Communications in Theoretical Physics

Enhancement of Sensitivity by Initial Phase Matching in SU(1,1) Interferometers*

Xiao Xiao, Hongbin Liang, Guolong Li, Xiaoguang Wang

Published Jan 1, 2019• 7 citations
Publisher

Abstract

Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.

DOI
10.1088/0253-6102/71/1/37

Related papers

Phase-matching condition for enhancement of phase sensitivity in quantum metrology

Jing Liu, Xiao-Xing Jing, Xiaoguang Wang

We find a phase-matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd (even) state in the other port. Under this condition, the Fisher information becomes maximal with respect to the relative phase of two modes, and the phase sensitivity is enhanced. For the case with photon losses, we further find that the phase-matching condition remains unchanged with a coherent state and a coherent superposition state as the input states.

arXiv:1308.4799•Physical Review A•Oct 14, 2013•152 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

Optics Express•Apr 14, 2025•7 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Jiang, Tao, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

arXiv:2410.17612•Oct 23, 2024•0 citations

Intramode-correlation-enhanced phase sensitivities in an SU(1,1) interferometer

Qian-Kun Gong, Xiu-Ling Hu, Dong Li +3 more

We theoretically derive the lower and upper bounds of quantum Fisher information (QFI) of an SU(1,1) interferometer whatever the input state chosen. According to the QFI, the crucial resource for quantum enhancement is shown to be large intramode correlations indicated by the Mandel $Q$ parameter. The subtraction of photons from the squeezed vacuum state has the effect of increasing the average photon number of the new field state, as well as the intramode correlations. For example, for a coherent state $\ensuremath{\bigotimes}$ a squeezed vacuum state with a given fixed input mean number of photons as the input, if $p$ photons are subtracted from the squeezed-vacuum state before inputting the SU(1,1) interferometer, the phase sensitivities can be improved due to the intramode-correlation increment.

arXiv:1609.03308•Physical Review A•Sep 6, 2017•49 citations

Phase estimation of an SU(1,1) interferometer with superposition of even and odd coherent states

Abdelmajid El Maaroufi, Mouad Ait Maskour, Bouchra Maroufi +1 more

Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.

Physica Scripta•Feb 25, 2026•0 citations

Improved phase sensitivity of an SU(1,1) interferometer based on the internal single-path local squeezing operation

Qingqian Kang, Zekun Zhao, Zhao, Teng +2 more

Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these interferometers is significantly affected by photon losses, especially internal losses, which can limit the overall measurement accuracy. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the effects of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can enhance the phase sensitivity and the QFI, effectively improving the robustness of the SU(1,1) interferometer against internal and external photon losses. Additionally, a larger squeezing parameter r leads to a better performance of the interferometer.

arXiv:2410.21292•Oct 13, 2024•0 citations
Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.
We find a phase-matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd (even) state in the other port. Under this condition, the Fisher information becomes maximal with respect to the relative phase of two modes, and the phase sensitivity is enhanced. For the case with photon losses, we further find that the phase-matching condition remains unchanged with a coherent state and a coherent superposition state as the input states.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
We theoretically derive the lower and upper bounds of quantum Fisher information (QFI) of an SU(1,1) interferometer whatever the input state chosen. According to the QFI, the crucial resource for quantum enhancement is shown to be large intramode correlations indicated by the Mandel QQQ parameter. The subtraction of photons from the squeezed vacuum state has the effect of increasing the average photon number of the new field state, as well as the intramode correlations. For example, for a coherent state $\ensuremath{\bigotimes}$ a squeezed vacuum state with a given fixed input mean number of photons as the input, if ppp photons are subtracted from the squeezed-vacuum state before inputting the SU(1,1) interferometer, the phase sensitivities can be improved due to the intramode-correlation increment.
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.
Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these interferometers is significantly affected by photon losses, especially internal losses, which can limit the overall measurement accuracy. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the effects of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can enhance the phase sensitivity and the QFI, effectively improving the robustness of the SU(1,1) interferometer against internal and external photon losses. Additionally, a larger squeezing parameter r leads to a better performance of the interferometer.