Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE/ION Position Location and Navigation Symposium

Improvement of atom interferometer by rejecting typical noise sources

Wei Hong Gao, Lin Zhang, Qian Li, Zhuo Wang

Published Apr 1, 2016• 0 citations
Publisher

Abstract

In this paper, we review the progress of atom interferometer sensors. Previous research institutions focused on how to improve the atom interferometers as an independent sensor. We have shown the atom interferometry and the sensitivity function which is helpful on noise evaluation, and demonstrated some rejection approaches of laser noise, vibration noise, and detection noise after comparison.

DOI
10.1109/plans.2016.7479764

Related papers

Fluorescence detection at the atom shot noise limit for atom interferometry

E Rocco, R N Palmer, T. Valenzuela +3 more

Atom interferometers (AIs) are promising tools for precision measurement with applications ranging from geophysical exploration and tests of the equivalence principle of general relativity to the detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs, and we theoretically analyze the relative influence of various scheme dependent noise sources and the technical challenges affecting the detection. We show that for the typical conditions under which an AI operates, simultaneous fluorescence detection with a charge-coupled device sensor is the optimal imaging scheme. We extract the laser beam parameters such as detuning, intensity, and duration required for reaching the atom shot noise limit.

arXiv:1404.7117•New Journal of Physics•Sep 25, 2014•36 citations

Atom Interferometry and Inertial Sensors

Philippe Bouyer

Atomic quantum sensors are a major breakthrough in the technology of time and frequency standards as well as ultra-precise sensing and monitoring of accelerations and rotations. They apply a new kind of optics based on matter waves. Today, atomic clocks are the standard for time and frequency measurement at the highest precisions. Inertial and rotational sensors using atom interferometers have already shown similar potential for replacing state-of-the-art sensors in other fields. With Bose-Einstein condensates, also refered as atom lasers, the traditional experiments with atom interferometers can be greatly improved. Testing of fundamental principles, studies of atomic properties, applications as inertial sensors, and measurements of fundamental constants can benefit from the brightness (intensity and small momentum spread) of these coherent sources. In addition, the coherence properties of condensates may also allow BEC based atom interferometers to approach the Heisenberg detection limit. This corresponds to a measurement precision which scales like 1/N for N atoms and not like 1 / N as for independent measurements on N atoms.

Frontiers in Optics•Jan 1, 2007•0 citations

GENERATION OF SQUEEZED LIGHT FOR USE WITH ATOM INTERFEROMETERS

da Cruz Araujo Vieira, Renata

Atom interferometers possess great potential as sensitive and stable acceleration and rotation sensors. Currently, the DoD is interested in leveraging atom interferometry research to improve inertial sensors and develop portable, compact devices based on atom interferometers with strategic-grade performance. Typical atom interferometers measure the acceleration or rotation signal with an on-resonance detection laser field, but these laser fields have inherent noise that degrades the signal-to-noise ratio. The laser noise in one quadrature of the field can be reduced below the so-called shot noise limit at the expense of the other quadrature. Fields with this property are called “squeezed fields.” Although lowering the noise in one quadrature increases noise in the other quadrature (due to Heisenberg’s uncertainty principle), the noise in the other quadrature can be made irrelevant by designing a detection scheme that does not use that quadrature. By reducing light-source noise, atom interferometer measurement precision can be increased. This thesis aims to establish the groundwork for creating squeezed light to be used for the detection of atoms in the ground or excited state of the NPS Atom Interferometry Laboratory atom interferometer.

•Dec 1, 2020•0 citations

Inertial noise post-correction in atom interferometers measuring the local gravitational acceleration

