arXiv:2005.10159 · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control

Loaded Microwave Cavity for Compact Vapor-Cell Clocks

Michele Gozzelino, Salvatore Micalizio, Claudio Eligio Calosso, Aldo Godone, Haixiao Lin, Filippo Levi

Published Jul 23, 2020• 9 citations
arXivHTMLPDF

Abstract

Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this article, we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The loaded cavity resonating at 6.83 GHz has an external volume of only 35 cm3and accommodates a vapor cell with 0.9-cm3inner volume. The proposed design aims at strongly reducing the core of the atomic clock, maintaining, at the same time, high-performing short-term stability ($\sigma _{y}{(}\tau {)} \leq {5}\times {10}^{-{13}} \,\tau ^{-{1}/{2}}$ standard Allan deviation). The proposed structure is characterized in terms of microwave field uniformity and atom-field coupling with the aid of finite-element calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is, thus, a viable design option for miniaturized microwave clocks.

DOI
10.1109/tuffc.2020.3011604

Related papers

Laser-pumped high-performance compact gas-cell Rb standard with < 3×10−13 τ−1/2 stability

Thejesh Bandi, C. Affolderbach, G. Mileti +4 more

We demonstrate a high-performance laser-pumped rubidium-cell atomic frequency standard exhibiting a short-term stability of-13τ-1/2. The key components of this standard are a Rb vapor cell of 25mm diameter and a newly developed compact microwave resonator cavity. The overall volume of the clock's physics package - including the frequency-stabilized laser head and physics package - is <; 3 liters, which shows the potential of this compact clock for future portable applications.

European Frequency and Time Forum•Apr 1, 2012•1 citation

Double-resonance studies on compact, high-performance rubidium cell frequency standards

Thejesh Bandi Nagabhushan

This thesis presents experimental studies on continuous-wave (CW) laser-microwave double-resonance (DR) spectroscopy and metrology in rubidium (87Rb) vapor cells in view of new high-performance, compact Rb-cell atomic clocks. The Rb vapor cell is confined inside a magnetron-type cavity microwave resonator (MWR). The CW DR spectroscopy involves two resonant electromagnetic fields that are operated simultaneously to interrogate the atoms - the optical field to polarize the atoms by optical pumping, and the microwave field to drive the ground-state hyperfine clock transition that serves as an atomic frequency reference. Details on characterization of compact laser heads and microwave synthesizers used in this work are presented. The vapor cell standards are useful in our everyday lives for applications ranging from telecommunications, navigation, metrology etc. In view of improving the performances of the Rb cell standards, two different clock approaches were studied in detail: The first one is on use of vapor cells (1.4 cm3) whose inner walls are coated with anti-relaxation material. A first ever wall-coated cell clock was demonstrated with good short-term frequency stability. The medium- to long-term stability was found to be limited by the temperature coefficient (TC) of the coating material itself. This work gave the insight to important features to be considered in future anti-relaxation coating materials for atomic standards. The second novel approach involves using a bigger cell (12 cm3) within a newly developed, improved MWR towards a high-performance atomic standard. Adopting a larger cell gives a higher atomic Q-factor signal that improves the short-term clock stability. In this approach, the cell was filled with 87Rb and buffer gases. With this clock, we demonstrate the state-of-the-art short-term stability of <1.4×10−13 τ−1/2. Metrological quantitative measurements on parameters influencing the medium- to long-term stability were studied in view of next generation satellite navigation systems that demand a stability level of <1×10−14 at 10 4 s (equivalent to <1 ns/day). The potential of short-term stability and understanding of the limiting factors on medium- to long-term time scales demonstrated in this study pave the way for future work towards the commercialization of high-performance Rb atomic clocks for a variety of applications.

•Jan 1, 2013•2 citations

Demonstration of a high-performance pulsed optically pumped Rb clock based on a compact magnetron-type microwave cavity

Seung Won Kang, Mohammadreza Gharavipour, C. Affolderbach +2 more

We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.

