Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1603.01321

Fringe-locking method for the weak equivalence principle test by simultaneous dual-species atom interferometers

Xiao‐Chun Duan, Xiao-Bing Deng, Dekai Mao, Min-Kang Zhou, Cheng-Gang Shao, Zhong-Kun Hu

Published Mar 4, 2016• 0 citations
arXivHTMLPDF

Abstract

We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.

DOI
10.48550/arxiv.1603.01321

Related papers

Correlative methods for dual-species quantum tests of the weak equivalence principle

B. Barrett, Laura Antoni‐Micollier, Laure Chichet +5 more

Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.

arXiv:1503.08423•New Journal of Physics•Aug 27, 2015•64 citations

Characterization of a simultaneous dual-species atom interferometer for a quantum test of the weak equivalence principle

Alexis Bonnin, Nassim Zahzam, Yannick Bidel +1 more

We present here the performance of a simultaneous dual-species matter-wave accelerometer for measuring the differential acceleration between two different atomic species ($^{87}\mathrm{Rb}$ and $^{85}\mathrm{Rb}$). We study the expression and the extraction of the differential phase from the interferometer output. The differential accelerometer reaches a short-term sensitivity of $1.23\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}g/\sqrt{\mathrm{Hz}}$ limited by the detection noise and a resolution of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}g$ after 11 000 s, a very high sensitivity using a dual-species atom interferometer. Thanks to the simultaneous measurement, such resolution levels can still be achieved even with vibration levels up to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}g$, corresponding to a common-mode vibration noise rejection ratio of 94 dB (rejection factor of 50 000). These results prove the ability of such atom sensors for realizing a quantum-based test of the weak equivalence principle at a level of $\ensuremath{\eta}\ensuremath{\sim}{10}^{\ensuremath{-}9}$ even with high vibration levels and a compact sensor.

arXiv:1506.06535•Physical Review A•Aug 18, 2015•51 citations

In-orbit Test of the Weak Equivalence Principle with Atom Interferometry

Dan-Fang Zhang, Jing-Ting Li, Wen-Zhang Wang +22 more

The Weak Equivalence Principle (WEP) is a central pillar of general relativity. Its precise test with quantum systems in space offers a unique window onto new physics. Here we report the first in-orbit quantum test of the WEP. A dual-species (85Rb/87Rb) atom interferometer is realized aboard the China Space Station. Methods of platform motion suppression, fluorescence detection switching, and two-photon detuning switching are developed to eliminate phase noise and improve measurement accuracy. A test uncertainty of 2.8*10-8 is obtained from 280 days of WEP test data, and a test result of (-3.1+/-4.6)*10-7 is achieved after error estimation. This improves prior atom-interferometric WEP tests in microgravity by three orders of magnitude. This work paves the way for space-borne quantum inertial sensors and their application to future fundamental physics in space.

physics.atom-phCross-listedarXiv:2603.22981•Science Advances•Mar 25, 2026•1 citation

Proposal for a Quantum Test of the Weak Equivalence Principle with Entangled Atomic Species

Rémi Geiger, Michael Trupke

We propose an experiment to test the weak equivalence principle (WEP) with a test mass consisting of two entangled atoms of different species. In the proposed experiment, a coherent measurement of the differential gravity acceleration between the two atomic species is considered, by entangling two atom interferometers operating on the two species. The entanglement between the two atoms is heralded at the initial beam splitter of the interferometers through the detection of a single photon emitted by either of the atoms, together with the impossibility of distinguishing which atom emitted the photon. In contrast to current and proposed tests of the WEP, our proposal explores the validity of the WEP in a regime where the two particles involved in the differential gravity acceleration measurement are not classically independent, but entangled. We propose an experimental implementation using ^{85}Rb and ^{87}Rb atoms entangled by a vacuum stimulated rapid adiabatic passage protocol implemented in a high-finesse optical cavity. We show that an accuracy below 10^{-7} on the Eötvös parameter can be achieved.

arXiv:1801.08604•Physical Review Letters•Jan 25, 2018•76 citations

Common-mode noise rejection using fringe-locking method in WEP test by simultaneous dual-species atom interferometers

Xiao-Bing Deng, Xiao‐Chun Duan, Dekai Mao +3 more

Common-mode noise rejection using fringe-locking method in WEP test by simultaneous dual-species atom interferometers* , Deng, Xiao-Bing, Duan, Xiao-Chun, Mao, De-Kai, Zhou, Min-Kang, Shao, Cheng-Gang, Hu, Zhong-Kun

