Reduction of the Effective Electron Temperature in a Cryogen-free Dilution Refrigerator Via Electronic Filtering and Vibration Dampening

Michael Yannell

Published Jan 1, 2018• 0 citations
OpenAlex

Abstract

Cryogen-free dilution refrigerators (dry fridges) have become an increasingly popular solution to researchers’ cryogenic measurement needs due to their user friendliness and long term use cost savings (4He does not need to be replenished). However, commercially available dry fridges frequently have an effective electron temperatures much warmer than the base temperature of the mixing chamber of the dry fridge. This thesis documents efforts taken to reduce the electron temperature in a dry fridge and the direct probing of the electron temperature via Coulomb blockade thermometry in a 500 nm wide quantum dot.

Related papers

Electron Thermometry

Joost van der Heijden

The performance and accuracy of quantum electronics is substantially degraded when the temperature of the electrons in the devices is too high. The electron temperature can be reduced with appropriate thermal anchoring and by filtering both the low frequency and radio frequency noise. Ultimately, for high performance filters the electron temperature can approach the phonon temperature (as measured by resistive thermometers) in a dilution refrigerator. In this application note, the method for measuring the electron temperature in a typical quantum electronics device using Coulomb blockade thermometry is described. This technique is applied to find the readily achievable electron temperature in the device when using the QFilter provided by QDevil. With our thermometry measurements, using a single GaAs/AlGaAs quantum dot in an optimized experimental setup, we determined an electron temperature of 28 $\pm$ 2 mK for a dilution refrigerator base temperature of 18 mK.

arXiv:2403.16305•Mar 24, 2024•0 citations

Quantum dot thermometry at ultra-low temperature in a dilution refrigerator with a 4He immersion cell

Giorgio Nicolí, Peter Märki, Beat A. Braem +7 more

Experiments performed at a temperature of a few millikelvins require effective thermalization schemes, low-pass filtering of the measurement lines, and low-noise electronics. Here, we report on the modifications to a commercial dilution refrigerator with a base temperature of 3.5 mK that enable us to lower the electron temperature to 6.7 mK measured from the Coulomb peak width of a quantum dot gate-defined in an [Al]GaAs heteostructure. We present the design and implementation of a liquid 4He immersion cell tight against superleaks, implement an innovative wiring technology, and develop optimized transport measurement procedures.

arXiv:1909.10906•Review of Scientific Instruments•Nov 1, 2019•12 citations

Dry Dilution Refrigerator for Experiments on Quantum Effects in the Microwave Regime

Achim Marx, J. Hoess, Kurt Uhlig

At the Walther-Meißner-Institut (WMI), a new cryogen-free 3He/4He dilution refrigerator (DR) has been completed; the cryostat will be employed to cool experiments on superconducting quantum circuits for quantum information technology and quantum simulations. All major components have been made at the WMI. The DR offers lots of space at the various stages of the apparatus for microwave components and cables. E. g., the usable space at the mixing chamber has a height of more than 60 cm and a diameter of 30 cm (mixing chamber mounting plate). To cool cables and cold amplifiers, the DR is equipped with a separate 4He-1K-loop which offers a cooling power of up to 100 mW near 1K. The refrigeration power of the still is 18 mW at 0.9 K; the diameter of its mounting plate is 35 cm. The cryostat rests in an aluminum trestle on air springs to attenuate building vibrations. It is precooled by a Cryomech PT410-RM pulse tube cryocooler (PTC) which is mechanically decoupled from the vacuum can of the cryostat by a bellows assembly. The two stages of the PTC are thermally connected to the DR via copper ropes. There are no nitrogen cooled traps with this DR to purify the gas streams of the 3He and 4He loops; instead, charcoal traps are mounted inside the DR at the first stage of the PTC. The dilution unit has three heat exchangers; its base temperature is 11 mK and its cooling power is 300 μW at 100 mK.

arXiv:1412.3619•Dec 11, 2014•2 citations

Vibration-induced electrical noise in a cryogen-free dilution refrigerator: Characterization, mitigation, and impact on qubit coherence

Rachpon Kalra, Arne Laucht, Juan Pablo Dehollain +5 more

Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5-10 kHz range and its magnitude is found to be strongly temperature dependent. We test the performance of different cables designed to diagnose and tackle the noise, and find triboelectrics to be the dominant mechanism coupling the vibrations to the electrical signal. Flattening a semi-rigid cable or jacketing a flexible cable in order to restrict movement within the cable, successfully reduces the noise level by over an order of magnitude. Furthermore, we characterize the effect of the pulse tube vibrations on an electron spin qubit device in this setup. Coherence measurements are used to map out the spectrum of the noise experienced by the qubit, revealing spectral components matching the spectral signature of the pulse tube.

arXiv:1603.03146•Review of Scientific Instruments•Jul 1, 2016•49 citations

500 microkelvin nanoelectronics

Matthew Sarsby, Nikolai Yurttagül, Attila Geresdi

Abstract Fragile quantum effects such as single electron charging in quantum dots or macroscopic coherent tunneling in superconducting junctions are the basis of modern quantum technologies. These phenomena can only be observed in devices where the characteristic spacing between energy levels exceeds the thermal energy, kBT, demanding effective refrigeration techniques for nanoscale electronic devices. Commercially available dilution refrigerators have enabled typical electron temperatures in the 10 to 100 mK regime, however indirect cooling of nanodevices becomes inefficient due to stray radiofrequency heating and weak thermal coupling of electrons to the device substrate. Here, we report on passing the millikelvin barrier for a nanoelectronic device. Using a combination of on-chip and off-chip nuclear refrigeration, we reach an ultimate electron temperature of Te = 421 ± 35 μK and a hold time exceeding 85 h below 700 μK measured by a self-calibrated Coulomb-blockade thermometer.

