Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Frequency and Time Forum

Advances in the uncertainty evaluation of a 88Sr+ single ion optical clock

P. Dubé, Bin Jian, Amar C. Vutha

Published Apr 1, 2018• 2 citations
Publisher

Abstract

We report on recent progress in the evaluation and reduction of the systematic shifts of the strontium ion clock, addressing effects such as the collisional frequency shift, the servo tracking errors, and the blackbody radiation (BBR) shift. The total uncertainty is currently dominated by the BBR field evaluation. All the other known contributions are at least one order of magnitude smaller. Experiments are underway to improve the BBR field evaluation using thermal imaging of a dummy ion trap.

DOI
10.1109/eftf.2018.8409058

Related papers

Progress towards a strontium single-ion optical clock with mHz uncertainty

P. Dubé, Bin Jian, Alan A. Madej

The strontium ion clock developed at the National Research Council of Canada has reached an uncertainty level of 5 mHz in recent years. This low level of uncertainty was achieved in great part by using methods that harness specific properties of the clock transition that allow either a very high level of cancellation or a strong suppression of frequency shifts that would otherwise dominate the uncertainty budget. The shifts controlled by these methods are the electric quadrupole shift, the tensor Stark shifts, and the micromotion shifts. With these methods in place, the main limitation to the accuracy of the clock transition frequency is the uncertainty in the evaluation of blackbody radiation (BBR) field. In this paper, we review the methods used to control the shifts to the 5 mHz level and present our plans for the evaluation of the BBR field that is expected to reduce the total uncertainty to the mHz level.

European Frequency and Time Forum•Apr 1, 2016•0 citations

Progress Towards a Cryogenic Single-ion Clock

Takahiro Tow

The accuracy of state-of-the-art optical atomic clocks has surpassed that of microwave clocks by more than two orders of magnitude. This revolution in accuracy has prompted international dialogue concerning the redefinition of the SI second away from the current cesium standard. Optical clocks employing a single trapped ion are promising candidates for realizing this redefinition as they offer exceptional fractional frequency uncertainty. However, there is still room for improvement: the leading contributions to the uncertainty of most single-ion clocks, such as the 88Sr+ clock operated by the National Research Council of Canada (NRC), are the blackbody radiation shifts and collisional frequency shifts. The uncancelled blackbody radiation shift dominates both the total shift and uncertainty of the existing room temperature strontium ion clocks. To address these sources of inaccuracy, I contributed to developing a strontium ion trap for operation at 4 K. Operating at cryogenic temperatures suppresses the blackbody radiation shift by eight orders of magnitude and collisional shifts by at least two orders of magnitude, enabling substantial improvements to the performance of single-ion clocks. The proposed cryogenic clock is capable of achieving fractional frequency uncertainty below 10−19. This thesis describes the design, construction, and evaluation of the cryogenic ion trap towards realizing a more accurate atomic clock.

•Jun 1, 2026•0 citations

Quantum projection noise limited stability and blackbody radiation shift uncertainty of NRC's Sr+atomic clock

Bin Jian, P. Dubé, Alan A. Madej

We present the current status of the Sr+optical atomic ion clock at the National Research Council of Canada including the study of the quantum projection noise (QPN) limited stability and the progress on the evaluation of the blackbody radiation (BBR) shift uncertainty. The latest QPN limited stability of NRC's Sr+ clock is 3 × 10-15at 1 sec averaging time. The fractional evaluated accuracy of the Sr+ ion clock has reached 1.2 × 10-17and is now dominated by the BBR shift uncertainty, the improved evaluation of which is currently in progress.

Conference on Precision Electromagnetic Measurements•Jul 1, 2016•0 citations

Progress on the 40Ca+ ion optical clock*

Baolin Zhang, Yao Huang, Huaqing Zhang +4 more

Progress of the 40Ca+ ion optical clock based on the 42S1/2 – 3d 2D5/2 electric quadrupole transition is reported. By setting the drive frequency to the “magic” frequency Ω 0, the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10−19 level. By precisely measuring the differential static scalar polarizability Δα 0, the uncertainty due to the blackbody radiation (BBR) shift (coefficient) is reduced to the 10−19 level. With the help of a second-order integrating servo algorithm, the uncertainty due to the servo error is reduced to the 10−18 level. The total fractional uncertainty of the 40Ca+ ion optical clock is then improved to 2.2× 10−17, whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations. The state preparation is introduced together with improvements in the pulse sequence, and furthermore, a better signal to noise ratio (SNR) and less dead time are achieved. The clock stability of a single clock is improved to 4.8 × 10 − 15 / τ ( in seconds ) .