L. Richardson

Exploiting the quantum nature of atoms through the use of matter-wave interferometry has lead to the development of devices sensitive to, among other things, the local gravitational acceleration. Measurements of the gravitational acceleration have applications ranging from detection of subterranean density di erences to observation of general relativistic e ects. Light-pulse atom interferometers provide an absolute measurement of the gravitational acceleration with a sensitivity competitive and even surpassing the performance of classical sensors. The advantages of atom interferometers as inertial measurement devices have lead to e orts in increasing sensitivity and decreasing the physical dimensions of the measurement head, allowing them to be more transportable for eld use applications. With increasing sensitivity, it becomes more critical to address the noise source limitations a ecting the measurement, speci cally the in uence of ground motion on measurements. Vibrations coupling into the inertial reference add a time varying phase shift uncommon to the paths of the interferometer. This limitation is especially pertinent to transportable atom gravimeters measuring in the eld where inertial noise is typically far higher than in relatively quiet laboratory environments. Within this work, implementation and demonstration of inertial noise post-correction in an atom interferometer is shown within low inertial noise environments and simulated strong motion environments. For a high pulse separation time atom interferometer (T = 78 ms) post-correction yielded an increase in the short term stability from 4.4 x 10 ̄6 m/s2/√Hz to 9.2 x 10 ̄7 m/s2/√Hz. This method was reproduced with a di erent motion sensor to perform post-correction in a high motion environment, generated by introducing additional movement onto the inertial reference. By performing post-correction in the high motion environment, we were able to show an increase of short term stability of γ = 73.8. Current limitations to the post-correction resulted from self noise resolution limitations and spectral resolutions limitations. Beyond corrections with commercially available sensors, this work demonstrates the rst post-correction with a next generation compact optomechanical sensor. This optomechanical sensor is formed from monolithic fused silica capable of sensitively measuring accelerations of a harmonic oscillator test mass, which can be read-out optically. This novel motion sensor has the advantage to any previously shown sensor used for post-correction in the capacity that it is vacuum compatible, insensitive to magnetic elds and has the potential to be implemented directly into the inertial reference. In this work, inertial noise post-correction in a simulated high motion environment is shown, correcting from a short term stability of 8 x 10 ̄3 m/s2/√Hz to 5 x 10 ̄4 m/s2/√Hz. Post-correction was limited by the parasitic cavities within the ber required for optical read-out of the harmonic oscillator displacement and intensity noise uctuations of the source laser. The results shown within this work are congruent with previous works on atom chip gravimeters, both of which help move towards portable hand-held gravimeter measurement heads capable of sensitive inertial measurement.

•Jan 1, 2019•9 citations

High accuracy inertial measurement based on atom interferometer

Zhao Chang-shan

The atom interferometer was reviewed and its recent development and progress were reported.The interferometer,based on the theory of laser cooling,trapping and manipulation of atom,utilizes the atomic particles as free fall test masses to measure the experienced inertial force of the apparatus.Many tests show that the novel inertial sensors can measure the rotation and acceleration of apparatus with unprecedented sensitivity and precision,and distinguish them by counter-propagating beams of atoms.The atom interferometer can get extensive application in inertial measurement based on them due to its compactness and long-term stability.

Journal of Chinese Inertial Technology•Jan 1, 2008•0 citations

Hybrid quantum sensing using an optomechanical resonator coupled atom interferometer

Ashwin Rajagopalan

Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.

