Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1604.07917 · Physical Review Letters

Direct Measurement of the Density Matrix of a Quantum System

Guillaume Thekkadath, Lambert Giner, Yamn Chalich, Matthew J. Horton, Jash Banker, Jeff S. Lundeen

Published Sep 12, 2016• 153 citations
arXivHTMLPDF

Abstract

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

DOI
10.1103/physrevlett.117.120401

Related papers

Mapping Out the State of a Quantum System

Andrew N. Jordan

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction.Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states.The scheme relies on measuring a sequence of three observables, each complementary to the last.The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong.We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix.The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons.This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

Physics•Sep 12, 2016•1 citation

Direct Reconstruction of the Quantum Density Operator via Measurements of Arbitrary Strength

Giulio Foletto

One of the fundamental problems of experimental quantum physics is the determination of the state of a system, which provides its accurate description and contains all the available information about it. The standard solution is quantum state tomography, a technique that employs a large number of measurements of complementary observables to reconstruct a general density operator. Recently, new protocols have been proposed which allow to obtain the matrix elements one by one with fewer and less complicated observations by exploiting so-called weak measurements, that perturb the system less than ideal projections at the cost of being less precise. This thesis presents an evolution of these schemes that eschews the weakness of the measurement, thus gaining in the accuracy of the results and in practical feasibility. We realized an experiment that uses these methods to reconstruct the density operator of the polarization state of light in single photons regime.

•Sep 1, 2017•0 citations

Direct Reconstruction of the Quantum Density Matrix by Strong Measurements

Luca Calderaro, Giulio Foletto, Daniele Dequal +2 more

New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.

arXiv:1803.10703•Physical Review Letters•Dec 7, 2018•56 citations

Directly Measuring the Density Matrix Using Weak Measurements

Guillaume Thekkadath, Lambert Giner, Yamn Chalich +3 more

We demonstrate a method to measure any chosen density matrix element of a quantum system. We determine a photon’s mixed or pure polarization state by sequentially weakly measuring three observables, each complimentary to the last.

Frontiers in Optics•Jan 1, 2016•0 citations

State tomography via weak measurements

Shengjun Wu

Recent work has revealed that the wave function of a pure state can be measured directly and that complementary knowledge of a quantum system can be obtained simultaneously by weak measurements. However, the original scheme applies only to pure states, and it is not efficient because most of the data are discarded by post-selection. Here, we propose tomography schemes for pure states and for mixed states via weak measurements, and our schemes are more efficient because we do not discard any data. Furthermore, we demonstrate that any matrix element of a general state can be directly read from an appropriate weak measurement. The density matrix (with all of its elements) represents all that is directly accessible from a general measurement.

arXiv:1212.3655•Scientific Reports•Feb 1, 2013•96 citations

Direct measurement of density-matrix elements using a phase-shifting technique

Tianfeng Feng, Changliang Ren, Xiaoqi Zhou

A direct measurement protocol allows reconstructing specific elements of the density matrix of a quantum state without using quantum state tomography. However, the direct measurement protocols to date are primarily based on weak or strong measurements with an ancillary pointer, which interacts with the investigated system to extract information about the specified elements. Here, we present a direct measurement scheme based on phase-shifting operations which do not need ancillary pointers. In this method, estimates of at most six expectation values of projective observables suffice to determine any specific element of an unknown quantum density matrix. A concrete quantum circuit to implement this direct measurement protocol for multiqubit states is provided, which is composed of just single-qubit gates and two multiqubit controlled-phase gates. This scheme is also extended for the direct measurement of the density matrix of continuous-variable quantum states. Our method can be used in quantum information applications where only partial information about the quantum state needs to be extracted, for example, problems such as entanglement witnessing, fidelity estimation of quantum systems, and quantum coherence estimation.

arXiv:2101.05556•Physical Review A•Oct 4, 2021•7 citations
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction.Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states.The scheme relies on measuring a sequence of three observables, each complementary to the last.The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong.We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix.The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons.This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
One of the fundamental problems of experimental quantum physics is the determination of the state of a system, which provides its accurate description and contains all the available information about it. The standard solution is quantum state tomography, a technique that employs a large number of measurements of complementary observables to reconstruct a general density operator. Recently, new protocols have been proposed which allow to obtain the matrix elements one by one with fewer and less complicated observations by exploiting so-called weak measurements, that perturb the system less than ideal projections at the cost of being less precise. This thesis presents an evolution of these schemes that eschews the weakness of the measurement, thus gaining in the accuracy of the results and in practical feasibility. We realized an experiment that uses these methods to reconstruct the density operator of the polarization state of light in single photons regime.
New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.
Recent work has revealed that the wave function of a pure state can be measured directly and that complementary knowledge of a quantum system can be obtained simultaneously by weak measurements. However, the original scheme applies only to pure states, and it is not efficient because most of the data are discarded by post-selection. Here, we propose tomography schemes for pure states and for mixed states via weak measurements, and our schemes are more efficient because we do not discard any data. Furthermore, we demonstrate that any matrix element of a general state can be directly read from an appropriate weak measurement. The density matrix (with all of its elements) represents all that is directly accessible from a general measurement.
A direct measurement protocol allows reconstructing specific elements of the density matrix of a quantum state without using quantum state tomography. However, the direct measurement protocols to date are primarily based on weak or strong measurements with an ancillary pointer, which interacts with the investigated system to extract information about the specified elements. Here, we present a direct measurement scheme based on phase-shifting operations which do not need ancillary pointers. In this method, estimates of at most six expectation values of projective observables suffice to determine any specific element of an unknown quantum density matrix. A concrete quantum circuit to implement this direct measurement protocol for multiqubit states is provided, which is composed of just single-qubit gates and two multiqubit controlled-phase gates. This scheme is also extended for the direct measurement of the density matrix of continuous-variable quantum states. Our method can be used in quantum information applications where only partial information about the quantum state needs to be extracted, for example, problems such as entanglement witnessing, fidelity estimation of quantum systems, and quantum coherence estimation.