Chinese Physics B•May 19, 2020•18 citations

87Sr optical lattice clocks at JILA

Michael J. Martin, Matthew D. Swallows, Travis Nicholson +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Evaluation of a Sr+88 Optical Clock with a Direct Measurement of the Blackbody Radiation Shift and Determination of the Clock Frequency

Martin Steinel, H. Shao, Melina Filzinger +7 more

We report on an evaluation of an optical clock that uses the ^{2}S_{1/2}→^{2}D_{5/2} transition of a single ^{88}Sr^{+} ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized sensitivity to thermal radiation. We measure the clock output frequency against an independent ^{171}Yb^{+} ion clock, based on the ^{2}S_{1/2}(F=0)→^{2}F_{7/2}(F=3) electric octupole (E3) transition, and determine the frequency ratio with a total fractional uncertainty of 2.3×10^{-17}. Relying on a previous measurement of the ^{171}Yb^{+} (E3) clock frequency, we find the absolute frequency of the ^{88}Sr^{+} clock transition to be 444 779 044 095 485.277(59) Hz. Our result reduces the uncertainty by a factor of 3 compared with the previously most accurate measurement and may help to resolve so far inconsistent determinations of this value. We also show that for three simultaneously interrogated ^{88}Sr^{+} ions, the increased number causes the expected improvement of the short-term frequency instability of the optical clock without degrading its systematic uncertainty.

arXiv:2212.08687•Physical Review Letters•Aug 23, 2023•29 citations
We report on recent progress in the evaluation and reduction of the systematic shifts of the strontium ion clock, addressing effects such as the collisional frequency shift, the servo tracking errors, and the blackbody radiation (BBR) shift. The total uncertainty is currently dominated by the BBR field evaluation. All the other known contributions are at least one order of magnitude smaller. Experiments are underway to improve the BBR field evaluation using thermal imaging of a dummy ion trap.
The strontium ion clock developed at the National Research Council of Canada has reached an uncertainty level of 5 mHz in recent years. This low level of uncertainty was achieved in great part by using methods that harness specific properties of the clock transition that allow either a very high level of cancellation or a strong suppression of frequency shifts that would otherwise dominate the uncertainty budget. The shifts controlled by these methods are the electric quadrupole shift, the tensor Stark shifts, and the micromotion shifts. With these methods in place, the main limitation to the accuracy of the clock transition frequency is the uncertainty in the evaluation of blackbody radiation (BBR) field. In this paper, we review the methods used to control the shifts to the 5 mHz level and present our plans for the evaluation of the BBR field that is expected to reduce the total uncertainty to the mHz level.
The accuracy of state-of-the-art optical atomic clocks has surpassed that of microwave clocks by more than two orders of magnitude. This revolution in accuracy has prompted international dialogue concerning the redefinition of the SI second away from the current cesium standard. Optical clocks employing a single trapped ion are promising candidates for realizing this redefinition as they offer exceptional fractional frequency uncertainty. However, there is still room for improvement: the leading contributions to the uncertainty of most single-ion clocks, such as the 88Sr+ clock operated by the National Research Council of Canada (NRC), are the blackbody radiation shifts and collisional frequency shifts. The uncancelled blackbody radiation shift dominates both the total shift and uncertainty of the existing room temperature strontium ion clocks. To address these sources of inaccuracy, I contributed to developing a strontium ion trap for operation at 4 K. Operating at cryogenic temperatures suppresses the blackbody radiation shift by eight orders of magnitude and collisional shifts by at least two orders of magnitude, enabling substantial improvements to the performance of single-ion clocks. The proposed cryogenic clock is capable of achieving fractional frequency uncertainty below 10−19. This thesis describes the design, construction, and evaluation of the cryogenic ion trap towards realizing a more accurate atomic clock.
We present the current status of the Sr+optical atomic ion clock at the National Research Council of Canada including the study of the quantum projection noise (QPN) limited stability and the progress on the evaluation of the blackbody radiation (BBR) shift uncertainty. The latest QPN limited stability of NRC's Sr+ clock is 3 × 10-15at 1 sec averaging time. The fractional evaluated accuracy of the Sr+ ion clock has reached 1.2 × 10-17and is now dominated by the BBR shift uncertainty, the improved evaluation of which is currently in progress.
Progress of the 40Ca+ ion optical clock based on the 42S1/2 – 3d 2D5/2 electric quadrupole transition is reported. By setting the drive frequency to the “magic” frequency Ω 0, the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10−19 level. By precisely measuring the differential static scalar polarizability Δα 0, the uncertainty due to the blackbody radiation (BBR) shift (coefficient) is reduced to the 10−19 level. With the help of a second-order integrating servo algorithm, the uncertainty due to the servo error is reduced to the 10−18 level. The total fractional uncertainty of the 40Ca+ ion optical clock is then improved to 2.2× 10−17, whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations. The state preparation is introduced together with improvements in the pulse sequence, and furthermore, a better signal to noise ratio (SNR) and less dead time are achieved. The clock stability of a single clock is improved to 4.8 × 10 − 15 / τ ( in seconds ) .
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.
We report on an evaluation of an optical clock that uses the ^{2}S_{1/2}→^{2}D_{5/2} transition of a single ^{88}Sr^{+} ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized sensitivity to thermal radiation. We measure the clock output frequency against an independent ^{171}Yb^{+} ion clock, based on the ^{2}S_{1/2}(F=0)→^{2}F_{7/2}(F=3) electric octupole (E3) transition, and determine the frequency ratio with a total fractional uncertainty of 2.3×10^{-17}. Relying on a previous measurement of the ^{171}Yb^{+} (E3) clock frequency, we find the absolute frequency of the ^{88}Sr^{+} clock transition to be 444 779 044 095 485.277(59) Hz. Our result reduces the uncertainty by a factor of 3 compared with the previously most accurate measurement and may help to resolve so far inconsistent determinations of this value. We also show that for three simultaneously interrogated ^{88}Sr^{+} ions, the increased number causes the expected improvement of the short-term frequency instability of the optical clock without degrading its systematic uncertainty.