Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1212.3655 · Scientific Reports

State tomography via weak measurements

Shengjun Wu

Published Feb 1, 2013• 96 citations
arXivHTMLPDF

Abstract

Recent work has revealed that the wave function of a pure state can be measured directly and that complementary knowledge of a quantum system can be obtained simultaneously by weak measurements. However, the original scheme applies only to pure states, and it is not efficient because most of the data are discarded by post-selection. Here, we propose tomography schemes for pure states and for mixed states via weak measurements, and our schemes are more efficient because we do not discard any data. Furthermore, we demonstrate that any matrix element of a general state can be directly read from an appropriate weak measurement. The density matrix (with all of its elements) represents all that is directly accessible from a general measurement.

DOI
10.1038/srep01193

Related papers

Weak Measurements Compressed Sensing Quantum State Tomography

Dikla Oren, Yonina C. Eldar, Mordechai Segev

We show that prior knowledge that a quantum state is close to a pure state enables a direct and efficient measurement of the density matrix representing the state, using the weak measurements methodology.

Conference on Lasers and Electro-Optics•Jan 1, 2016•1 citation

Direct Measurement of the Density Matrix of a Quantum System

Guillaume Thekkadath, Lambert Giner, Yamn Chalich +3 more

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

arXiv:1604.07917•Physical Review Letters•Sep 12, 2016•153 citations

Direct Reconstruction of the Quantum Density Matrix by Strong Measurements

Luca Calderaro, Giulio Foletto, Daniele Dequal +2 more

New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.

arXiv:1803.10703•Physical Review Letters•Dec 7, 2018•56 citations

Procedure for Direct Measurement of General Quantum States Using Weak Measurement

Jeff S. Lundeen, C. Bamber

Recent work by Lundeen et al. [Nature (London) 474, 188 (2011)] directly measured the wave function by weakly measuring a variable followed by a normal (i.e., "strong") measurement of the complementary variable. We generalize this method to mixed states by considering the weak measurement of various products of these observables, thereby providing the density matrix an operational definition in terms of a procedure for its direct measurement. The method only requires measurements in two bases and can be performed in situ, determining the quantum state without destroying it.

arXiv:1112.5471•Physical Review Letters•Feb 13, 2012•309 citations

Mapping Out the State of a Quantum System

Andrew N. Jordan

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction.Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states.The scheme relies on measuring a sequence of three observables, each complementary to the last.The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong.We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix.The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons.This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

Physics•Sep 12, 2016•1 citation

Direct measurement of nonlocal quantum states without approximation

Gang 冈 Yang 杨, Ran 然 Yang 杨, Yan-Xiao Gong +1 more

Efficient acquiring information from a quantum state is important for research in fundamental quantum physics and quantum information applications. Instead of using standard quantum state tomography method with reconstruction algorithm, weak values were proposed to directly measure density matrix elements of quantum state. Recently, similar to the concept of weak value, modular values were introduced to extend the direct measurement scheme to nonlocal quantum wavefunction. However, this method still involves approximations, which leads to inherent low precision. Here, we propose a new scheme which enables direct measurement for ideal value of the nonlocal density matrix element without taking approximations. Our scheme allows more accurate characterization of nonlocal quantum states, and therefore has greater advantages in practical measurement scenarios.

Chinese Physics B•Sep 1, 2023•3 citations
Recent work has revealed that the wave function of a pure state can be measured directly and that complementary knowledge of a quantum system can be obtained simultaneously by weak measurements. However, the original scheme applies only to pure states, and it is not efficient because most of the data are discarded by post-selection. Here, we propose tomography schemes for pure states and for mixed states via weak measurements, and our schemes are more efficient because we do not discard any data. Furthermore, we demonstrate that any matrix element of a general state can be directly read from an appropriate weak measurement. The density matrix (with all of its elements) represents all that is directly accessible from a general measurement.
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.
Recent work by Lundeen et al. [Nature (London) 474, 188 (2011)] directly measured the wave function by weakly measuring a variable followed by a normal (i.e., "strong") measurement of the complementary variable. We generalize this method to mixed states by considering the weak measurement of various products of these observables, thereby providing the density matrix an operational definition in terms of a procedure for its direct measurement. The method only requires measurements in two bases and can be performed in situ, determining the quantum state without destroying it.
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction.Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states.The scheme relies on measuring a sequence of three observables, each complementary to the last.The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong.We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix.The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons.This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
Efficient acquiring information from a quantum state is important for research in fundamental quantum physics and quantum information applications. Instead of using standard quantum state tomography method with reconstruction algorithm, weak values were proposed to directly measure density matrix elements of quantum state. Recently, similar to the concept of weak value, modular values were introduced to extend the direct measurement scheme to nonlocal quantum wavefunction. However, this method still involves approximations, which leads to inherent low precision. Here, we propose a new scheme which enables direct measurement for ideal value of the nonlocal density matrix element without taking approximations. Our scheme allows more accurate characterization of nonlocal quantum states, and therefore has greater advantages in practical measurement scenarios.