Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1308.4799 · Physical Review A

Phase-matching condition for enhancement of phase sensitivity in quantum metrology

Jing Liu, Xiao-Xing Jing, Xiaoguang Wang

Published Oct 14, 2013• 152 citations
arXivHTMLPDF

Abstract

We find a phase-matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd (even) state in the other port. Under this condition, the Fisher information becomes maximal with respect to the relative phase of two modes, and the phase sensitivity is enhanced. For the case with photon losses, we further find that the phase-matching condition remains unchanged with a coherent state and a coherent superposition state as the input states.

DOI
10.1103/physreva.88.042316

Related papers

Enhancement of Sensitivity by Initial Phase Matching in SU(1,1) Interferometers*

Xiao Xiao, Hongbin Liang, Guolong Li +1 more

Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.

Communications in Theoretical Physics•Jan 1, 2019•7 citations

Phase-Matching Condition for Superpositions of Coherent States in a Mach-Zehnder Interferometer

Xiang Zhao, Luyi Shen, Xiao-Xing Jing +2 more

We discussed the phase-matching condition of the input states for a specific Mach-Zehnder interferometer to enhance the phase sensitivity. The input states are a coherent state and a superposition of coherent states. For both cases with and without photon losses, the phase-matching condition to enhance phase sensitivity is found to be unchanged no matter the input state has parity or not.

•Dec 14, 2014•0 citations

Maximal quantum Fisher information for phase estimation without initial parity

Xu Yu, Xiang Zhao, Luyi Shen +3 more

Mach-Zehnder interferometer is a common device in quantum phase estimation and the photon losses in it are an important issue for achieving a high phase accuracy. Here we thoroughly discuss the precision limit of the phase in the Mach-Zehnder interferometer with a coherent state and a superposition of coherent states as input states. By providing a general analytical expression of quantum Fisher information, the phase-matching condition and optimal initial parity are given. Especially, in the photon loss scenario, the sensitivity behaviors are analyzed and specific strategies are provided to restore the phase accuracies for symmetric and asymmetric losses.

arXiv:1412.4325•Optics Express•Jun 12, 2018•34 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

Optimal Mach-Zehnder phase sensitivity with Gaussian states

Stefan Ataman

We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in order to maximize the quantum Fisher information. Realistic detection schemes are described and their performance compared with respect to the quantum Cram\'er-Rao bound. The core of this paper discusses in detail the most general Gaussian input state, without any a priori parameter restrictions. Prioritizing the maximization of various terms in the quantum Fisher information has the consequence of imposing the input phase-matching conditions. We discuss in detail when each scenario yields an optimal performance. Realistic detection scenarios are also considered and their performance compared to the theoretical optimum. The impact of the beam splitter types employed on the optimum phase-matching conditions is also discussed. We find a number of potentially interesting advantages of these states over the coherent plus squeezed vacuum input case.

arXiv:1912.04018•Physical Review A•Dec 13, 2019•38 citations

Quantum-enhanced super-sensitivity of a Mach–Zehnder interferometer with superposition of Schrödinger’s cat-like state and Fock state as inputs using a two-channel detection

Gaurav K. Shukla, Karunesh Kumar Mishra, Dhiraj Yadav +2 more

We study the improvement in the phase sensitivity of a Mach–Zehnder interferometer using the superposition of Schrödinger’s cat-like state with the Fock state (SCFS) and the coherent state as inputs. With this setup, we examine the effect on phase sensitivity of the interferometer using a two-channel detection (TCD) scheme [ Opt. Express 29 , 95 ( 2021 ) OPEXFF 1094-4087 10.1364/OE.413391 ] in which we take the optimal combination of the intensities of both output ports. We find better phase sensitivity under some conditions for this setup as compared to other known combinations of inputs such as squeezed vacuum and coherent states, vacuum and coherent states, etc. Therefore, we expect that the SCFS may be an alternative nonclassical resource for improvement in the phase sensitivity of a Mach–Zehnder interferometer, having potential application in quantum sensing.

Journal of the Optical Society of America B•Nov 11, 2021•20 citations
We find a phase-matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd (even) state in the other port. Under this condition, the Fisher information becomes maximal with respect to the relative phase of two modes, and the phase sensitivity is enhanced. For the case with photon losses, we further find that the phase-matching condition remains unchanged with a coherent state and a coherent superposition state as the input states.
Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.
Mach-Zehnder interferometer is a common device in quantum phase estimation and the photon losses in it are an important issue for achieving a high phase accuracy. Here we thoroughly discuss the precision limit of the phase in the Mach-Zehnder interferometer with a coherent state and a superposition of coherent states as input states. By providing a general analytical expression of quantum Fisher information, the phase-matching condition and optimal initial parity are given. Especially, in the photon loss scenario, the sensitivity behaviors are analyzed and specific strategies are provided to restore the phase accuracies for symmetric and asymmetric losses.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in order to maximize the quantum Fisher information. Realistic detection schemes are described and their performance compared with respect to the quantum Cram\'er-Rao bound. The core of this paper discusses in detail the most general Gaussian input state, without any a priori parameter restrictions. Prioritizing the maximization of various terms in the quantum Fisher information has the consequence of imposing the input phase-matching conditions. We discuss in detail when each scenario yields an optimal performance. Realistic detection scenarios are also considered and their performance compared to the theoretical optimum. The impact of the beam splitter types employed on the optimum phase-matching conditions is also discussed. We find a number of potentially interesting advantages of these states over the coherent plus squeezed vacuum input case.
We study the improvement in the phase sensitivity of a Mach–Zehnder interferometer using the superposition of Schrödinger’s cat-like state with the Fock state (SCFS) and the coherent state as inputs. With this setup, we examine the effect on phase sensitivity of the interferometer using a two-channel detection (TCD) scheme [ Opt. Express 29 , 95 ( 2021 ) OPEXFF 1094-4087 10.1364/OE.413391 ] in which we take the optimal combination of the intensities of both output ports. We find better phase sensitivity under some conditions for this setup as compared to other known combinations of inputs such as squeezed vacuum and coherent states, vacuum and coherent states, etc. Therefore, we expect that the SCFS may be an alternative nonclassical resource for improvement in the phase sensitivity of a Mach–Zehnder interferometer, having potential application in quantum sensing.