Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

A microwave amplitude stabilization method for atomic clocks with Ramsey interrogation

Michele Gozzelino, Salvatore Micalizio, Filippo Levi, Aldo Godone, Claudio Eligio Calosso

Published Feb 9, 2018• 0 citations
OpenAlex

Abstract

We describe a method to stabilize the amplitude of the interrogating microwave field in compact atomic clocks working in a Ramsey approach. In this technique, we take advantage of the pulsed regime to use the atoms themselves as microwave amplitude discriminators. Specifically, in addition to the dependence on the microwave detuning, the atomic signal after the Ramsey interrogation acquires a dependence on the microwave pulse area (amplitude times duration) that can be exploited to implement an active stabilization of the microwave field amplitude, in a similar way in which the Ramsey clock signal is used to lock the local oscillator frequency to the atomic reference. This stabilization results in a reduced sensitivity of the clock frequency to microwave amplitude fluctuations that are transferred to the atoms through the cavity-pulling effect. The proposed technique is then effective to improve the clock stability and drift on medium and long term. We demonstrate the method for a vapor-cell clock working with a hot sample of atoms but it can be extended to cold-atom compact clocks.

Related papers

Microwave field amplitude stabilization using Ramsey spectroscopy signal

Michele Gozzelino, Aldo Godone, Salvatore Micalizio +2 more

We present a method to actively stabilize the amplitude of the microwave field which constitutes the probe for many state-of-the-art compact atomic clocks. The method applies to clocks working in pulsed operation, specifically with a Ramsey scheme. The proposed technique relies on information directly extracted from the clock atomic signal, as it computes the gradient in the two variables (amplitude and frequency) characterizing the probe field, instead of differentiating solely the frequency response, as in usual operation. Magnetic field sensing based on spectroscopy has proven to be a valuable tool for metrology and precise measurement field. We demonstrate the advantage of using the spectroscopic signal to stabilize the microwave field amplitude, in order to reach 10-15stability with compact clocks, by mitigating cavity-pulling shift effects.

European Frequency and Time Forum•Apr 1, 2018•0 citations

Ramsey Spectroscopy with Displaced Frequency Jumps

M. Shuker, J. W. Pollock, Rodolphe Boudot +4 more

Sophisticated Ramsey-based interrogation protocols using composite laser pulse sequences have been recently proposed to provide next-generation high-precision atomic clocks with a near perfect elimination of frequency shifts induced during the atom-probing field interaction. We propose here a simple alternative approach to the autobalanced Ramsey interrogation protocol and demonstrate its application to a cold-atom microwave clock based on coherent population trapping (CPT). The main originality of the method, based on two consecutive Ramsey sequences with different dark periods, is to sample the central Ramsey fringes with frequency jumps finely adjusted by an additional frequency-displacement concomitant parameter, scaling as the inverse of the dark period. The advantage of this displaced frequency-jump Ramsey method is that the local oscillator (LO) frequency is used as a single physical variable to control both servo loops of the sequence, simplifying its implementation and avoiding noise associated with controlling the LO phase. When tested using a CPT cold-atom clock, the DFJR scheme reduces the sensitivity of the clock frequency to variations of the light shifts by more than an order of magnitude compared with the standard Ramsey interrogation. This simple method can be applied in a wide variety of Ramsey-spectroscopy based applications including frequency metrology with CPT-based and optical atomic clocks, mass spectrometry, and precision spectroscopy.

arXiv:1812.01703•Physical Review Letters•Mar 19, 2019•38 citations

Loaded Microwave Cavity for Compact Vapor-Cell Clocks

Michele Gozzelino, Salvatore Micalizio, Claudio Eligio Calosso +3 more

Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this article, we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The loaded cavity resonating at 6.83 GHz has an external volume of only 35 cm3and accommodates a vapor cell with 0.9-cm3inner volume. The proposed design aims at strongly reducing the core of the atomic clock, maintaining, at the same time, high-performing short-term stability ($\sigma _{y}{(}\tau {)} \leq {5}\times {10}^{-{13}} \,\tau ^{-{1}/{2}}$ standard Allan deviation). The proposed structure is characterized in terms of microwave field uniformity and atom-field coupling with the aid of finite-element calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is, thus, a viable design option for miniaturized microwave clocks.

