Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Design, Development and Operation of Novel Ion Trap Geometries

José Rafael Castrejón-Pita

Published Apr 5, 2009• 1 citation
OpenAlex

Related papers

Design, development and operation of novel ion trap geometries : novel desings for ion traps

José Rafael Castrejón-Pita

VDM Verlag Dr. Müller eBooks•Jan 1, 2009•0 citations

Design, Development and Operation of Novel Ion Trap Geometries

Castrejon-Pita

•Apr 30, 2009•0 citations

Development and Characterization of a 171Yb+ Miniature Ion Trap Frequency Standard

Heather L. Partner

This dissertation reports on the development of a low-power, high-stability miniature atomic frequency standard based on 171Yb+ ions. The ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed, getter-pumped vacuum package, and interrogated on the 12.6 GHz hyperfine transition. We hope to achieve a long-term fractional frequency stability of 10^-14 with a miniature clock that consumes only 50 mW of power and occupies a volume of 5 cm^3. I discuss our progress over several years of work on this project. We began by building a conventional tabletop clock to use as a test bed while developing several designs of miniature ion-trap vacuum packages, while also developing techniques for various aspects of the clock operation, including ion loading, laser and magnetic field stabilization, and a low power ion trap drive. The ion traps were modeled using boundary element software to assist with the design and parameter optimization of new trap geometries. We expect a novel trap geometry that uses a material new to ion traps to lead to an exceptionally small ion trap vacuum package in the next phase of the project. To achieve the long-term stability required, we have also considered the sensitivity of the clock frequency to magnetic fields. A study of the motion of the individual ions in a room-temperature cloud in the trap was performed with the purpose of understanding the effect of both spatially varying and constant magnetic fields on the clock resonance and therefore the operation of the clock. These effects were studied experimentally and theoretically for several traps. In summary, this dissertation is a contribution to the design, development, and testing of a 171Yb+ ion cloud frequency standard and related techniques, including analyses of trap geometries and parameters, modeling of the ion motion, and the practical operation of the clock.

arXiv:1208.5622•Aug 28, 2012•2 citations

Fabrication and Applications of Ion Traps.

Daniel Stick

•Jul 1, 2007•0 citations

Advanced Technologies for Ion Trap Systems

Jonathan David Sterk

•Sep 1, 2023•0 citations

Yb+ ion trapping and optimum planar trap geometries for scalable quantum technology

Altaf Hussain Nizamani

Trapped ions in linear Paul traps are largely isolated from interaction with the environment. This property of trapped ions make them a primary choice for quantum technology. \nOver the last decade, trapped atomic ions in linear radio frequency Paul traps have shown to be an important tool to implement quantum algorithms. The scalability of linear ion \ntraps is required to handle large numbers of qubits, in order to implement useful quantum computation. Advance micro-fabrication technology allows the realisation of scalable ion traps. Further developments of micro-trap designs, for the purpose of scalable quantum technology, requires inter-disciplinary investigations of ion traps. Micro-scale ion trap designs typically require a versatile experimental setup. The first part of this thesis describes such an experimental setup including a chip bracket that can host macroscopic ion traps as well as advanced symmetric and asymmetric ion trap chips with up to 90 control electrodes. The system provides versatile optical access for both type of traps and the vacuum chamber is designed in a way so the ion traps can be replaced within a short amount of time. To test the working of the setup, a macroscopic ion trap with an ion-electrode distance of 310±10 μm is used to trap ytterbium ions (Yb+). The trap is characterised by measuring the heating rate, (n•), and spectral noise density SE(ω). A \nphotoionisation technique is used to ionise the different isotopes of Yb in our trap. Isotope selective photoionisation requires exact measurements of 1So↔1P1 transition for the different Yb isotopes. A technique to measure these resonant frequencies is described. \nThis technique works by observing and aligning fluorescence spots and by using this technique, the 1So↔1P1 transition frequencies for stable isotopes of Yb were measured with an accuracy of 60 MHz. These new measured transition frequencies for stable Yb isotopes differ from previously published work by 660 MHz. Furthermore, this technique can also be used to obtain the transition frequencies at different laser-atomic beam angles, typical for non-perpendicular laser-atomic beam angles. The second part of this thesis discusses the optimisation of surface trap geometries as they are being used to implement scalable ion trap designs which consist of a large number of trapping zones. The trap depth in surface traps is low compared to symmetric traps of similar dimensions. How to optimise the trap geometry to achieve maximum trap depth for a given ion height above the trap electrodes, is discussed. Fast and adiabatic ion shuttling operations in one dimension as well as ion separation and recombination processes are important for many quantum information implementations. The maximum speed of separation of trapped ions for adiabatic shuttling operations depends on the secular frequencies, the trapped ion experiences in the process. It will be shown how such ion trap structures have to be designed for fast ion separation process and linear shuttling. Numerical results of adiabatic shuttling operations for trapped ions in such trap structures are also presented.

