Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

On the interplay between kinetic inductance fraction and Kerr non-linearities in superconducting resonators for millimeter wave detection

Francesco Valenti, Fábio Henriques, Nataliya Maleeva, Uwe von Lüpke, Lukas Grünhaupt, Patrick Winkel, Sebastian T. Skacel, Alexander Bilmes, Alexey Vladimirovich Ustinov, F. Lévy-Bertrand, Allessandro Monfardini, Ioan M. Pop

Published Jan 1, 2018• 0 citations
OpenAlex

Related papers

Accessing Nonlinearity in Superconducting Millimeter Wave Coplanar Resonators

Alexander Anferov, Aziza Suleymanzade, Jonathan Simon +1 more

Bulletin of the American Physical Society•Mar 7, 2019•0 citations

Large parametric amplification in kinetic inductance dominant resonators based on 3 nm-thick epitaxial superconductors

Wei-Chen Chien, Yu‐Han Chang, Xinlu Cheng +4 more

Abstract Ultra-thin superconducting aluminum films of 3-nm grown on sapphire by molecule-beam epitaxy show excellent superconductivity and large kinetic inductance. This results in a record high Kerr non-linearity of 33 kHz and 3.62 MHz per photon in notch-type and transmission-type resonators, respectively. 4-wave mixing leverages this non-linearity to achieve 12 dB parametric amplification in transmission type resonator, making the ultra-thin film ideal for photon detection and amplification applications.

Materials for Quantum Technology•May 19, 2023•7 citations

Analyzing and modeling of an ultra-compact superconducting resonator for kinetic inductance detectors applications

Morteza Heidari, Seyed Mohammad Hassan Javadzadeh

Physica C Superconductivity•Nov 11, 2021•0 citations

Ultrastable millimeter-wave kinetic inductance detectors

Michael R. Vissers, Jason E. Austermann, M. Malnou +6 more

We demonstrate microwave kinetic inductance detectors (MKIDs) whose sensitivity is limited by photon noise at signal frequencies as low as 50 mHz. The subhertz part of the detection spectrum is important for contemporary millimeter-wave science, yet photon noise below 1 Hz in MKIDs has not previously been unambiguously demonstrated. These feedhorn-coupled detectors are sensitive over a 40% fractional bandwidth centered on λ = 2 mm, are dual-polarization-sensitive, and consist of lumped-element superconducting resonators fabricated from a hybrid of stoichiometric TiN and Al films together with an amorphous-Si passivation layer. When observing a 7 K, 3.8 pW thermal load and employing no signal modulation scheme, the measured noise spectrum is white down to 50 mHz and has an amplitude consistent with photon noise. These results have implications for the development of large-format, polarization-sensitive, millimeter-wave imagers.

Applied Physics Letters•Jan 21, 2020•16 citations

Analysis and Performance of Lumped-Element Kinetic Inductance Detectors for W-Band

B. Aja, Marina C. de Ory, Luisa de la Fuente +5 more

Lumped-element superconducting resonators are a promising technology for their use in millimeter-wave observations and quantum computing applications that require large arrays of extremely sensitive detectors. Among them, lumped-element kinetic inductance detectors (LEKIDs) have shown good performance in the submillimeter band in several earth-based telescopes. In this work, LEKIDs for their use as millimeter-wave receivers of astronomical applications are presented. LEKID arrays using a thin bilayer of superconducting titanium/aluminum (Ti/Al), deposited on the silicon substrate, have been designed and fabricated. The design of a dual-polarization LEKID with the goal of detection at the W-band for two orthogonal polarizations is described and a fabricated array has demonstrated absorption at ambient temperature. Also, an approximate design methodology of the coupling parameter for LEKIDs' readout, essential for dynamic range optimization of the detector under millimeter-wave radiation, is proposed. In addition, the resonance characteristics and coupling factor of the fabricated superconducting resonators using high-quality internal factor Qiunder cryogenic temperatures have been analyzed. The design guidelines in this work are applicable to other LEKID arrays, and the presented superconducting Ti/Al thin-film LEKIDs can be used in future receiver arrays in the millimeter bands.

IEEE Transactions on Microwave Theory and Techniques•Dec 3, 2020•10 citations

Development of high-Q superconducting resonators for use as kinetic inductance detectors

J. J. A. Baselmans, S. J. C. Yates, Piet A. J. de Korte +5 more

Advances in Space Research•Jan 1, 2007•19 citations
Abstract Ultra-thin superconducting aluminum films of 3-nm grown on sapphire by molecule-beam epitaxy show excellent superconductivity and large kinetic inductance. This results in a record high Kerr non-linearity of 33 kHz and 3.62 MHz per photon in notch-type and transmission-type resonators, respectively. 4-wave mixing leverages this non-linearity to achieve 12 dB parametric amplification in transmission type resonator, making the ultra-thin film ideal for photon detection and amplification applications.
We demonstrate microwave kinetic inductance detectors (MKIDs) whose sensitivity is limited by photon noise at signal frequencies as low as 50 mHz. The subhertz part of the detection spectrum is important for contemporary millimeter-wave science, yet photon noise below 1 Hz in MKIDs has not previously been unambiguously demonstrated. These feedhorn-coupled detectors are sensitive over a 40% fractional bandwidth centered on λ = 2 mm, are dual-polarization-sensitive, and consist of lumped-element superconducting resonators fabricated from a hybrid of stoichiometric TiN and Al films together with an amorphous-Si passivation layer. When observing a 7 K, 3.8 pW thermal load and employing no signal modulation scheme, the measured noise spectrum is white down to 50 mHz and has an amplitude consistent with photon noise. These results have implications for the development of large-format, polarization-sensitive, millimeter-wave imagers.
Lumped-element superconducting resonators are a promising technology for their use in millimeter-wave observations and quantum computing applications that require large arrays of extremely sensitive detectors. Among them, lumped-element kinetic inductance detectors (LEKIDs) have shown good performance in the submillimeter band in several earth-based telescopes. In this work, LEKIDs for their use as millimeter-wave receivers of astronomical applications are presented. LEKID arrays using a thin bilayer of superconducting titanium/aluminum (Ti/Al), deposited on the silicon substrate, have been designed and fabricated. The design of a dual-polarization LEKID with the goal of detection at the W-band for two orthogonal polarizations is described and a fabricated array has demonstrated absorption at ambient temperature. Also, an approximate design methodology of the coupling parameter for LEKIDs' readout, essential for dynamic range optimization of the detector under millimeter-wave radiation, is proposed. In addition, the resonance characteristics and coupling factor of the fabricated superconducting resonators using high-quality internal factor Qiunder cryogenic temperatures have been analyzed. The design guidelines in this work are applicable to other LEKID arrays, and the presented superconducting Ti/Al thin-film LEKIDs can be used in future receiver arrays in the millimeter bands.