On the Development of an AC-Quantum Voltmeter

Ricardo Iuzzolino, Marcos Eduardo Bierzychudek, L. Palafox, Ralf Behr, Agustin Tedesco

Published Jul 1, 2018• 4 citations
Publisher

Abstract

This paper presents an AC-Quantum voltmeter based on a 1 V programmable Josephson array, a purpose-built sigma-delta digitizer, a clock generator and a custom AC bias source. The highlights of this system are briefly described and supported by preliminary measurements.
DOI
10.1109/cpem.2018.8500894

Related papers

Investigation of binary Josephson arrays for arbitrary waveform synthesis

Peter Kleinschmidt, P. Patel, Jonathan M. J. Williams +1 more

Arrays of Josephson junctions have been used successfully for many years as the primary standard of voltage. A recent development has been the fabrication of arrays, based on non-hysteretic Josephson junctions, which allows the voltage output to be changed almost instantaneously. When these arrays are divided into binary segments a ‘digital-to-analogue converter’ with quantum accuracy is created. The properties of two types of array, a SINIS array, using intrinsic shunting of the Josephson junctions, and a SIS array with external, on-chip shunting have been investigated. The accuracy of the generated voltages and AC properties of the arrays when driven with a purpose-built, programmable current bias source are discussed. It is anticipated that a Josephson standard having waveforms with calculable rms values of AC voltage will soon be available.

IEE Proceedings - Science Measurement and Technology•Nov 4, 2002•34 citations

AC and DC voltages from a Josephson arbitrary waveform synthesizer

Samuel P. Benz, Charles J. Burroughs, Paul D. Dresselhaus +1 more

We have synthesized and measured ac and dc voltages using a Josephson arbitrary waveform synthesizer. On-chip filtering has enabled the first practical operating margins for ac and arbitrary waveforms. Using a digital voltmeter, we demonstrate the operating margins and linearity of 101 synthesized dc voltages and confirm the flatness of a single voltage step. We present the first ac-dc and ac-ac voltage measurements of the synthesizer at 3.65 mV using an ac-dc thermal transfer standard. This quantum-based standard source can be used to measure the ac-dc difference of thermal transfer standards at small voltages.

IEEE Transactions on Instrumentation and Measurement•Apr 1, 2001•44 citations

Josephson voltage standards

Clark A. Hamilton

This paper reviews the development and use of Josephson voltage standards over the last 30 years, including classical dc standards, programmable standards based on binary weighted arrays, pulse-driven delta–sigma standards for ac wave-form synthesis, and single-flux-quantum voltage multipliers.

Review of Scientific Instruments•Oct 1, 2000•202 citations

A modular and customizable open-source package for quantum voltage standards operation and control

Paolo Durandetto, A. Sosso

This paper presents an open-source package developed in Python that controls and drives a programmable Josephson array to synthesize dc and ac quantum-accurate voltages. Programmable arrays are devices subdivided into independent subsections, each counting a number of series connected Josephson junctions that follows a binary sequence (1, 2, 4, 8, …) to control the output voltage. Our software allows to independently measure the current-voltage characteristics of each subsection by means of a set of arbitrary waveform generators and a nanovoltmeter that measures the voltage across the whole array with high sensitivity. A quantization test tool is also provided to check with sub-microvolt resolution whether the array is operating on its quantum margins. The code is modular and easily expandable with the support of many libraries, allowing prompt reconfiguration for different calibration and testing purposes. It is aimed at being a starting point for cooperation between National Metrology Institutes towards the realization of a shared quantum voltage calibration infrastructure.

PLoS ONE•Dec 17, 2018•3 citations

A dry-cooled AC quantum voltmeter

M. Schubert, M. Starkloff, Katja Peiselt +9 more

Abstract The paper describes a dry-cooled AC quantum voltmeter system operated up to kilohertz frequencies and 7 V rms. A 10 V programmable Josephson voltage standard (PJVS) array was installed on a pulse tube cooler (PTC) driven with a 4 kW air-cooled compressor. The operating margins at 70 GHz frequencies were investigated in detail and found to exceed 1 mA Shapiro step width. A key factor for the successful chip operation was the low on-chip power consumption of 65 mW in total. A thermal interface between PJVS chip and PTC cold stage was used to avoid a significant chip overheating. By installing the cryocooled PJVS array into an AC quantum voltmeter setup, several calibration measurements of dc standards and calibrator ac voltages up to 2 kHz frequencies were carried out to demonstrate the full functionality. The results are discussed and compared to systems with standard liquid helium cooling. For dc voltages, a direct comparison measurement between the dry-cooled AC quantum voltmeter and a liquid-helium based 10 V PJVS shows an agreement better than 1 part in 10 10 .

