Chinese Physics B

Comparison of the sensitivities for atom interferometers in two different operation methods

Xiao‐Chun Duan, Dekai Mao, Xiao-Bing Deng, Min-Kang Zhou, Cheng-Gang Shao, Zhu Zhu, Zhong-Kun Hu

Published Jan 1, 2018• 3 citations
Publisher

Abstract

We investigated the sensitivities of atom interferometers in the usual fringe-scanning method (FSM) versus the fringe-locking method (FLM). The theoretical analysis shows that for typical noises in atom interferometers, the FSM will degrade the sensitivity while the FLM does not. The sensitivity-improvement factor of the FLM over the FSM depends on the type of noises, which is validated by numerical simulations. The detailed quantitative analysis on this fundamental issue is presented, and our analysis is readily extendable to other kinds of noises as well as other fringe shapes in addition to a cosine one.

DOI
10.1088/1674-1056/27/1/013701

Related papers

Fringe-locking method for the weak equivalence principle test by simultaneous dual-species atom interferometers

Xiao‐Chun Duan, Xiao-Bing Deng, Dekai Mao +3 more

We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.

arXiv:1603.01321•Mar 4, 2016•0 citations

Analyzing the sensitivity of an atom interferometer with a phase-modulation readout scheme

Takuya Kawasaki, Sotatsu Otabe, Tomoya Sato +3 more

The sensitivity of an interferometer depends on its readout scheme. However, little attention has been paid to the readout schemes of atom interferometers from the viewpoint of their sensitivity. The difference in sensitivity between readout schemes or their optimization has not been considered in the literature. Herein we analytically calculate the sensitivities of an atom interferometer with typical readout schemes by applying the two-photon formalism, which was developed for optical interferometers to deal with quantum noise. Our calculations reveal that by using sinusoidal phase modulation, the sensitivity can surpass that obtained by the conventional phase sweeping scheme. The superiority of this phase modulation scheme for both cold and thermal atomic beams is demonstrated. In addition, we show that the phase modulation scheme is advantageous for atom-flux fluctuation and resists atom-flux drift. This study performs a general analysis of the sensitivity of atom interferometers and identifies an advantageous readout scheme.

arXiv:2406.03911•Physical Review A•Jan 2, 2025•3 citations

Improvement of atom interferometer by rejecting typical noise sources

Wei Hong Gao, Lin Zhang, Qian Li +1 more

In this paper, we review the progress of atom interferometer sensors. Previous research institutions focused on how to improve the atom interferometers as an independent sensor. We have shown the atom interferometry and the sensitivity function which is helpful on noise evaluation, and demonstrated some rejection approaches of laser noise, vibration noise, and detection noise after comparison.

IEEE/ION Position Location and Navigation Symposium•Apr 1, 2016•0 citations

Vibration induced phase noise in Mach-Zehnder atom interferometers

Alain Miffre, Marion Jacquey, M Büchner +2 more

The high inertial sensitivity of atom interferometers has been used to build accelerometers and gyrometers but this sensitivity makes these interferometers very sensitive to the laboratory seismic noise. This seismic noise induces a phase noise which is large enough to reduce the fringe visibility in many cases. We develop here a model calculation of this phase noise in the case of Mach-Zehnder atom interferometers and we apply this model to our thermal lithium interferometer. We are thus able to explain the observed dependence of the fringe visibility with the diffraction order. The dynamical model developed in the present paper should be very useful to further reduce this phase noise in atom interferometers and this reduction should open the way to improved interferometers.

•Apr 5, 2006•8 citations

Can optimised pulses improve the sensitivity of atom interferometers?

Jack Saywell, Max Carey, Nikolaos Dedes +2 more

The sensitivity of atom interferometers depends on the fidelity of the light pulses used as beamsplitters and mirrors. Atom interferometers typically employ pulses that affect π/2 and π fractional Rabi oscillations, the fidelities of which are reduced when there are variations in atomic velocity and laser intensity. We have previously demonstrated the application of optimal control theory to design pulses more robust to such errors; however, if these variations exhibit a time dependence over periods on the order of the interferometer duration then phase shifts can be introduced in the final fringe that potentially reduce the sensitivity. In this paper, we explain why care must be taken when optimising interferometer pulse sequences to ensure that phase shifts arising from inter-pulse variations are not significantly increased. We show that these phase shifts can in fact be minimised by choosing an appropriate measure of individual pulse fidelity.

