Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Measurement of the spatial magnetic field distribution in a single large spin-exchange relaxation-free vapor cell

Alexander Gusarov, Andrei Ben-Amar Baranga, David Levron, R. Shuker

Published Jan 1, 2019• 7 citations
Publisher
DOI
10.1007/s00340-018-7130-7

Related papers

High spatial resolution multi-channel optically pumped atomic magnetometer based on a spatial light modulator

Xiujie Fang, Kai Wei, Tian Zhao +5 more

Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.

Optics Express•Aug 14, 2020•48 citations

High-spatial-resolution monitoring of strong magnetic field using Rb vapor nanometric-thin cell

G. Hakhumyan, Claude Leroy, Y. Pashayan-Leroy +2 more

arXiv:1103.1228•Optics Communications•Apr 30, 2011•25 citations

Optimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer

Yaxiang Wang, Ge Jin, Junjian Tang +4 more

We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89 fT / Hz in the single-beam configuration, with an active measurement volume of 3 × 3 × 3~mm3.

Optics Express•Dec 15, 2021•46 citations

Magnetic field detection and imaging with atomic Rb vapor

Eugeniy E. Mikhailov, Kevin C. Cox, Irina V. Novikova +2 more

APS•Mar 1, 2010•0 citations

Towards a multi-channel zero-field optically pumped magnetometer for imaging

Ronja Rasser, Peter A. Koss, Svenja A. Knappe +1 more

Abstract We present a design for a multi-channel optically pumped zero-field magnetometer utilizing a 200-μm-thick Rubidium vapor cell. The vapor cell and its housing are designed to reduce the minimal distance between a magnetic sample and the sensing volume to about 1 mm, to optimize the effective spatial resolution. The thin vapor cell, filled with 2 atm of nitrogen as a buffer gas reduces the volume across which the magnetic field is averaged. The vapor cell is fully illuminated by a single laser beam, and the transmitted light is imaged onto a 4 x 4 photodiode array, allowing for simultaneous measurement of a magnetic field distribution with up to 16 channels. The performance of the magnetometer is studied for all channels. It is shown that the sensor can operate in the spin-exchange relaxation-free regime with a projected photon-shot noise limited noise floor of about 1 pT/Hz1/2 for a sensitive voxel size of approximately 600 μm x 600 μm x 200 μm.

EPJ Quantum Technology•Aug 13, 2025•7 citations

Suppression of spin-exchange relaxation in Bell-Bloom magnetometer

Chi Fang, Liwei Jiang, Jiali Liu +6 more

Measurement•Sep 10, 2024•14 citations
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.
We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89 fT / Hz in the single-beam configuration, with an active measurement volume of 3 × 3 × 3~mm3.
Abstract We present a design for a multi-channel optically pumped zero-field magnetometer utilizing a 200-μm-thick Rubidium vapor cell. The vapor cell and its housing are designed to reduce the minimal distance between a magnetic sample and the sensing volume to about 1 mm, to optimize the effective spatial resolution. The thin vapor cell, filled with 2 atm of nitrogen as a buffer gas reduces the volume across which the magnetic field is averaged. The vapor cell is fully illuminated by a single laser beam, and the transmitted light is imaged onto a 4 x 4 photodiode array, allowing for simultaneous measurement of a magnetic field distribution with up to 16 channels. The performance of the magnetometer is studied for all channels. It is shown that the sensor can operate in the spin-exchange relaxation-free regime with a projected photon-shot noise limited noise floor of about 1 pT/Hz1/2 for a sensitive voxel size of approximately 600 μm x 600 μm x 200 μm.