Superconductor Science and Technology•Sep 15, 2016•14 citations

Analog-to-digital conversion for low-frequency waveforms based on the Josephson voltage standard

Mun-Seog Kim, Kyu‐Tae Kim, Wan-Seop Kim +2 more

A waveform synthesizer adopting a superconductor–normal metal–superconductor junction array has been developed, which can generate arbitrary stepwise waveforms with a number of quantum-voltage steps up to 1 V level amplitude. As an application of the synthesizer, we have built a sampling voltmeter that measures the differential voltages between a sinusoidal waveform produced by a semiconductor-based ac source and the Josephson waveforms. We carried out extensive sampling measurements for a 50 Hz sine wave with 1 V amplitude, applying sampling apertures in the range of 55 µs ⩽ t a ⩽ 130 µs and using Josephson waveforms with 32, 60, 80 and 100 quantum steps. From the measurements, the amplitude of the ac waveform was determined with a type A uncertainty ( k = 2) of 0.15 µV. Also, we elucidated how the phase jitter in the ac waveform is reflected in the overall uncertainty for the measurements. The type B uncertainty due to the jitter is at least one order of magnitude smaller than the type A uncertainty.

Measurement Science and Technology•Sep 24, 2010•38 citations
Arrays of Josephson junctions have been used successfully for many years as the primary standard of voltage. A recent development has been the fabrication of arrays, based on non-hysteretic Josephson junctions, which allows the voltage output to be changed almost instantaneously. When these arrays are divided into binary segments a ‘digital-to-analogue converter’ with quantum accuracy is created. The properties of two types of array, a SINIS array, using intrinsic shunting of the Josephson junctions, and a SIS array with external, on-chip shunting have been investigated. The accuracy of the generated voltages and AC properties of the arrays when driven with a purpose-built, programmable current bias source are discussed. It is anticipated that a Josephson standard having waveforms with calculable rms values of AC voltage will soon be available.
We have synthesized and measured ac and dc voltages using a Josephson arbitrary waveform synthesizer. On-chip filtering has enabled the first practical operating margins for ac and arbitrary waveforms. Using a digital voltmeter, we demonstrate the operating margins and linearity of 101 synthesized dc voltages and confirm the flatness of a single voltage step. We present the first ac-dc and ac-ac voltage measurements of the synthesizer at 3.65 mV using an ac-dc thermal transfer standard. This quantum-based standard source can be used to measure the ac-dc difference of thermal transfer standards at small voltages.
This paper presents an open-source package developed in Python that controls and drives a programmable Josephson array to synthesize dc and ac quantum-accurate voltages. Programmable arrays are devices subdivided into independent subsections, each counting a number of series connected Josephson junctions that follows a binary sequence (1, 2, 4, 8, …) to control the output voltage. Our software allows to independently measure the current-voltage characteristics of each subsection by means of a set of arbitrary waveform generators and a nanovoltmeter that measures the voltage across the whole array with high sensitivity. A quantization test tool is also provided to check with sub-microvolt resolution whether the array is operating on its quantum margins. The code is modular and easily expandable with the support of many libraries, allowing prompt reconfiguration for different calibration and testing purposes. It is aimed at being a starting point for cooperation between National Metrology Institutes towards the realization of a shared quantum voltage calibration infrastructure.
Abstract The paper describes a dry-cooled AC quantum voltmeter system operated up to kilohertz frequencies and 7 V rms. A 10 V programmable Josephson voltage standard (PJVS) array was installed on a pulse tube cooler (PTC) driven with a 4 kW air-cooled compressor. The operating margins at 70 GHz frequencies were investigated in detail and found to exceed 1 mA Shapiro step width. A key factor for the successful chip operation was the low on-chip power consumption of 65 mW in total. A thermal interface between PJVS chip and PTC cold stage was used to avoid a significant chip overheating. By installing the cryocooled PJVS array into an AC quantum voltmeter setup, several calibration measurements of dc standards and calibrator ac voltages up to 2 kHz frequencies were carried out to demonstrate the full functionality. The results are discussed and compared to systems with standard liquid helium cooling. For dc voltages, a direct comparison measurement between the dry-cooled AC quantum voltmeter and a liquid-helium based 10 V PJVS shows an agreement better than 1 part in 10 10 .
A waveform synthesizer adopting a superconductor–normal metal–superconductor junction array has been developed, which can generate arbitrary stepwise waveforms with a number of quantum-voltage steps up to 1 V level amplitude. As an application of the synthesizer, we have built a sampling voltmeter that measures the differential voltages between a sinusoidal waveform produced by a semiconductor-based ac source and the Josephson waveforms. We carried out extensive sampling measurements for a 50 Hz sine wave with 1 V amplitude, applying sampling apertures in the range of 55 µs ⩽ t a ⩽ 130 µs and using Josephson waveforms with 32, 60, 80 and 100 quantum steps. From the measurements, the amplitude of the ac waveform was determined with a type A uncertainty ( k = 2) of 0.15 µV. Also, we elucidated how the phase jitter in the ac waveform is reflected in the overall uncertainty for the measurements. The type B uncertainty due to the jitter is at least one order of magnitude smaller than the type A uncertainty.