Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Design of active all-optical magnetometer

Duo Pan, Tiantian Shi, Xiang Peng, Jingbiao Chen, Hong Mei Guo

Published Jul 1, 2017• 0 citations
Publisher

Abstract

We propose an active all-optical magnetometer based on Cesium four-level atomic system. The magnetometer is free of radio frequency antenna, thus has smaller measure volumes. With an theoretical milli Hertz linewidth of the four-level active optical clock, the magnetometer has a potential sensitivity of tens of fT Hz-1/2.
DOI
10.1109/fcs.2017.8088876

Related papers

The impact of radio-frequency magnetic field on atomic magnetometer

Yang-Ying Fu, Jie Yuan

The impact of radio-frequency magnetic field on the cesium atomic magnetometer is investigated. A theoretical model based on Bloch equation is provided, which predicts the properties of magnetometer. A cesium atomic magnetometer is designed for the experimental measurements. The magnetometer linewidth and sensitivity, as a function of radio-frequency magnetic field size are obtained. The experimental results are in agreement with what predicted by the theoretical model. The results, both theoretical and experimental included, indicate that there is an optimal radio-frequency magnetic field size, at which value the magnetometer sensitivity is highest. This work enlightens the parameter optimization of atomic magnetometer, and helps for the enhancement of magnetometer sensitivity.

Tenth International Conference on Information Optics and Photonics•Dec 20, 2019•0 citations

Realization and Optimization of all-optical Cs atom magnetometer based on Bell-Bloom structure

Zhang Jun-ha

In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.

Journal of Optoelectronics·laser•Jan 1, 2015•0 citations

All-Optical Vector Cesium Magnetometer

Weimin Sun, Qiang Huang, Zongjun Huang +2 more

Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.

Chinese Physics Letters•May 1, 2017•12 citations

Cesium based laser-atomic oscillator

Saurabh Pandey, Roger Ding, George R. Burns +1 more

We report the first demonstration of a laser-atomic oscillator with cesium (Cs) atoms. A laser-atomic oscillator is analogous to an active mode-locked laser with a self-excited modulator, i.e., atoms, at a ground-state hyperfine transition frequency. Therefore, a laser-atomic oscillator can be configured as the simplest active atomic clock or a self-oscillating, earth-field atomic magnetometer that delivers oscillation signals both optically and electrically. With the current experimental Cs laser-atomic oscillator (Cs-LAO) setup, when it is configured as an atomic clock using the 0–0 hyperfine transition, the short-term fractional frequency instability is around the 10−10 level. When it is configured as a self-oscillating magnetometer using a magnetically sensitive 3–3 hyperfine transition, the magnetic field sensitivity is around 100 fT/Hz at 60 Hz. The presented Cs-LAO uses a cavity length from ∼6.5 to ∼11.4 cm. Ultimately, the minimal length of a Cs-LAO device can be ≤1.63 cm. Our new efforts unlock the potential of building truly chip-scale atomic clocks and magnetometers.

arXiv:2606.32019•Applied Physics Letters•Oct 26, 2026•0 citations

All-optical vector atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

Bulletin of the American Physical Society•Jun 5, 2014•21 citations

Miniaturized atomic magnetometer employing pump-beam modulation

Ziqian Yue, Junjian Tang, Yueyang Zhai

Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).

Advanced Sensor Systems and Applications•Oct 11, 2024•0 citations
The impact of radio-frequency magnetic field on the cesium atomic magnetometer is investigated. A theoretical model based on Bloch equation is provided, which predicts the properties of magnetometer. A cesium atomic magnetometer is designed for the experimental measurements. The magnetometer linewidth and sensitivity, as a function of radio-frequency magnetic field size are obtained. The experimental results are in agreement with what predicted by the theoretical model. The results, both theoretical and experimental included, indicate that there is an optimal radio-frequency magnetic field size, at which value the magnetometer sensitivity is highest. This work enlightens the parameter optimization of atomic magnetometer, and helps for the enhancement of magnetometer sensitivity.
In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.
Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.
We report the first demonstration of a laser-atomic oscillator with cesium (Cs) atoms. A laser-atomic oscillator is analogous to an active mode-locked laser with a self-excited modulator, i.e., atoms, at a ground-state hyperfine transition frequency. Therefore, a laser-atomic oscillator can be configured as the simplest active atomic clock or a self-oscillating, earth-field atomic magnetometer that delivers oscillation signals both optically and electrically. With the current experimental Cs laser-atomic oscillator (Cs-LAO) setup, when it is configured as an atomic clock using the 0–0 hyperfine transition, the short-term fractional frequency instability is around the 10−10 level. When it is configured as a self-oscillating magnetometer using a magnetically sensitive 3–3 hyperfine transition, the magnetic field sensitivity is around 100 fT/Hz at 60 Hz. The presented Cs-LAO uses a cavity length from ∼6.5 to ∼11.4 cm. Ultimately, the minimal length of a Cs-LAO device can be ≤1.63 cm. Our new efforts unlock the potential of building truly chip-scale atomic clocks and magnetometers.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).