arXiv:1903.01388•Nature Communications•Mar 20, 2020•38 citations

A 10 mK hermetic cell for eliminating parasitic heating in cryogen-free dilution refrigerators

D. Schmoranzer, Sumit Kumar, S. Triqueneaux +5 more

Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expected logarithmic temperature dependence of the resonance frequency down to the lowest temperatures, demonstrating that the efficiency of the hermetic shield is significantly better than that of a simpler shield with no visible gaps.

arXiv:1911.03160•Nov 8, 2019•0 citations
Cryogen-free dilution refrigerators (dry fridges) have become an increasingly popular solution to researchers’ cryogenic measurement needs due to their user friendliness and long term use cost savings (4He does not need to be replenished). However, commercially available dry fridges frequently have an effective electron temperatures much warmer than the base temperature of the mixing chamber of the dry fridge. This thesis documents efforts taken to reduce the electron temperature in a dry fridge and the direct probing of the electron temperature via Coulomb blockade thermometry in a 500 nm wide quantum dot.
The performance and accuracy of quantum electronics is substantially degraded when the temperature of the electrons in the devices is too high. The electron temperature can be reduced with appropriate thermal anchoring and by filtering both the low frequency and radio frequency noise. Ultimately, for high performance filters the electron temperature can approach the phonon temperature (as measured by resistive thermometers) in a dilution refrigerator. In this application note, the method for measuring the electron temperature in a typical quantum electronics device using Coulomb blockade thermometry is described. This technique is applied to find the readily achievable electron temperature in the device when using the QFilter provided by QDevil. With our thermometry measurements, using a single GaAs/AlGaAs quantum dot in an optimized experimental setup, we determined an electron temperature of 28 ±\pm± 2 mK for a dilution refrigerator base temperature of 18 mK.
Experiments performed at a temperature of a few millikelvins require effective thermalization schemes, low-pass filtering of the measurement lines, and low-noise electronics. Here, we report on the modifications to a commercial dilution refrigerator with a base temperature of 3.5 mK that enable us to lower the electron temperature to 6.7 mK measured from the Coulomb peak width of a quantum dot gate-defined in an [Al]GaAs heteostructure. We present the design and implementation of a liquid 4He immersion cell tight against superleaks, implement an innovative wiring technology, and develop optimized transport measurement procedures.
At the Walther-Meißner-Institut (WMI), a new cryogen-free 3He/4He dilution refrigerator (DR) has been completed; the cryostat will be employed to cool experiments on superconducting quantum circuits for quantum information technology and quantum simulations. All major components have been made at the WMI. The DR offers lots of space at the various stages of the apparatus for microwave components and cables. E. g., the usable space at the mixing chamber has a height of more than 60 cm and a diameter of 30 cm (mixing chamber mounting plate). To cool cables and cold amplifiers, the DR is equipped with a separate 4He-1K-loop which offers a cooling power of up to 100 mW near 1K. The refrigeration power of the still is 18 mW at 0.9 K; the diameter of its mounting plate is 35 cm. The cryostat rests in an aluminum trestle on air springs to attenuate building vibrations. It is precooled by a Cryomech PT410-RM pulse tube cryocooler (PTC) which is mechanically decoupled from the vacuum can of the cryostat by a bellows assembly. The two stages of the PTC are thermally connected to the DR via copper ropes. There are no nitrogen cooled traps with this DR to purify the gas streams of the 3He and 4He loops; instead, charcoal traps are mounted inside the DR at the first stage of the PTC. The dilution unit has three heat exchangers; its base temperature is 11 mK and its cooling power is 300 μW at 100 mK.
Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5-10 kHz range and its magnitude is found to be strongly temperature dependent. We test the performance of different cables designed to diagnose and tackle the noise, and find triboelectrics to be the dominant mechanism coupling the vibrations to the electrical signal. Flattening a semi-rigid cable or jacketing a flexible cable in order to restrict movement within the cable, successfully reduces the noise level by over an order of magnitude. Furthermore, we characterize the effect of the pulse tube vibrations on an electron spin qubit device in this setup. Coherence measurements are used to map out the spectrum of the noise experienced by the qubit, revealing spectral components matching the spectral signature of the pulse tube.
Abstract Fragile quantum effects such as single electron charging in quantum dots or macroscopic coherent tunneling in superconducting junctions are the basis of modern quantum technologies. These phenomena can only be observed in devices where the characteristic spacing between energy levels exceeds the thermal energy, kBT, demanding effective refrigeration techniques for nanoscale electronic devices. Commercially available dilution refrigerators have enabled typical electron temperatures in the 10 to 100 mK regime, however indirect cooling of nanodevices becomes inefficient due to stray radiofrequency heating and weak thermal coupling of electrons to the device substrate. Here, we report on passing the millikelvin barrier for a nanoelectronic device. Using a combination of on-chip and off-chip nuclear refrigeration, we reach an ultimate electron temperature of Te = 421 ± 35 μK and a hold time exceeding 85 h below 700 μK measured by a self-calibrated Coulomb-blockade thermometer.
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expected logarithmic temperature dependence of the resonance frequency down to the lowest temperatures, demonstrating that the efficiency of the hermetic shield is significantly better than that of a simpler shield with no visible gaps.