Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Chinese Inertial Technology

High accuracy inertial measurement based on atom interferometer

Zhao Chang-shan

Published Jan 1, 2008• 0 citations
OpenAlex

Abstract

The atom interferometer was reviewed and its recent development and progress were reported.The interferometer,based on the theory of laser cooling,trapping and manipulation of atom,utilizes the atomic particles as free fall test masses to measure the experienced inertial force of the apparatus.Many tests show that the novel inertial sensors can measure the rotation and acceleration of apparatus with unprecedented sensitivity and precision,and distinguish them by counter-propagating beams of atoms.The atom interferometer can get extensive application in inertial measurement based on them due to its compactness and long-term stability.

Related papers

Progress towards a space-borne quantum gravity gradiometer

Nan Yu, James M. Kohel, Jaime Ramirez-Serrano +3 more

Quantum interferometer gravity gradiometer for 3D mapping is a project for developing the technology of atom interferometer-based gravity sensor in space. The atom interferometer utilizes atomic particles as free fall test masses to measure inertial forces with unprecedented sensitivity and precision. It also allows measurements of the gravity gradient tensor components for 3D mapping of subsurface mass distribution. The overall approach is based on recent advances of laser cooling and manipulation of atoms in atomic and optical physics. Atom interferometers have been demonstrated in research laboratories for gravity and gravity gradient measurements. In this approach, atoms are first laser cooled to micro-kelvin temperatures. Then they are allowed to freefall in vacuum as true drag-free test masses. During the free fall, a sequence of laser pulses is used to split and recombine the atom waves to realize the interferometric measurements. We have demonstrated atom interferometer operation in the Phase I period, and we are implementing the second generation for a complete gradiometer demonstration unit in the laboratory. Along with this development, we are developing technologies at component levels that will be more suited for realization of a space instrument. We will present an update of these developments and discuss the future directions of the quantum gravity gradiometer project.

•Jun 22, 2004•6 citations

Mobile and remote inertial sensing with atom interferometers

B. Barrett, P.-A. Gominet, Etienne Cantin +6 more

The past three decades have shown dramatic progress in the ability to manipulate and coherently control the motion of atoms. This exquisite control offers the prospect of a new generation of inertial sensors with unprecedented sensitivity and accuracy, which will be important for both fundamental and applied science. In this article, we review some of our recent results regarding the application of atom interferometry to inertial measurements using compact, mobile sensors. This includes some of the first interferometer measurements with cold $^{39}$K atoms, which is a major step toward achieving a transportable, dual-species interferometer with rubidium and potassium for equivalence principle tests. We also discuss future applications of this technology, such as remote sensing of geophysical effects, gravitational wave detection, and precise tests of the weak equivalence principle in Space.

arXiv:1311.7033•Nov 27, 2013•25 citations

A transportable cold atom inertial sensor for space applications

Rémi Geiger, Guillaume Stern, Patrick Cheinet +7 more

Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).

International Conference on Space Optics (ICSO)•Nov 20, 2017•2 citations

Mobile and remote inertial sensing with atom interferometry

B. Barrett, P.-A. Gominet, Etienne Cantin +5 more

The past three decades have shown dramatic progress in the ability to manipulate and coherently control the motion of atoms. This exquisite control offers the prospect of a new generation of inertial sensors with unprecedented sensitivity and accuracy, which will be important for both fundamental and applied science. In this article, we review some of our recent results regarding the application of atom interferometry to inertial measurements using compact, mobile sensors. This includes some of the first interferometer measurements with cold $^{39}$K atoms, which is a major step toward achieving a transportable, dual-species interferometer with rubidium and potassium for equivalence principle tests. We also discuss future applications of this technology, such as remote sensing of geophysical effects, gravitational wave detection, and precise tests of the weak equivalence principle in Space.

•Jan 1, 2014•5 citations

An atom interferometer for measuring horizontal accelerations

Jimmy Stammers

Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.

•Nov 1, 2018•6 citations

Atom interferometer inertial force sensors

T. L. Gustavson, Arnaud Landragin, J. M. McGuirk +2 more

Summary form only given. Atom interferometer inertial force sensors offer the prospect of unprecedented performance for rotation, acceleration and gravity gradient measurements. The basic sensor operating principle is illustrated.

Quantum Electronics and Laser Science Conference•Jan 20, 2003•2 citations
The atom interferometer was reviewed and its recent development and progress were reported.The interferometer,based on the theory of laser cooling,trapping and manipulation of atom,utilizes the atomic particles as free fall test masses to measure the experienced inertial force of the apparatus.Many tests show that the novel inertial sensors can measure the rotation and acceleration of apparatus with unprecedented sensitivity and precision,and distinguish them by counter-propagating beams of atoms.The atom interferometer can get extensive application in inertial measurement based on them due to its compactness and long-term stability.
Quantum interferometer gravity gradiometer for 3D mapping is a project for developing the technology of atom interferometer-based gravity sensor in space. The atom interferometer utilizes atomic particles as free fall test masses to measure inertial forces with unprecedented sensitivity and precision. It also allows measurements of the gravity gradient tensor components for 3D mapping of subsurface mass distribution. The overall approach is based on recent advances of laser cooling and manipulation of atoms in atomic and optical physics. Atom interferometers have been demonstrated in research laboratories for gravity and gravity gradient measurements. In this approach, atoms are first laser cooled to micro-kelvin temperatures. Then they are allowed to freefall in vacuum as true drag-free test masses. During the free fall, a sequence of laser pulses is used to split and recombine the atom waves to realize the interferometric measurements. We have demonstrated atom interferometer operation in the Phase I period, and we are implementing the second generation for a complete gradiometer demonstration unit in the laboratory. Along with this development, we are developing technologies at component levels that will be more suited for realization of a space instrument. We will present an update of these developments and discuss the future directions of the quantum gravity gradiometer project.
The past three decades have shown dramatic progress in the ability to manipulate and coherently control the motion of atoms. This exquisite control offers the prospect of a new generation of inertial sensors with unprecedented sensitivity and accuracy, which will be important for both fundamental and applied science. In this article, we review some of our recent results regarding the application of atom interferometry to inertial measurements using compact, mobile sensors. This includes some of the first interferometer measurements with cold 39^{39}39K atoms, which is a major step toward achieving a transportable, dual-species interferometer with rubidium and potassium for equivalence principle tests. We also discuss future applications of this technology, such as remote sensing of geophysical effects, gravitational wave detection, and precise tests of the weak equivalence principle in Space.
Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).
The past three decades have shown dramatic progress in the ability to manipulate and coherently control the motion of atoms. This exquisite control offers the prospect of a new generation of inertial sensors with unprecedented sensitivity and accuracy, which will be important for both fundamental and applied science. In this article, we review some of our recent results regarding the application of atom interferometry to inertial measurements using compact, mobile sensors. This includes some of the first interferometer measurements with cold 39^{39}39K atoms, which is a major step toward achieving a transportable, dual-species interferometer with rubidium and potassium for equivalence principle tests. We also discuss future applications of this technology, such as remote sensing of geophysical effects, gravitational wave detection, and precise tests of the weak equivalence principle in Space.
Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.