arXiv:1112.5471 · Physical Review Letters

Procedure for Direct Measurement of General Quantum States Using Weak Measurement

Jeff S. Lundeen, C. Bamber

Published Feb 13, 2012• 309 citations
arXivHTMLPDF

Abstract

Recent work by Lundeen et al. [Nature (London) 474, 188 (2011)] directly measured the wave function by weakly measuring a variable followed by a normal (i.e., "strong") measurement of the complementary variable. We generalize this method to mixed states by considering the weak measurement of various products of these observables, thereby providing the density matrix an operational definition in terms of a procedure for its direct measurement. The method only requires measurements in two bases and can be performed in situ, determining the quantum state without destroying it.

DOI
10.1103/physrevlett.108.070402

Related papers

Weak measurement of the Dirac distribution

Jeff S. Lundeen, C. Bamber

Recent work [J.S. Lundeen et al. Nature, 474, 188 (2011)] directly measured the wavefunction by weakly measuring a variable followed by a normal (i.e. `strong') measurement of the complementary variable. We generalize this method to mixed states by considering the weak measurement of the product of the two observables, which, as a non-Hermitian operator, is normally unobservable. This generalized method provides mixed states an operational definition related to the operator representation proposed by Dirac. Uniquely, it can be performed `in situ', determing the quantum state without destroying it.

arXiv:1110.0727•Oct 4, 2011•3 citations

Strong Measurements Give a Better Direct Measurement of the Quantum Wave Function

Giuseppe Vallone, Daniele Dequal

Weak measurements have thus far been considered instrumental in the so-called direct measurement of the quantum wave function [4J. S. Lundeen, Nature (London) 474, 188 (2011).]. Here we show that a direct measurement of the wave function can be obtained by using measurements of arbitrary strength. In particular, in the case of strong measurements, i.e., those in which the coupling between the system and the measuring apparatus is maximum, we compared the precision and the accuracy of the two methods, by showing that strong measurements outperform weak measurements in both for arbitrary quantum states in most cases. We also give the exact expression of the difference between the original and reconstructed wave function obtained by the weak measurement approach; this will allow one to define the range of applicability of such a method.

arXiv:1504.06551•Physical Review Letters•Jan 29, 2016•98 citations

State tomography via weak measurements

Shengjun Wu

Recent work has revealed that the wave function of a pure state can be measured directly and that complementary knowledge of a quantum system can be obtained simultaneously by weak measurements. However, the original scheme applies only to pure states, and it is not efficient because most of the data are discarded by post-selection. Here, we propose tomography schemes for pure states and for mixed states via weak measurements, and our schemes are more efficient because we do not discard any data. Furthermore, we demonstrate that any matrix element of a general state can be directly read from an appropriate weak measurement. The density matrix (with all of its elements) represents all that is directly accessible from a general measurement.

arXiv:1212.3655•Scientific Reports•Feb 1, 2013•96 citations

Direct Measurement of the Density Matrix of a Quantum System

Guillaume Thekkadath, Lambert Giner, Yamn Chalich +3 more

One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

arXiv:1604.07917•Physical Review Letters•Sep 12, 2016•153 citations

Directly Measuring the Density Matrix Using Weak Measurements

Guillaume Thekkadath, Lambert Giner, Yamn Chalich +3 more

We demonstrate a method to measure any chosen density matrix element of a quantum system. We determine a photon’s mixed or pure polarization state by sequentially weakly measuring three observables, each complimentary to the last.

Frontiers in Optics•Jan 1, 2016•0 citations

Direct Reconstruction of the Quantum Density Matrix by Strong Measurements

Luca Calderaro, Giulio Foletto, Daniele Dequal +2 more

New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.

arXiv:1803.10703•Physical Review Letters•Dec 7, 2018•56 citations
Recent work by Lundeen et al. [Nature (London) 474, 188 (2011)] directly measured the wave function by weakly measuring a variable followed by a normal (i.e., "strong") measurement of the complementary variable. We generalize this method to mixed states by considering the weak measurement of various products of these observables, thereby providing the density matrix an operational definition in terms of a procedure for its direct measurement. The method only requires measurements in two bases and can be performed in situ, determining the quantum state without destroying it.
Recent work [J.S. Lundeen et al. Nature, 474, 188 (2011)] directly measured the wavefunction by weakly measuring a variable followed by a normal (i.e. `strong') measurement of the complementary variable. We generalize this method to mixed states by considering the weak measurement of the product of the two observables, which, as a non-Hermitian operator, is normally unobservable. This generalized method provides mixed states an operational definition related to the operator representation proposed by Dirac. Uniquely, it can be performed `in situ', determing the quantum state without destroying it.
Weak measurements have thus far been considered instrumental in the so-called direct measurement of the quantum wave function [4J. S. Lundeen, Nature (London) 474, 188 (2011).]. Here we show that a direct measurement of the wave function can be obtained by using measurements of arbitrary strength. In particular, in the case of strong measurements, i.e., those in which the coupling between the system and the measuring apparatus is maximum, we compared the precision and the accuracy of the two methods, by showing that strong measurements outperform weak measurements in both for arbitrary quantum states in most cases. We also give the exact expression of the difference between the original and reconstructed wave function obtained by the weak measurement approach; this will allow one to define the range of applicability of such a method.
Recent work has revealed that the wave function of a pure state can be measured directly and that complementary knowledge of a quantum system can be obtained simultaneously by weak measurements. However, the original scheme applies only to pure states, and it is not efficient because most of the data are discarded by post-selection. Here, we propose tomography schemes for pure states and for mixed states via weak measurements, and our schemes are more efficient because we do not discard any data. Furthermore, we demonstrate that any matrix element of a general state can be directly read from an appropriate weak measurement. The density matrix (with all of its elements) represents all that is directly accessible from a general measurement.
One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.
New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.