Quantum Technology: Driving Commercialisation of an Enabling Science•Oct 6, 2021•1 citation

Composite-Fringe Atom Interferometry for High-Dynamic-Range Sensing

Chen Avinadav, Dimitry Yankelev, Ofer Firstenberg +1 more

Atom interferometers offer excellent sensitivity to gravitational and inertial signals but have limited dynamic range. We introduce a scheme that improves this trade-off by a factor of 50 using composite fringes, obtained from sets of measurements with slightly varying interrogation times, as in a moir\'e effect. We analyze analytically the performance gain in this approach and the trade-offs it entails between sensitivity, dynamic range, and bandwidth, and we experimentally validate the analysis over a wide range of parameters. Combining composite-fringe measurements with a particle-filter estimation protocol, we demonstrate continuous tracking of a rapidly varying signal over a span 2 orders of magnitude larger than the dynamic range of a traditional atom interferometer.

arXiv:1912.12304•Physical Review Applied•May 21, 2020•18 citations
We investigated the sensitivities of atom interferometers in the usual fringe-scanning method (FSM) versus the fringe-locking method (FLM). The theoretical analysis shows that for typical noises in atom interferometers, the FSM will degrade the sensitivity while the FLM does not. The sensitivity-improvement factor of the FLM over the FSM depends on the type of noises, which is validated by numerical simulations. The detailed quantitative analysis on this fundamental issue is presented, and our analysis is readily extendable to other kinds of noises as well as other fringe shapes in addition to a cosine one.
We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.
The sensitivity of an interferometer depends on its readout scheme. However, little attention has been paid to the readout schemes of atom interferometers from the viewpoint of their sensitivity. The difference in sensitivity between readout schemes or their optimization has not been considered in the literature. Herein we analytically calculate the sensitivities of an atom interferometer with typical readout schemes by applying the two-photon formalism, which was developed for optical interferometers to deal with quantum noise. Our calculations reveal that by using sinusoidal phase modulation, the sensitivity can surpass that obtained by the conventional phase sweeping scheme. The superiority of this phase modulation scheme for both cold and thermal atomic beams is demonstrated. In addition, we show that the phase modulation scheme is advantageous for atom-flux fluctuation and resists atom-flux drift. This study performs a general analysis of the sensitivity of atom interferometers and identifies an advantageous readout scheme.
The high inertial sensitivity of atom interferometers has been used to build accelerometers and gyrometers but this sensitivity makes these interferometers very sensitive to the laboratory seismic noise. This seismic noise induces a phase noise which is large enough to reduce the fringe visibility in many cases. We develop here a model calculation of this phase noise in the case of Mach-Zehnder atom interferometers and we apply this model to our thermal lithium interferometer. We are thus able to explain the observed dependence of the fringe visibility with the diffraction order. The dynamical model developed in the present paper should be very useful to further reduce this phase noise in atom interferometers and this reduction should open the way to improved interferometers.
The sensitivity of atom interferometers depends on the fidelity of the light pulses used as beamsplitters and mirrors. Atom interferometers typically employ pulses that affect π/2 and π fractional Rabi oscillations, the fidelities of which are reduced when there are variations in atomic velocity and laser intensity. We have previously demonstrated the application of optimal control theory to design pulses more robust to such errors; however, if these variations exhibit a time dependence over periods on the order of the interferometer duration then phase shifts can be introduced in the final fringe that potentially reduce the sensitivity. In this paper, we explain why care must be taken when optimising interferometer pulse sequences to ensure that phase shifts arising from inter-pulse variations are not significantly increased. We show that these phase shifts can in fact be minimised by choosing an appropriate measure of individual pulse fidelity.
Atom interferometers offer excellent sensitivity to gravitational and inertial signals but have limited dynamic range. We introduce a scheme that improves this trade-off by a factor of 50 using composite fringes, obtained from sets of measurements with slightly varying interrogation times, as in a moir\'e effect. We analyze analytically the performance gain in this approach and the trade-offs it entails between sensitivity, dynamic range, and bandwidth, and we experimentally validate the analysis over a wide range of parameters. Combining composite-fringe measurements with a particle-filter estimation protocol, we demonstrate continuous tracking of a rapidly varying signal over a span 2 orders of magnitude larger than the dynamic range of a traditional atom interferometer.