Journal of Applied Physics•Mar 12, 2015•63 citations

Double-resonance studies on compact, high-performance rubidium cell frequency standards

Thejesh Bandi

This thesis presents experimental studies on continuous-wave (CW) laser-microwave double-resonance (DR) spectroscopy and metrology in rubidium (87Rb) vapor cells in view of new high-performance, compact Rb-cell atomic clocks. The Rb vapor cell is confined inside a magnetron-type cavity microwave resonator (MWR). The CW DR spectroscopy involves two resonant electromagnetic fields that are operated simultaneously to interrogate the atoms - the optical field to polarize the atoms by optical pumping, and the microwave field to drive the ground-state hyperfine clock transition that serves as an atomic frequency reference. Details on characterization of compact laser heads and microwave synthesizers used in this work are presented. The vapor cell standards are useful in our everyday lives for applications ranging from telecommunications, navigation, metrology etc. In view of improving the performances of the Rb cell standards, two different clock approaches were studied in detail: The first one is on use of vapor cells (1.4 cm3) whose inner walls are coated with anti-relaxation material. A first ever wall-coated cell clock was demonstrated with good short-term frequency stability. The medium- to long-term stability was found to be limited by the temperature coefficient (TC) of the coating material itself. This work gave the insight to important features to be considered in future anti-relaxation coating materials for atomic standards. The second novel approach involves using a bigger cell (12 cm3) within a newly developed, improved MWR towards a high-performance atomic standard. Adopting a larger cell gives a higher atomic Q-factor signal that improves the short-term clock stability. In this approach, the cell was filled with 87Rb and buffer gases. With this clock, we demonstrate the state-of-the-art short-term stability of <1.4×10−13 τ−1/2. Metrological quantitative measurements on parameters influencing the medium- to long-term stability were studied in view of next generation satellite navigation systems that demand a stability level of <1×10−14 at 10 4 s (equivalent to <1 ns/day). The potential of short-term stability and understanding of the limiting factors on medium- to long-term time scales demonstrated in this study pave the way for future work towards the commercialization of high-performance Rb atomic clocks for a variety of applications.

•Jan 1, 2013•4 citations

Study of additive manufactured microwave cavities for pulsed optically pumped atomic clock applications

C. Affolderbach, William Moreno, A. E. Ivanov +5 more

Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.

Applied Physics Letters•Mar 12, 2018•22 citations

A microwave amplitude stabilization method for atomic clocks with Ramsey interrogation

Michele Gozzelino, Salvatore Micalizio, Filippo Levi +2 more

We describe a method to stabilize the amplitude of the interrogating microwave field in compact atomic clocks working in a Ramsey approach. In this technique, we take advantage of the pulsed regime to use the atoms themselves as microwave amplitude discriminators. Specifically, in addition to the dependence on the microwave detuning, the atomic signal after the Ramsey interrogation acquires a dependence on the microwave pulse area (amplitude times duration) that can be exploited to implement an active stabilization of the microwave field amplitude, in a similar way in which the Ramsey clock signal is used to lock the local oscillator frequency to the atomic reference. This stabilization results in a reduced sensitivity of the clock frequency to microwave amplitude fluctuations that are transferred to the atoms through the cavity-pulling effect. The proposed technique is then effective to improve the clock stability and drift on medium and long term. We demonstrate the method for a vapor-cell clock working with a hot sample of atoms but it can be extended to cold-atom compact clocks.

