arXiv:2403.16305

Electron Thermometry

Joost van der Heijden

Published Mar 24, 2024• 0 citations
arXivHTMLPDF

Abstract

The performance and accuracy of quantum electronics is substantially degraded when the temperature of the electrons in the devices is too high. The electron temperature can be reduced with appropriate thermal anchoring and by filtering both the low frequency and radio frequency noise. Ultimately, for high performance filters the electron temperature can approach the phonon temperature (as measured by resistive thermometers) in a dilution refrigerator. In this application note, the method for measuring the electron temperature in a typical quantum electronics device using Coulomb blockade thermometry is described. This technique is applied to find the readily achievable electron temperature in the device when using the QFilter provided by QDevil. With our thermometry measurements, using a single GaAs/AlGaAs quantum dot in an optimized experimental setup, we determined an electron temperature of 28 $\pm$ 2 mK for a dilution refrigerator base temperature of 18 mK.

DOI
10.48550/arxiv.2403.16305

Related papers

Low-temperature benchmarking of qubit control wires by primary electron thermometry

Elias Roos Hansen, Ferdinand Kuemmeth, Joost van der Heijden

Low-frequency qubit control wires require non-trivial thermal anchoring and low-pass filtering. The resulting electron temperature serves as a quality benchmark for these signal lines. In this technical note, we make use of a primary electron thermometry technique, using a Coulomb blockade thermometer, to establish the electron temperature in the millikelvin regime. The experimental four-probe measurement setup, the data analysis, and the measurement limitations are discussed in detail. We verify the results by also using another electron thermometry technique, based on a superconductor-insulator-normal metal junction. Our comparison of signal lines with QDevil's QFilter to unfiltered signal lines demonstrates that the filter significantly reduces both the rms noise and electron temperature, which is measured to be 22 $\pm$ 1 mK.

arXiv:2403.17720•Jan 1, 2024•0 citations

Quantum dot thermometry at ultra-low temperature in a dilution refrigerator with a 4He immersion cell

Giorgio Nicolí, Peter Märki, Beat A. Braem +7 more

Experiments performed at a temperature of a few millikelvins require effective thermalization schemes, low-pass filtering of the measurement lines, and low-noise electronics. Here, we report on the modifications to a commercial dilution refrigerator with a base temperature of 3.5 mK that enable us to lower the electron temperature to 6.7 mK measured from the Coulomb peak width of a quantum dot gate-defined in an [Al]GaAs heteostructure. We present the design and implementation of a liquid 4He immersion cell tight against superleaks, implement an innovative wiring technology, and develop optimized transport measurement procedures.

arXiv:1909.10906•Review of Scientific Instruments•Nov 1, 2019•12 citations

Reduction of the Effective Electron Temperature in a Cryogen-free Dilution Refrigerator Via Electronic Filtering and Vibration Dampening

Michael Yannell

Cryogen-free dilution refrigerators (dry fridges) have become an increasingly popular solution to researchers’ cryogenic measurement needs due to their user friendliness and long term use cost savings (4He does not need to be replenished). However, commercially available dry fridges frequently have an effective electron temperatures much warmer than the base temperature of the mixing chamber of the dry fridge. This thesis documents efforts taken to reduce the electron temperature in a dry fridge and the direct probing of the electron temperature via Coulomb blockade thermometry in a 500 nm wide quantum dot.

•Jan 1, 2018•0 citations

Nongalvanic Calibration and Operation of a Quantum Dot Thermometer

Joshua Chawner, Sylvain Barraud, M. Fernando González-Zalba +4 more

A cryogenic quantum dot thermometer is calibrated and operated using only a single non-galvanic gate connection. The thermometer is probed with radio-frequency reflectometry and calibrated by fitting a physical model to the phase of the reflected radio-frequency signal taken at temperatures across a small range. Thermometry of the source and drain reservoirs of the dot is then performed by fitting the calibrated physical model to new phase data. The thermometer can operate at the transition between thermally broadened and lifetime broadened regimes, and outside the temperatures used in calibration. Electron thermometry was performed at temperatures between $3.0\,\mathrm{K}$ and $1.0\,\mathrm{K}$, in both a $1\,\mathrm{K}$ cryostat and a dilution refrigerator. The experimental setup allows fast electron temperature readout with a sensitivity of $4.0\pm0.3 \, \mathrm{mK}/\sqrt{\mathrm{Hz}}$, at Kelvin temperatures. The non-galvanic calibration process gives a readout of physical parameters, such as the quantum dot lever arm. The demodulator used for reflectometry readout is readily available and very affordable.

arXiv:2012.01209•Physical Review Applied•Mar 16, 2021•15 citations

500 microkelvin nanoelectronics

Matthew Sarsby, Nikolai Yurttagül, Attila Geresdi

Abstract Fragile quantum effects such as single electron charging in quantum dots or macroscopic coherent tunneling in superconducting junctions are the basis of modern quantum technologies. These phenomena can only be observed in devices where the characteristic spacing between energy levels exceeds the thermal energy, kBT, demanding effective refrigeration techniques for nanoscale electronic devices. Commercially available dilution refrigerators have enabled typical electron temperatures in the 10 to 100 mK regime, however indirect cooling of nanodevices becomes inefficient due to stray radiofrequency heating and weak thermal coupling of electrons to the device substrate. Here, we report on passing the millikelvin barrier for a nanoelectronic device. Using a combination of on-chip and off-chip nuclear refrigeration, we reach an ultimate electron temperature of Te = 421 ± 35 μK and a hold time exceeding 85 h below 700 μK measured by a self-calibrated Coulomb-blockade thermometer.

arXiv:1903.01388•Nature Communications•Mar 20, 2020•38 citations

Noise measurement system at electron temperature down to 20 mK with combinations of the low pass filters

Masayuki Hashisaka, Yoshiaki Yamauchi, Kensaku Chida +3 more

We developed a quantum noise measurement system in a dilution refrigerator by using three kinds of cryogenic low pass filters. One of them is a commercial low pass filter inserted into the noise measurement lines instead of the conventional powder filter, which assures well-defined circuit parameters necessary for the noise measurement at a finite frequency. We checked that this filter gives sufficiently large attenuation up to 20 GHz at room temperature, 77 and 4.2 K. The electron temperature of the mesoscopic device placed in the present system was confirmed to be down to around 20 mK by measuring the thermal noise of the device.

