Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Direct Reconstruction of the Quantum Density Operator via Measurements of Arbitrary Strength

Giulio Foletto

Published Sep 1, 2017• 0 citations
OpenAlex

Abstract

One of the fundamental problems of experimental quantum physics is the determination of the state of a system, which provides its accurate description and contains all the available information about it. The standard solution is quantum state tomography, a technique that employs a large number of measurements of complementary observables to reconstruct a general density operator. Recently, new protocols have been proposed which allow to obtain the matrix elements one by one with fewer and less complicated observations by exploiting so-called weak measurements, that perturb the system less than ideal projections at the cost of being less precise. This thesis presents an evolution of these schemes that eschews the weakness of the measurement, thus gaining in the accuracy of the results and in practical feasibility. We realized an experiment that uses these methods to reconstruct the density operator of the polarization state of light in single photons regime.

Related papers

Direct Reconstruction of the Quantum Density Matrix by Strong Measurements

Luca Calderaro, Giulio Foletto, Daniele Dequal +2 more

New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.

arXiv:1803.10703•Physical Review Letters•Dec 7, 2018•56 citations

Direct Measurement of the Density Matrix of a Quantum System

Guillaume Thekkadath, Lambert Giner, Yamn Chalich +3 more

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

arXiv:1604.07917•Physical Review Letters•Sep 12, 2016•153 citations

Mapping Out the State of a Quantum System

Andrew N. Jordan

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction.Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states.The scheme relies on measuring a sequence of three observables, each complementary to the last.The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong.We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix.The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons.This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

Physics•Sep 12, 2016•1 citation

Complete Measurement of Two-Photon Density Matrix by Single-Photon Detection

Salini Rajeev, Mayukh Lahiri

The reconstruction of density matrices from measurement data (quantum state tomography) is the most comprehensive method for assessing the accuracy and performance of quantum devices. Existing methods to reconstruct two-photon density matrices require the detection of both photons unless a priori information is available. Based on the concept of quantum-induced coherence by path identity, we present an approach to quantum state tomography that circumvents the requirement of detecting both photons. We show that an arbitrary two-qubit density matrix, which can contain up to fifteen free parameters, can be fully reconstructed from single-photon measurement data without any postselection and a priori information. In addition to advancing an alternative approach to quantum state measurement problems, our results also have notable practical implications. A practical challenge in quantum state measurement arises from the fact that effective single-photon detectors are not readily accessible for a wide spectral range. Our method, which eliminates the need for coincidence measurements, enables quantum state tomography in the case where one of the two photons is challenging or impossible to detect. It therefore opens the door to measuring quantum states hitherto inaccessible.

arXiv:2503.07999•Mar 11, 2025•1 citation

Efficient Direct Measurement of Arbitrary Quantum Systems via Weak Measurement

Changliang Ren, Ya Wang, Jiangfeng Du

Efficient, reliable determination of a system's state is at the heart of quantum science. Directly measuring any desired density-matrix elements is a unique challenge for both theorists and experimentalists, as standard methods have always suffered from the rapid increase in complexity of measurements and reconstruction algorithms. This study presents an efficient scheme for directly measuring arbitrary density matrices with only one strong measurement, or a weak measurement, of each qudit. This method is important for characterizing large-scale quantum systems, and the technology that will be derived from it will be easy to expand and integrate, for example, on a quantum chip.

Physical Review Applied•Jul 24, 2019•14 citations

Direct Characterization of Quantum Measurements Using Weak Values

Liang Xu, Huichao Xu, Tao Jiang +5 more

The time-symmetric formalism endows the weak measurement and its outcome, the weak value, with many unique features. In particular, it allows a direct tomography of quantum states without resorting to complicated reconstruction algorithms and provides an operational meaning to wave functions and density matrices. Here, we propose and experimentally demonstrate the direct tomography of a measurement apparatus by taking the backward direction of weak measurement formalism. Our protocol works rigorously with the arbitrary measurement strength, which offers improved accuracy and precision. The precision can be further improved by taking into account the completeness condition of the measurement operators, which also ensures the feasibility of our protocol for the characterization of the arbitrary quantum measurement. Our work provides new insight on the symmetry between quantum states and measurements, as well as an efficient method to characterize a measurement apparatus.

arXiv:2005.10423•Physical Review Letters•Oct 28, 2021•22 citations
One of the fundamental problems of experimental quantum physics is the determination of the state of a system, which provides its accurate description and contains all the available information about it. The standard solution is quantum state tomography, a technique that employs a large number of measurements of complementary observables to reconstruct a general density operator. Recently, new protocols have been proposed which allow to obtain the matrix elements one by one with fewer and less complicated observations by exploiting so-called weak measurements, that perturb the system less than ideal projections at the cost of being less precise.
This thesis presents an evolution of these schemes that eschews the weakness of the measurement, thus gaining in the accuracy of the results and in practical feasibility. We realized an experiment that uses these methods to reconstruct the density operator of the polarization state of light in single photons regime.
New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction.Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states.The scheme relies on measuring a sequence of three observables, each complementary to the last.The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong.We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix.The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons.This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
The reconstruction of density matrices from measurement data (quantum state tomography) is the most comprehensive method for assessing the accuracy and performance of quantum devices. Existing methods to reconstruct two-photon density matrices require the detection of both photons unless a priori information is available. Based on the concept of quantum-induced coherence by path identity, we present an approach to quantum state tomography that circumvents the requirement of detecting both photons. We show that an arbitrary two-qubit density matrix, which can contain up to fifteen free parameters, can be fully reconstructed from single-photon measurement data without any postselection and a priori information. In addition to advancing an alternative approach to quantum state measurement problems, our results also have notable practical implications. A practical challenge in quantum state measurement arises from the fact that effective single-photon detectors are not readily accessible for a wide spectral range. Our method, which eliminates the need for coincidence measurements, enables quantum state tomography in the case where one of the two photons is challenging or impossible to detect. It therefore opens the door to measuring quantum states hitherto inaccessible.
Efficient, reliable determination of a system's state is at the heart of quantum science. Directly measuring any desired density-matrix elements is a unique challenge for both theorists and experimentalists, as standard methods have always suffered from the rapid increase in complexity of measurements and reconstruction algorithms. This study presents an efficient scheme for directly measuring arbitrary density matrices with only one strong measurement, or a weak measurement, of each qudit. This method is important for characterizing large-scale quantum systems, and the technology that will be derived from it will be easy to expand and integrate, for example, on a quantum chip.
The time-symmetric formalism endows the weak measurement and its outcome, the weak value, with many unique features. In particular, it allows a direct tomography of quantum states without resorting to complicated reconstruction algorithms and provides an operational meaning to wave functions and density matrices. Here, we propose and experimentally demonstrate the direct tomography of a measurement apparatus by taking the backward direction of weak measurement formalism. Our protocol works rigorously with the arbitrary measurement strength, which offers improved accuracy and precision. The precision can be further improved by taking into account the completeness condition of the measurement operators, which also ensures the feasibility of our protocol for the characterization of the arbitrary quantum measurement. Our work provides new insight on the symmetry between quantum states and measurements, as well as an efficient method to characterize a measurement apparatus.