•Feb 9, 2018•0 citations
Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this article, we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The loaded cavity resonating at 6.83 GHz has an external volume of only 35 cm3and accommodates a vapor cell with 0.9-cm3inner volume. The proposed design aims at strongly reducing the core of the atomic clock, maintaining, at the same time, high-performing short-term stability (σy(τ)≤5×10−13 τ−1/2\sigma _{y}{(}\tau {)} \leq {5}\times {10}^{-{13}} \,\tau ^{-{1}/{2}}σy​(τ)≤5×10−13τ−1/2 standard Allan deviation). The proposed structure is characterized in terms of microwave field uniformity and atom-field coupling with the aid of finite-element calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is, thus, a viable design option for miniaturized microwave clocks.
This thesis presents experimental studies on continuous-wave (CW) laser-microwave double-resonance (DR) spectroscopy and metrology in rubidium (87Rb) vapor cells in view of new high-performance, compact Rb-cell atomic clocks. The Rb vapor cell is confined inside a magnetron-type cavity microwave resonator (MWR). The CW DR spectroscopy involves two resonant electromagnetic fields that are operated simultaneously to interrogate the atoms - the optical field to polarize the atoms by optical pumping, and the microwave field to drive the ground-state hyperfine clock transition that serves as an atomic frequency reference. Details on characterization of compact laser heads and microwave synthesizers used in this work are presented. The vapor cell standards are useful in our everyday lives for applications ranging from telecommunications, navigation, metrology etc. In view of improving the performances of the Rb cell standards, two different clock approaches were studied in detail: The first one is on use of vapor cells (1.4 cm3) whose inner walls are coated with anti-relaxation material. A first ever wall-coated cell clock was demonstrated with good short-term frequency stability. The medium- to long-term stability was found to be limited by the temperature coefficient (TC) of the coating material itself. This work gave the insight to important features to be considered in future anti-relaxation coating materials for atomic standards. The second novel approach involves using a bigger cell (12 cm3) within a newly developed, improved MWR towards a high-performance atomic standard. Adopting a larger cell gives a higher atomic Q-factor signal that improves the short-term clock stability. In this approach, the cell was filled with 87Rb and buffer gases. With this clock, we demonstrate the state-of-the-art short-term stability of <1.4×10−13 τ−1/2. Metrological quantitative measurements on parameters influencing the medium- to long-term stability were studied in view of next generation satellite navigation systems that demand a stability level of <1×10−14 at 10 4 s (equivalent to <1 ns/day). The potential of short-term stability and understanding of the limiting factors on medium- to long-term time scales demonstrated in this study pave the way for future work towards the commercialization of high-performance Rb atomic clocks for a variety of applications.
We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.
This thesis presents experimental studies on continuous-wave (CW) laser-microwave double-resonance (DR) spectroscopy and metrology in rubidium (87Rb) vapor cells in view of new high-performance, compact Rb-cell atomic clocks. The Rb vapor cell is confined inside a magnetron-type cavity microwave resonator (MWR). The CW DR spectroscopy involves two resonant electromagnetic fields that are operated simultaneously to interrogate the atoms - the optical field to polarize the atoms by optical pumping, and the microwave field to drive the ground-state hyperfine clock transition that serves as an atomic frequency reference. Details on characterization of compact laser heads and microwave synthesizers used in this work are presented. The vapor cell standards are useful in our everyday lives for applications ranging from telecommunications, navigation, metrology etc. In view of improving the performances of the Rb cell standards, two different clock approaches were studied in detail: The first one is on use of vapor cells (1.4 cm3) whose inner walls are coated with anti-relaxation material. A first ever wall-coated cell clock was demonstrated with good short-term frequency stability. The medium- to long-term stability was found to be limited by the temperature coefficient (TC) of the coating material itself. This work gave the insight to important features to be considered in future anti-relaxation coating materials for atomic standards. The second novel approach involves using a bigger cell (12 cm3) within a newly developed, improved MWR towards a high-performance atomic standard. Adopting a larger cell gives a higher atomic Q-factor signal that improves the short-term clock stability. In this approach, the cell was filled with 87Rb and buffer gases. With this clock, we demonstrate the state-of-the-art short-term stability of <1.4×10−13 τ−1/2. Metrological quantitative measurements on parameters influencing the medium- to long-term stability were studied in view of next generation satellite navigation systems that demand a stability level of <1×10−14 at 10 4 s (equivalent to <1 ns/day). The potential of short-term stability and understanding of the limiting factors on medium- to long-term time scales demonstrated in this study pave the way for future work towards the commercialization of high-performance Rb atomic clocks for a variety of applications.
Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.
We describe a method to stabilize the amplitude of the interrogating microwave field in compact atomic clocks working in a Ramsey approach. In this technique, we take advantage of the pulsed regime to use the atoms themselves as microwave amplitude discriminators. Specifically, in addition to the dependence on the microwave detuning, the atomic signal after the Ramsey interrogation acquires a dependence on the microwave pulse area (amplitude times duration) that can be exploited to implement an active stabilization of the microwave field amplitude, in a similar way in which the Ramsey clock signal is used to lock the local oscillator frequency to the atomic reference. This stabilization results in a reduced sensitivity of the clock frequency to microwave amplitude fluctuations that are transferred to the atoms through the cavity-pulling effect. The proposed technique is then effective to improve the clock stability and drift on medium and long term. We demonstrate the method for a vapor-cell clock working with a hot sample of atoms but it can be extended to cold-atom compact clocks.