Measurement Science and Technology

In situ determination of alkali metal density using phase-frequency analysis on atomic magnetometers

Han Yao, Hong Zhang, Danyue Ma, Junpeng Zhao, Ming Ding

Published Aug 1, 2018• 9 citations
Publisher

Abstract

The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.

DOI
10.1088/1361-6501/aad1e0

Related papers

In-situ measurement of cell temperature by spin-relaxation rate analysis for an atomic magnetometer

Bingquan Zhao, Zhe Qi, Jianlong Wang +5 more

Alkali-metal vapor cells are the core sensing components of atomic magnetometers. To achieve high-sensitivity magnetic field measurements, the cells require heating and stabilization at high temperatures. Here, we propose an in-situ temperature measurement method for a vapor cell of an atomic magnetometer based on spin-relaxation analysis. This technique establishes a direct functional correlation between the cell temperature and the spin-relaxation rate under low pumping power conditions. Experimental validation within the temperature range of 90 °C–130 °C confirms the accuracy of this approach. We further investigate the effects of magnetic fields on measurement precision and demonstrate the long-term, high-precision capabilities of temperature detection. This non-invasive technique presents a critical advantage for precise thermal optimization of atomic magnetometers.

Chinese Physics B•Sep 17, 2025•0 citations

On-site monitoring of atomic density number for an all-optical atomic magnetometer based on atomic spin exchange relaxation

Hong Zhang, Sheng Zou, Xiyuan Chen +4 more

We present a method for monitoring the atomic density number on site based on atomic spin exchange relaxation. When the spin polarization P ≪ 1, the atomic density numbers could be estimated by measuring magnetic resonance linewidth in an applied DC magnetic field by using an all-optical atomic magnetometer. The density measurement results showed that the experimental results the theoretical predictions had a good consistency in the investigated temperature range from 413 K to 463 K, while, the experimental results were approximately 1.5 ∼ 2 times less than the theoretical predictions estimated from the saturated vapor pressure curve. These deviations were mainly induced by the radiative heat transfer efficiency, which inevitably leaded to a lower temperature in cell than the setting temperature.

Optics Express•Jul 21, 2016•21 citations

The Space Density Distribution of Alkali Metal Atoms in a SERF Atomic Magnetometer

Qiang Guo, Xuewen Li, Ning Zhang +4 more

The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.

IEEE Sensors Journal•Jan 27, 2022•13 citations

In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection

Yintao Ma, Zhixia Qiao, Yao Chen +8 more

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

Optics Express•Jan 17, 2023•6 citations

In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers

Kaifeng Yin, Binquan Zhou, Jixi Lu +4 more

Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.

IEEE Sensors Journal•Nov 30, 2021•15 citations

Real-time nondemolition measurement method for alkali vapor density and its application in a spin-exchange relaxation-free co-magnetometer

Ruigang Wang, Feng Li, Zehua Liu +3 more

This study presents a novel method for measuring the number density of K in K-Rb hybrid vapor cells using circularly polarized pump light on polarized alkali metal atoms. This proposed method eliminates the need for additional devices such as absorption spectroscopy, Faraday rotation, or resistance temperature detector technology. The modeling process involved considering wall loss, scattering loss, atomic absorption loss, and atomic saturation absorption, with experiments designed to identify the relevant parameters. The proposed method is real-time, highly stable, and a quantum nondemolition measurement that does not disrupt the spin-exchange relaxation-free (SERF) regime. Experimental results demonstrate the effectiveness of the proposed method, as the longitudinal electron spin polarization long-term stability increased by 204% and the transversal electron spin polarization long-term stability increased by 44.8%, as evaluated by the Allan variance.

Optics Express•May 30, 2023•16 citations
The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.
Alkali-metal vapor cells are the core sensing components of atomic magnetometers. To achieve high-sensitivity magnetic field measurements, the cells require heating and stabilization at high temperatures. Here, we propose an in-situ temperature measurement method for a vapor cell of an atomic magnetometer based on spin-relaxation analysis. This technique establishes a direct functional correlation between the cell temperature and the spin-relaxation rate under low pumping power conditions. Experimental validation within the temperature range of 90 °C–130 °C confirms the accuracy of this approach. We further investigate the effects of magnetic fields on measurement precision and demonstrate the long-term, high-precision capabilities of temperature detection. This non-invasive technique presents a critical advantage for precise thermal optimization of atomic magnetometers.
We present a method for monitoring the atomic density number on site based on atomic spin exchange relaxation. When the spin polarization P ≪ 1, the atomic density numbers could be estimated by measuring magnetic resonance linewidth in an applied DC magnetic field by using an all-optical atomic magnetometer. The density measurement results showed that the experimental results the theoretical predictions had a good consistency in the investigated temperature range from 413 K to 463 K, while, the experimental results were approximately 1.5 ∼ 2 times less than the theoretical predictions estimated from the saturated vapor pressure curve. These deviations were mainly induced by the radiative heat transfer efficiency, which inevitably leaded to a lower temperature in cell than the setting temperature.
The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.
This study presents a novel method for measuring the number density of K in K-Rb hybrid vapor cells using circularly polarized pump light on polarized alkali metal atoms. This proposed method eliminates the need for additional devices such as absorption spectroscopy, Faraday rotation, or resistance temperature detector technology. The modeling process involved considering wall loss, scattering loss, atomic absorption loss, and atomic saturation absorption, with experiments designed to identify the relevant parameters. The proposed method is real-time, highly stable, and a quantum nondemolition measurement that does not disrupt the spin-exchange relaxation-free (SERF) regime. Experimental results demonstrate the effectiveness of the proposed method, as the longitudinal electron spin polarization long-term stability increased by 204% and the transversal electron spin polarization long-term stability increased by 44.8%, as evaluated by the Allan variance.