Review of Scientific Instruments•Sep 1, 2009•21 citations
The performance and accuracy of quantum electronics is substantially degraded when the temperature of the electrons in the devices is too high. The electron temperature can be reduced with appropriate thermal anchoring and by filtering both the low frequency and radio frequency noise. Ultimately, for high performance filters the electron temperature can approach the phonon temperature (as measured by resistive thermometers) in a dilution refrigerator. In this application note, the method for measuring the electron temperature in a typical quantum electronics device using Coulomb blockade thermometry is described. This technique is applied to find the readily achievable electron temperature in the device when using the QFilter provided by QDevil. With our thermometry measurements, using a single GaAs/AlGaAs quantum dot in an optimized experimental setup, we determined an electron temperature of 28 ±\pm± 2 mK for a dilution refrigerator base temperature of 18 mK.
Low-frequency qubit control wires require non-trivial thermal anchoring and low-pass filtering. The resulting electron temperature serves as a quality benchmark for these signal lines. In this technical note, we make use of a primary electron thermometry technique, using a Coulomb blockade thermometer, to establish the electron temperature in the millikelvin regime. The experimental four-probe measurement setup, the data analysis, and the measurement limitations are discussed in detail. We verify the results by also using another electron thermometry technique, based on a superconductor-insulator-normal metal junction. Our comparison of signal lines with QDevil's QFilter to unfiltered signal lines demonstrates that the filter significantly reduces both the rms noise and electron temperature, which is measured to be 22 ±\pm± 1 mK.
Experiments performed at a temperature of a few millikelvins require effective thermalization schemes, low-pass filtering of the measurement lines, and low-noise electronics. Here, we report on the modifications to a commercial dilution refrigerator with a base temperature of 3.5 mK that enable us to lower the electron temperature to 6.7 mK measured from the Coulomb peak width of a quantum dot gate-defined in an [Al]GaAs heteostructure. We present the design and implementation of a liquid 4He immersion cell tight against superleaks, implement an innovative wiring technology, and develop optimized transport measurement procedures.
Cryogen-free dilution refrigerators (dry fridges) have become an increasingly popular solution to researchers’ cryogenic measurement needs due to their user friendliness and long term use cost savings (4He does not need to be replenished). However, commercially available dry fridges frequently have an effective electron temperatures much warmer than the base temperature of the mixing chamber of the dry fridge. This thesis documents efforts taken to reduce the electron temperature in a dry fridge and the direct probing of the electron temperature via Coulomb blockade thermometry in a 500 nm wide quantum dot.
A cryogenic quantum dot thermometer is calibrated and operated using only a single non-galvanic gate connection. The thermometer is probed with radio-frequency reflectometry and calibrated by fitting a physical model to the phase of the reflected radio-frequency signal taken at temperatures across a small range. Thermometry of the source and drain reservoirs of the dot is then performed by fitting the calibrated physical model to new phase data. The thermometer can operate at the transition between thermally broadened and lifetime broadened regimes, and outside the temperatures used in calibration. Electron thermometry was performed at temperatures between 3.0 K3.0\,\mathrm{K}3.0K and 1.0 K1.0\,\mathrm{K}1.0K, in both a 1 K1\,\mathrm{K}1K cryostat and a dilution refrigerator. The experimental setup allows fast electron temperature readout with a sensitivity of 4.0±0.3 mK/Hz4.0\pm0.3 \, \mathrm{mK}/\sqrt{\mathrm{Hz}}4.0±0.3mK/Hz​, at Kelvin temperatures. The non-galvanic calibration process gives a readout of physical parameters, such as the quantum dot lever arm. The demodulator used for reflectometry readout is readily available and very affordable.
Abstract Fragile quantum effects such as single electron charging in quantum dots or macroscopic coherent tunneling in superconducting junctions are the basis of modern quantum technologies. These phenomena can only be observed in devices where the characteristic spacing between energy levels exceeds the thermal energy, kBT, demanding effective refrigeration techniques for nanoscale electronic devices. Commercially available dilution refrigerators have enabled typical electron temperatures in the 10 to 100 mK regime, however indirect cooling of nanodevices becomes inefficient due to stray radiofrequency heating and weak thermal coupling of electrons to the device substrate. Here, we report on passing the millikelvin barrier for a nanoelectronic device. Using a combination of on-chip and off-chip nuclear refrigeration, we reach an ultimate electron temperature of Te = 421 ± 35 μK and a hold time exceeding 85 h below 700 μK measured by a self-calibrated Coulomb-blockade thermometer.
We developed a quantum noise measurement system in a dilution refrigerator by using three kinds of cryogenic low pass filters. One of them is a commercial low pass filter inserted into the noise measurement lines instead of the conventional powder filter, which assures well-defined circuit parameters necessary for the noise measurement at a finite frequency. We checked that this filter gives sufficiently large attenuation up to 20 GHz at room temperature, 77 and 4.2 K. The electron temperature of the mesoscopic device placed in the present system was confirmed to be down to around 20 mK by measuring the thermal noise of the device.