holography are expected to provide crucial support for the realization and application of quantum imaging. On the hardware side, the development of high-performance quantum light sources, single-photon detectors, and adaptive optical components is progressively enhancing stability, efficiency, and scalability. On the algorithmic side, the integration of advanced reconstruction strategies, such as compressive sensing, deep learning, and quantum correlation-based phase retrieval, is pushing the limits of resolution and noise resilience under photon-starved conditions. At the system level, improvements in lens-less imaging, calibration protocols, and compact optical architectures are bridging the gap between laboratory demonstrations and practical deployment. Together, these advances position digital holography not only as a powerful enabler for high-fidelity quantum imaging in fields such as microscopy, astronomy, and remote sensing, but also as a foundational technology capable of facilitating information encoding, error correction, and state characterization within emerging quantum computing platforms.