•Aug 6, 2011•1 citation
This dissertation reports on the development of a low-power, high-stability miniature atomic frequency standard based on 171Yb+ ions. The ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed, getter-pumped vacuum package, and interrogated on the 12.6 GHz hyperfine transition. We hope to achieve a long-term fractional frequency stability of 10^-14 with a miniature clock that consumes only 50 mW of power and occupies a volume of 5 cm^3. I discuss our progress over several years of work on this project. We began by building a conventional tabletop clock to use as a test bed while developing several designs of miniature ion-trap vacuum packages, while also developing techniques for various aspects of the clock operation, including ion loading, laser and magnetic field stabilization, and a low power ion trap drive. The ion traps were modeled using boundary element software to assist with the design and parameter optimization of new trap geometries. We expect a novel trap geometry that uses a material new to ion traps to lead to an exceptionally small ion trap vacuum package in the next phase of the project. To achieve the long-term stability required, we have also considered the sensitivity of the clock frequency to magnetic fields. A study of the motion of the individual ions in a room-temperature cloud in the trap was performed with the purpose of understanding the effect of both spatially varying and constant magnetic fields on the clock resonance and therefore the operation of the clock. These effects were studied experimentally and theoretically for several traps. In summary, this dissertation is a contribution to the design, development, and testing of a 171Yb+ ion cloud frequency standard and related techniques, including analyses of trap geometries and parameters, modeling of the ion motion, and the practical operation of the clock.
Trapped ions in linear Paul traps are largely isolated from interaction with the environment. This property of trapped ions make them a primary choice for quantum technology. \nOver the last decade, trapped atomic ions in linear radio frequency Paul traps have shown to be an important tool to implement quantum algorithms. The scalability of linear ion \ntraps is required to handle large numbers of qubits, in order to implement useful quantum computation. Advance micro-fabrication technology allows the realisation of scalable ion traps. Further developments of micro-trap designs, for the purpose of scalable quantum technology, requires inter-disciplinary investigations of ion traps. Micro-scale ion trap designs typically require a versatile experimental setup. The first part of this thesis describes such an experimental setup including a chip bracket that can host macroscopic ion traps as well as advanced symmetric and asymmetric ion trap chips with up to 90 control electrodes. The system provides versatile optical access for both type of traps and the vacuum chamber is designed in a way so the ion traps can be replaced within a short amount of time. To test the working of the setup, a macroscopic ion trap with an ion-electrode distance of 310±10 μm is used to trap ytterbium ions (Yb+). The trap is characterised by measuring the heating rate, (n•), and spectral noise density SE(ω). A \nphotoionisation technique is used to ionise the different isotopes of Yb in our trap. Isotope selective photoionisation requires exact measurements of 1So↔1P1 transition for the different Yb isotopes. A technique to measure these resonant frequencies is described. \nThis technique works by observing and aligning fluorescence spots and by using this technique, the 1So↔1P1 transition frequencies for stable isotopes of Yb were measured with an accuracy of 60 MHz. These new measured transition frequencies for stable Yb isotopes differ from previously published work by 660 MHz. Furthermore, this technique can also be used to obtain the transition frequencies at different laser-atomic beam angles, typical for non-perpendicular laser-atomic beam angles. The second part of this thesis discusses the optimisation of surface trap geometries as they are being used to implement scalable ion trap designs which consist of a large number of trapping zones. The trap depth in surface traps is low compared to symmetric traps of similar dimensions. How to optimise the trap geometry to achieve maximum trap depth for a given ion height above the trap electrodes, is discussed. Fast and adiabatic ion shuttling operations in one dimension as well as ion separation and recombination processes are important for many quantum information implementations. The maximum speed of separation of trapped ions for adiabatic shuttling operations depends on the secular frequencies, the trapped ion experiences in the process. It will be shown how such ion trap structures have to be designed for fast ion separation process and linear shuttling. Numerical results of adiabatic shuttling operations for trapped ions in such trap structures are also presented.