•Jan 1, 2026•0 citations
In this paper, we review the progress of atom interferometer sensors. Previous research institutions focused on how to improve the atom interferometers as an independent sensor. We have shown the atom interferometry and the sensitivity function which is helpful on noise evaluation, and demonstrated some rejection approaches of laser noise, vibration noise, and detection noise after comparison.
Atom interferometers (AIs) are promising tools for precision measurement with applications ranging from geophysical exploration and tests of the equivalence principle of general relativity to the detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs, and we theoretically analyze the relative influence of various scheme dependent noise sources and the technical challenges affecting the detection. We show that for the typical conditions under which an AI operates, simultaneous fluorescence detection with a charge-coupled device sensor is the optimal imaging scheme. We extract the laser beam parameters such as detuning, intensity, and duration required for reaching the atom shot noise limit.
Atomic quantum sensors are a major breakthrough in the technology of time and frequency standards as well as ultra-precise sensing and monitoring of accelerations and rotations. They apply a new kind of optics based on matter waves. Today, atomic clocks are the standard for time and frequency measurement at the highest precisions. Inertial and rotational sensors using atom interferometers have already shown similar potential for replacing state-of-the-art sensors in other fields. With Bose-Einstein condensates, also refered as atom lasers, the traditional experiments with atom interferometers can be greatly improved. Testing of fundamental principles, studies of atomic properties, applications as inertial sensors, and measurements of fundamental constants can benefit from the brightness (intensity and small momentum spread) of these coherent sources. In addition, the coherence properties of condensates may also allow BEC based atom interferometers to approach the Heisenberg detection limit. This corresponds to a measurement precision which scales like 1/N for N atoms and not like 1 / N as for independent measurements on N atoms.
Atom interferometers possess great potential as sensitive and stable acceleration and rotation sensors. Currently, the DoD is interested in leveraging atom interferometry research to improve inertial sensors and develop portable, compact devices based on atom interferometers with strategic-grade performance. Typical atom interferometers measure the acceleration or rotation signal with an on-resonance detection laser field, but these laser fields have inherent noise that degrades the signal-to-noise ratio. The laser noise in one quadrature of the field can be reduced below the so-called shot noise limit at the expense of the other quadrature. Fields with this property are called “squeezed fields.” Although lowering the noise in one quadrature increases noise in the other quadrature (due to Heisenberg’s uncertainty principle), the noise in the other quadrature can be made irrelevant by designing a detection scheme that does not use that quadrature. By reducing light-source noise, atom interferometer measurement precision can be increased. This thesis aims to establish the groundwork for creating squeezed light to be used for the detection of atoms in the ground or excited state of the NPS Atom Interferometry Laboratory atom interferometer.
Exploiting the quantum nature of atoms through the use of matter-wave interferometry has lead to the development of devices sensitive to, among other things, the local gravitational acceleration. Measurements of the gravitational acceleration have applications ranging from detection of subterranean density di erences to observation of general relativistic e ects. Light-pulse atom interferometers provide an absolute measurement of the gravitational acceleration with a sensitivity competitive and even surpassing the performance of classical sensors. The advantages of atom interferometers as inertial measurement devices have lead to e orts in increasing sensitivity and decreasing the physical dimensions of the measurement head, allowing them to be more transportable for eld use applications. With increasing sensitivity, it becomes more critical to address the noise source limitations a ecting the measurement, speci cally the in uence of ground motion on measurements. Vibrations coupling into the inertial reference add a time varying phase shift uncommon to the paths of the interferometer. This limitation is especially pertinent to transportable atom gravimeters measuring in the eld where inertial noise is typically far higher than in relatively quiet laboratory environments. Within this work, implementation and demonstration of inertial noise post-correction in an atom interferometer is shown within low inertial noise environments and simulated strong motion environments. For a high pulse separation time atom interferometer (T = 78 ms) post-correction yielded an increase in the short term stability from 4.4 x 10 ̄6 m/s2/√Hz to 9.2 x 10 ̄7 m/s2/√Hz. This method was reproduced with a di erent motion sensor to perform post-correction in a high motion environment, generated by introducing additional movement onto the inertial reference. By performing post-correction in the high motion environment, we were able to show an increase of short term stability of γ = 73.8. Current limitations to the post-correction resulted from self noise resolution limitations and spectral resolutions limitations. Beyond corrections with commercially available sensors, this work demonstrates the rst post-correction with a next generation compact optomechanical sensor. This optomechanical sensor is formed from monolithic fused silica capable of sensitively measuring accelerations of a harmonic oscillator test mass, which can be read-out optically. This novel motion sensor has the advantage to any previously shown sensor used for post-correction in the capacity that it is vacuum compatible, insensitive to magnetic elds and has the potential to be implemented directly into the inertial reference. In this work, inertial noise post-correction in a simulated high motion environment is shown, correcting from a short term stability of 8 x 10 ̄3 m/s2/√Hz to 5 x 10 ̄4 m/s2/√Hz. Post-correction was limited by the parasitic cavities within the ber required for optical read-out of the harmonic oscillator displacement and intensity noise uctuations of the source laser. The results shown within this work are congruent with previous works on atom chip gravimeters, both of which help move towards portable hand-held gravimeter measurement heads capable of sensitive inertial measurement.
The atom interferometer was reviewed and its recent development and progress were reported.The interferometer,based on the theory of laser cooling,trapping and manipulation of atom,utilizes the atomic particles as free fall test masses to measure the experienced inertial force of the apparatus.Many tests show that the novel inertial sensors can measure the rotation and acceleration of apparatus with unprecedented sensitivity and precision,and distinguish them by counter-propagating beams of atoms.The atom interferometer can get extensive application in inertial measurement based on them due to its compactness and long-term stability.
Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.