arXiv:2005.10159•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jul 23, 2020•9 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•17 citations

Reduction of light shifts in a cold-atom CPT clock

Maojie Li, Zhu Ma, Jiatao Wu +5 more

Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 23, 2024•3 citations

Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard

Filippo Levi, Claudio Eligio Calosso, A. Godone +1 more

In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation
We describe a method to stabilize the amplitude of the interrogating microwave field in compact atomic clocks working in a Ramsey approach. In this technique, we take advantage of the pulsed regime to use the atoms themselves as microwave amplitude discriminators. Specifically, in addition to the dependence on the microwave detuning, the atomic signal after the Ramsey interrogation acquires a dependence on the microwave pulse area (amplitude times duration) that can be exploited to implement an active stabilization of the microwave field amplitude, in a similar way in which the Ramsey clock signal is used to lock the local oscillator frequency to the atomic reference. This stabilization results in a reduced sensitivity of the clock frequency to microwave amplitude fluctuations that are transferred to the atoms through the cavity-pulling effect. The proposed technique is then effective to improve the clock stability and drift on medium and long term. We demonstrate the method for a vapor-cell clock working with a hot sample of atoms but it can be extended to cold-atom compact clocks.
We present a method to actively stabilize the amplitude of the microwave field which constitutes the probe for many state-of-the-art compact atomic clocks. The method applies to clocks working in pulsed operation, specifically with a Ramsey scheme. The proposed technique relies on information directly extracted from the clock atomic signal, as it computes the gradient in the two variables (amplitude and frequency) characterizing the probe field, instead of differentiating solely the frequency response, as in usual operation. Magnetic field sensing based on spectroscopy has proven to be a valuable tool for metrology and precise measurement field. We demonstrate the advantage of using the spectroscopic signal to stabilize the microwave field amplitude, in order to reach 10-15stability with compact clocks, by mitigating cavity-pulling shift effects.
Sophisticated Ramsey-based interrogation protocols using composite laser pulse sequences have been recently proposed to provide next-generation high-precision atomic clocks with a near perfect elimination of frequency shifts induced during the atom-probing field interaction. We propose here a simple alternative approach to the autobalanced Ramsey interrogation protocol and demonstrate its application to a cold-atom microwave clock based on coherent population trapping (CPT). The main originality of the method, based on two consecutive Ramsey sequences with different dark periods, is to sample the central Ramsey fringes with frequency jumps finely adjusted by an additional frequency-displacement concomitant parameter, scaling as the inverse of the dark period. The advantage of this displaced frequency-jump Ramsey method is that the local oscillator (LO) frequency is used as a single physical variable to control both servo loops of the sequence, simplifying its implementation and avoiding noise associated with controlling the LO phase. When tested using a CPT cold-atom clock, the DFJR scheme reduces the sensitivity of the clock frequency to variations of the light shifts by more than an order of magnitude compared with the standard Ramsey interrogation. This simple method can be applied in a wide variety of Ramsey-spectroscopy based applications including frequency metrology with CPT-based and optical atomic clocks, mass spectrometry, and precision spectroscopy.
Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this article, we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The loaded cavity resonating at 6.83 GHz has an external volume of only 35 cm3and accommodates a vapor cell with 0.9-cm3inner volume. The proposed design aims at strongly reducing the core of the atomic clock, maintaining, at the same time, high-performing short-term stability (σy(τ)≤5×10−13 τ−1/2\sigma _{y}{(}\tau {)} \leq {5}\times {10}^{-{13}} \,\tau ^{-{1}/{2}}σy​(τ)≤5×10−13τ−1/2 standard Allan deviation). The proposed structure is characterized in terms of microwave field uniformity and atom-field coupling with the aid of finite-element calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is, thus, a viable design option for miniaturized microwave clocks.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.
Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.
In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.