Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Optimizing ion trap design with improved potential field and molecular dynamics simulation

Liangyu Ding, Xiang Zhang, Qiuxin Zhang, Danna Shen, Xiran Sun, Wei Zhang

Published May 31, 2018• 0 citations
OpenAlex

Related papers

Effect of ion-trap parameters on energy distributions of ultra-cold atom–ion mixtures

Meirav Pinkas, Ziv Meir, Tomáš Šikorský +3 more

Abstract Experiments in which ultra-cold neutral atoms and charged ions are overlapped, constitute a new field in atomic and molecular physics, with applications ranging from studying out-of-equilibrium dynamics to simulating quantum many-body systems. The holy grail of ion-neutral systems is reaching the quantum low-energy scattering regime, known as the s-wave scattering. However, in most atom–ion systems, there is a fundamental limit that prohibits reaching this regime. This limit arises from the time-dependent trapping potential of the ion, the Paul trap, which sets a lower collision energy limit which is higher than the s-wave energy. In this work, we studied both theoretically and experimentally, the way the Paul trap parameters affect the energy distribution of an ion that is immersed in a bath of ultra-cold atoms. Heating rates and energy distributions of the ion are calculated for various trap parameters by a molecular dynamics (MD) simulation that takes into account the attractive atom–ion potential. The deviation of the energy distribution from a thermal one is discussed. Using the MD simulation, the heating dynamics for different atom–ion combinations is also investigated. In addition, we performed measurements of the heating rates of a ground-state cooled 88Sr+ ion that is immersed in an ultra-cold cloud of 87Rb atoms, over a wide range of trap parameters, and compare our results to the MD simulation. Both the simulation and the experiment reveal no significant change in the heating for different parameters of the trap. However, in the experiment a slightly higher global heating is observed, relative to the simulation.

arXiv:1907.12815•New Journal of Physics•Jan 1, 2020•20 citations

Molecular Dynamics Inside Ion Traps

Susan L. Fischer, Wolfgang Christian, Denis Donnelly

Computers in Physics•Mar 1, 1996•2 citations

Design, Development and Operation of Novel Ion Trap Geometries

José Rafael Castrejón-Pita

•Apr 5, 2009•1 citation

Optimization of endcap trap for single-ion manipulation

Yuan Qian, Chang-Da-Ren Fang, Yao Huang +2 more

Potential distribution is an important characteristic for evaluating the performance of an ion trap. Here, we analyze and optimize the potential distribution of an endcap ion trap for single-ion trapping. We obtain an optimal endcap radius of 225 μm–250 μm, endcap-shield gap of ∼ 250 μm, and inter-endcap distance of 540 μm–590 μm. The simulation method for analysis can also be applied to other ion traps, which is useful for improving the design and assembly of ion traps.

Chinese Physics B•Jun 1, 2018•2 citations

Design, Development and Operation of Novel Ion Trap Geometries

Castrejon-Pita

•Apr 30, 2009•0 citations

Design optimization and precision requirements of an endcap ion trap for single-ion optical clock applications

Chaowei Wang, Shaoyang Dai, Yani Zuo +1 more

Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.

AIP Advances•May 1, 2025•2 citations
Abstract Experiments in which ultra-cold neutral atoms and charged ions are overlapped, constitute a new field in atomic and molecular physics, with applications ranging from studying out-of-equilibrium dynamics to simulating quantum many-body systems. The holy grail of ion-neutral systems is reaching the quantum low-energy scattering regime, known as the s-wave scattering. However, in most atom–ion systems, there is a fundamental limit that prohibits reaching this regime. This limit arises from the time-dependent trapping potential of the ion, the Paul trap, which sets a lower collision energy limit which is higher than the s-wave energy. In this work, we studied both theoretically and experimentally, the way the Paul trap parameters affect the energy distribution of an ion that is immersed in a bath of ultra-cold atoms. Heating rates and energy distributions of the ion are calculated for various trap parameters by a molecular dynamics (MD) simulation that takes into account the attractive atom–ion potential. The deviation of the energy distribution from a thermal one is discussed. Using the MD simulation, the heating dynamics for different atom–ion combinations is also investigated. In addition, we performed measurements of the heating rates of a ground-state cooled 88Sr+ ion that is immersed in an ultra-cold cloud of 87Rb atoms, over a wide range of trap parameters, and compare our results to the MD simulation. Both the simulation and the experiment reveal no significant change in the heating for different parameters of the trap. However, in the experiment a slightly higher global heating is observed, relative to the simulation.
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.