Chinese Physics B•Apr 1, 2017•4 citations

Simultaneous dual-species matter-wave accelerometer

Alexis Bonnin, Nassim Zahzam, Yannick Bidel +1 more

We report the realization of a matter-wave interferometer based on Raman transitions which simultaneously interrogates two different atomic species (${}^{87}$Rb and ${}^{85}$Rb). The simultaneous aspect of our experiment presents encouraging preliminary results for future dual-species atom interferometry projects and seems very promising by taking advantage of a differential acceleration measurement. Indeed, the resolution of our differential accelerometer remains lower than $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ even with vibration levels up to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ thanks to common-mode vibration noise rejection. An atom-based test of the weak equivalence principle has also been carried out leading to a differential free fall measurement between both isotopes of $\ensuremath{\Delta}g/g=(1.2\ifmmode\pm\else\textpm\fi{}3.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$.

arXiv:1307.2734•Physical Review A•Oct 11, 2013•175 citations
We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the extraction of the phase shift for atom interferometers is linearized. For the simultaneous interferometers, this linearization enables a good common-mode rejection of vibration noise, which is usually the main limit for high precision WEP tests of dual-species kind. We note that this method also allows for an unbiased determination of the gravity accelerations difference, which meanwhile is readily to be implemented.
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.
We present here the performance of a simultaneous dual-species matter-wave accelerometer for measuring the differential acceleration between two different atomic species (87Rb^{87}\mathrm{Rb}87Rb and 85Rb^{85}\mathrm{Rb}85Rb). We study the expression and the extraction of the differential phase from the interferometer output. The differential accelerometer reaches a short-term sensitivity of $1.23\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}g/\sqrt{\mathrm{Hz}}$ limited by the detection noise and a resolution of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}g$ after 11 000 s, a very high sensitivity using a dual-species atom interferometer. Thanks to the simultaneous measurement, such resolution levels can still be achieved even with vibration levels up to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}g$, corresponding to a common-mode vibration noise rejection ratio of 94 dB (rejection factor of 50 000). These results prove the ability of such atom sensors for realizing a quantum-based test of the weak equivalence principle at a level of $\ensuremath{\eta}\ensuremath{\sim}{10}^{\ensuremath{-}9}$ even with high vibration levels and a compact sensor.
The Weak Equivalence Principle (WEP) is a central pillar of general relativity. Its precise test with quantum systems in space offers a unique window onto new physics. Here we report the first in-orbit quantum test of the WEP. A dual-species (85Rb/87Rb) atom interferometer is realized aboard the China Space Station. Methods of platform motion suppression, fluorescence detection switching, and two-photon detuning switching are developed to eliminate phase noise and improve measurement accuracy. A test uncertainty of 2.8*10-8 is obtained from 280 days of WEP test data, and a test result of (-3.1+/-4.6)*10-7 is achieved after error estimation. This improves prior atom-interferometric WEP tests in microgravity by three orders of magnitude. This work paves the way for space-borne quantum inertial sensors and their application to future fundamental physics in space.
We propose an experiment to test the weak equivalence principle (WEP) with a test mass consisting of two entangled atoms of different species. In the proposed experiment, a coherent measurement of the differential gravity acceleration between the two atomic species is considered, by entangling two atom interferometers operating on the two species. The entanglement between the two atoms is heralded at the initial beam splitter of the interferometers through the detection of a single photon emitted by either of the atoms, together with the impossibility of distinguishing which atom emitted the photon. In contrast to current and proposed tests of the WEP, our proposal explores the validity of the WEP in a regime where the two particles involved in the differential gravity acceleration measurement are not classically independent, but entangled. We propose an experimental implementation using ^{85}Rb and ^{87}Rb atoms entangled by a vacuum stimulated rapid adiabatic passage protocol implemented in a high-finesse optical cavity. We show that an accuracy below 10^{-7} on the Eötvös parameter can be achieved.
We report the realization of a matter-wave interferometer based on Raman transitions which simultaneously interrogates two different atomic species (87{}^{87}87Rb and 85{}^{85}85Rb). The simultaneous aspect of our experiment presents encouraging preliminary results for future dual-species atom interferometry projects and seems very promising by taking advantage of a differential acceleration measurement. Indeed, the resolution of our differential accelerometer remains lower than $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ even with vibration levels up to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ thanks to common-mode vibration noise rejection. An atom-based test of the weak equivalence principle has also been carried out leading to a differential free fall measurement between both isotopes of $\ensuremath{\Delta}g/g=(1.2\ifmmode\pm\else\textpm\fi{}3.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$.