Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Phase-Matching Condition for Superpositions of Coherent States in a Mach-Zehnder Interferometer

Xiang Zhao, Luyi Shen, Xiao-Xing Jing, Jing Liu, Xiaoguang Wang

Published Dec 14, 2014• 0 citations
OpenAlex

Abstract

We discussed the phase-matching condition of the input states for a specific Mach-Zehnder interferometer to enhance the phase sensitivity. The input states are a coherent state and a superposition of coherent states. For both cases with and without photon losses, the phase-matching condition to enhance phase sensitivity is found to be unchanged no matter the input state has parity or not.

Related papers

Phase-matching condition for enhancement of phase sensitivity in quantum metrology

Jing Liu, Xiao-Xing Jing, Xiaoguang Wang

We find a phase-matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd (even) state in the other port. Under this condition, the Fisher information becomes maximal with respect to the relative phase of two modes, and the phase sensitivity is enhanced. For the case with photon losses, we further find that the phase-matching condition remains unchanged with a coherent state and a coherent superposition state as the input states.

arXiv:1308.4799•Physical Review A•Oct 14, 2013•152 citations

Maximal quantum Fisher information for phase estimation without initial parity

Xu Yu, Xiang Zhao, Luyi Shen +3 more

Mach-Zehnder interferometer is a common device in quantum phase estimation and the photon losses in it are an important issue for achieving a high phase accuracy. Here we thoroughly discuss the precision limit of the phase in the Mach-Zehnder interferometer with a coherent state and a superposition of coherent states as input states. By providing a general analytical expression of quantum Fisher information, the phase-matching condition and optimal initial parity are given. Especially, in the photon loss scenario, the sensitivity behaviors are analyzed and specific strategies are provided to restore the phase accuracies for symmetric and asymmetric losses.

arXiv:1412.4325•Optics Express•Jun 12, 2018•34 citations

Quantum-enhanced super-sensitivity of a Mach–Zehnder interferometer with superposition of Schrödinger’s cat-like state and Fock state as inputs using a two-channel detection

Gaurav K. Shukla, Karunesh Kumar Mishra, Dhiraj Yadav +2 more

We study the improvement in the phase sensitivity of a Mach–Zehnder interferometer using the superposition of Schrödinger’s cat-like state with the Fock state (SCFS) and the coherent state as inputs. With this setup, we examine the effect on phase sensitivity of the interferometer using a two-channel detection (TCD) scheme [ Opt. Express 29 , 95 ( 2021 ) OPEXFF 1094-4087 10.1364/OE.413391 ] in which we take the optimal combination of the intensities of both output ports. We find better phase sensitivity under some conditions for this setup as compared to other known combinations of inputs such as squeezed vacuum and coherent states, vacuum and coherent states, etc. Therefore, we expect that the SCFS may be an alternative nonclassical resource for improvement in the phase sensitivity of a Mach–Zehnder interferometer, having potential application in quantum sensing.

Journal of the Optical Society of America B•Nov 11, 2021•20 citations

Phase sensitivity of two nonlinear interferometers with inputting entangled coherent states

Chaoping Wei, Xiao‐Yu Hu, Ya‐Fei Yu +1 more

We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.

Chinese Physics B•Apr 1, 2016•16 citations

Optimal Mach-Zehnder phase sensitivity with Gaussian states

Stefan Ataman

We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in order to maximize the quantum Fisher information. Realistic detection schemes are described and their performance compared with respect to the quantum Cram\'er-Rao bound. The core of this paper discusses in detail the most general Gaussian input state, without any a priori parameter restrictions. Prioritizing the maximization of various terms in the quantum Fisher information has the consequence of imposing the input phase-matching conditions. We discuss in detail when each scenario yields an optimal performance. Realistic detection scenarios are also considered and their performance compared to the theoretical optimum. The impact of the beam splitter types employed on the optimum phase-matching conditions is also discussed. We find a number of potentially interesting advantages of these states over the coherent plus squeezed vacuum input case.

arXiv:1912.04018•Physical Review A•Dec 13, 2019•38 citations

High-sensitivity phase estimation with a two-mode squeezed coherent state based on a Mach–Zehnder interferometer

Pengxiang Ruan, Jun Liu, Chenlu Li +3 more

Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.

Chinese Physics B•Jul 28, 2025•0 citations
We discussed the phase-matching condition of the input states for a specific Mach-Zehnder interferometer to enhance the phase sensitivity. The input states are a coherent state and a superposition of coherent states. For both cases with and without photon losses, the phase-matching condition to enhance phase sensitivity is found to be unchanged no matter the input state has parity or not.
We find a phase-matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd (even) state in the other port. Under this condition, the Fisher information becomes maximal with respect to the relative phase of two modes, and the phase sensitivity is enhanced. For the case with photon losses, we further find that the phase-matching condition remains unchanged with a coherent state and a coherent superposition state as the input states.
Mach-Zehnder interferometer is a common device in quantum phase estimation and the photon losses in it are an important issue for achieving a high phase accuracy. Here we thoroughly discuss the precision limit of the phase in the Mach-Zehnder interferometer with a coherent state and a superposition of coherent states as input states. By providing a general analytical expression of quantum Fisher information, the phase-matching condition and optimal initial parity are given. Especially, in the photon loss scenario, the sensitivity behaviors are analyzed and specific strategies are provided to restore the phase accuracies for symmetric and asymmetric losses.
We study the improvement in the phase sensitivity of a Mach–Zehnder interferometer using the superposition of Schrödinger’s cat-like state with the Fock state (SCFS) and the coherent state as inputs. With this setup, we examine the effect on phase sensitivity of the interferometer using a two-channel detection (TCD) scheme [ Opt. Express 29 , 95 ( 2021 ) OPEXFF 1094-4087 10.1364/OE.413391 ] in which we take the optimal combination of the intensities of both output ports. We find better phase sensitivity under some conditions for this setup as compared to other known combinations of inputs such as squeezed vacuum and coherent states, vacuum and coherent states, etc. Therefore, we expect that the SCFS may be an alternative nonclassical resource for improvement in the phase sensitivity of a Mach–Zehnder interferometer, having potential application in quantum sensing.
We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.
We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in order to maximize the quantum Fisher information. Realistic detection schemes are described and their performance compared with respect to the quantum Cram\'er-Rao bound. The core of this paper discusses in detail the most general Gaussian input state, without any a priori parameter restrictions. Prioritizing the maximization of various terms in the quantum Fisher information has the consequence of imposing the input phase-matching conditions. We discuss in detail when each scenario yields an optimal performance. Realistic detection scenarios are also considered and their performance compared to the theoretical optimum. The impact of the beam splitter types employed on the optimum phase-matching conditions is also discussed. We find a number of potentially interesting advantages of these states over the coherent plus squeezed vacuum input case.
Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.