Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Radiative lifetime of metastable Xe3+ measured using an electrostatic ion beam trap

M. Saito, Asahi Chikaoka, T. Majima, Makoto Imai, H. Tsuchida

Published Jul 1, 2017• 0 citations
Publisher

Abstract

We have measured the radiative lifetime of the 2 P 3/2 metastable level in Xe 3+ using an electrostatic ion beam trap. The lifetime was obtained by measuring the number of photons emitted during the 2 P 3/2 → 2 D 3/2 transition of Xe 3+ as a function of the storage time. The lifetime is compared with previously reported theoretical and experimental values.

DOI
10.1088/1742-6596/875/3/022048

Related papers

Radiative lifetime of the metastable 1S0 state of Xe2+

K. G. Bhushan, Henrik B. Pedersen, N. Altstein +3 more

The radiative lifetime of the ${}^{1}{S}_{0}$ metastable state of ${\mathrm{Xe}}^{2+}$ has been measured with a different type of electrostatic ion trap. The ion trap stores ion beams of a few keV using purely electrostatic fields and provides a large field-free region where the stored ions oscillate. A photomultiplier working in the single-photon counting mode was used to observe the 380 nm photons arising from the magnetic dipole $(M1)$ transition ${}^{1}{\stackrel{\ensuremath{\rightarrow}}{{S}_{0}}}^{3}{P}_{1}$ of ${\mathrm{Xe}}^{2+}.$ The present measurement yields a value of $4.46\ifmmode\pm\else\textpm\fi{}0.08 \mathrm{ms},$ which is in good agreement with previous measurements, but is almost four times more accurate.

Physical Review A•Jun 8, 2000•30 citations

Radiative lifetime measurement of the1S0metastable state of Kr2+using an electrostatic ion trap

Suguru Itoi, Hiroaki Kai, M. Saito +1 more

We measured the radiative lifetime of the 1S0 metastable state of Kr2+. This state dominantly decays to the 3P1 state via a magnetic dipole transition. The lifetime was determined by measuring emitted photons (350.5 nm) as a result of the 1S0 → 3P1 decay of Kr2+ stored in an electrostatic ion trap. The obtained radiative lifetime was 15.3 ± 0.9 ms, which agrees with the experimental value reported by Calamai and Johnson (1992 Phys. Rev. A 45 7792) within experimental error.

Physica Scripta•Sep 1, 2013•3 citations

Lifetime measurement of He− using an electrostatic ion trap

Alex Wolf, K. G. Bhushan, I. Ben-Itzhak +4 more

The lifetimes of the metastable $1s2s2p{ }^{4}{P}_{5/2}$ level of ${\mathrm{He}}^{\ensuremath{-}},$ as well as the lifetime of the average of the ${}^{4}{P}_{3/2}$ and ${}^{4}{P}_{1/2}$ levels, have been measured using a new type of ion trap that stores keV ion beams using electrostatic fields only. The use of a pure electrostatic field avoids the complication of magnetic-field-induced mixing effects, which can interfere with the measurement of the spontaneous decay. The measured lifetime for the ${}^{4}{P}_{5/2}$ state, after correction for decay induced by blackbody radiation, is $343\ifmmode\pm\else\textpm\fi{}10 \ensuremath{\mu}\mathrm{s}.$ This value is consistent with previous experiments, and in excellent agreement with the most recent theoretical calculations. The average lifetime of the ${}^{4}{P}_{3/2}$ and ${}^{4}{P}_{1/2}$ is $8.9\ifmmode\pm\else\textpm\fi{}0.2 \ensuremath{\mu}\mathrm{s},$ which is about 20% lower than the weighted theoretical value.

Physical Review A•Jan 1, 1999•56 citations

Lifetime of the XeII6p4P5/20level using the fast-beam-laser method

R. E. Silverans, G. Borghs, Peter De Bisschop +2 more

The lifetime of the Xe II 5p 4 6p 4 P 5/2 0 level is measured by selective laser excitation of a fast beam of metastable 5p 4 5d 4 D 7/2 xenon ions and observations of the fluorescent light intensity as a function of flight time. Comparison of the obtained mean lifetime tau =7.53+or-0.15 ns with earlier measurements confirms the results of the photon-photon delayed-coincidence technique.

Journal of Physics B Atomic and Molecular Physics•Jan 28, 1981•10 citations

Radiative lifetime of metastable 2S13 Li+

Randall D. Knight, Michael H. Prior

The radiative lifetime of $1s2s^{3}S_{1}$ ${\mathrm{Li}}^{+}$ ions has been measured by a comparison of the count rate of spontaneous decay photons (210 \AA{}) to a laser-induced fluorescence signal proportional to the total number of metastable ions. The ions were confined in a rf-quadrupole trap, and the fluorescence signal used was the intercombination transition $1s2p^{3}P_{1}$ to $1{s}^{2}^{1}S_{0}$ at 202 \AA{}. The $^{3}P_{1}$ state was populated from $^{3}S_{1}$ by absorption of laser photons at 5485 \AA{}. The result is ${\ensuremath{\tau}}_{r}=58.6\ifmmode\pm\else\textpm\fi{}12.9$ sec (95% confidence level); theory predicts ${\ensuremath{\tau}}_{r}=49.1$ sec.

Physical Review A•Jan 1, 1980•50 citations

Radiative Lifetime of Metastable Li II 2S01

Michael H. Prior, Howard A. Shugart

The radiative lifetime of Li II $2^{1}S_{0}$ has been measured by counting decay photons versus time from an ensemble of metastable Li ions stored in a simple electromagnetic trap of the Penning variety. The result is ${\ensuremath{\tau}}_{\mathrm{expt}}=503(26)$ \ensuremath{\mu}sec. The error represents one standard deviation from the mean of a series of 34 separate determinations. This result is in agreement with the theoretical value ${\ensuremath{\tau}}_{\mathrm{th}}=513$ \ensuremath{\mu}sec.

Physical Review Letters•Oct 4, 1971•46 citations
We have measured the radiative lifetime of the 2 P 3/2 metastable level in Xe 3+ using an electrostatic ion beam trap. The lifetime was obtained by measuring the number of photons emitted during the 2 P 3/2 → 2 D 3/2 transition of Xe 3+ as a function of the storage time. The lifetime is compared with previously reported theoretical and experimental values.
The radiative lifetime of the 1S0{}^{1}{S}_{0}1S0​ metastable state of Xe2+{\mathrm{Xe}}^{2+}Xe2+ has been measured with a different type of electrostatic ion trap. The ion trap stores ion beams of a few keV using purely electrostatic fields and provides a large field-free region where the stored ions oscillate. A photomultiplier working in the single-photon counting mode was used to observe the 380 nm photons arising from the magnetic dipole (M1)(M1)(M1) transition ${}^{1}{\stackrel{\ensuremath{\rightarrow}}{{S}_{0}}}^{3}{P}_{1}$ of Xe2+.{\mathrm{Xe}}^{2+}.Xe2+. The present measurement yields a value of $4.46\ifmmode\pm\else\textpm\fi{}0.08 \mathrm{ms},$ which is in good agreement with previous measurements, but is almost four times more accurate.
The lifetimes of the metastable 1s2s2p4P5/21s2s2p{ }^{4}{P}_{5/2}1s2s2p4P5/2​ level of ${\mathrm{He}}^{\ensuremath{-}},$ as well as the lifetime of the average of the 4P3/2{}^{4}{P}_{3/2}4P3/2​ and 4P1/2{}^{4}{P}_{1/2}4P1/2​ levels, have been measured using a new type of ion trap that stores keV ion beams using electrostatic fields only. The use of a pure electrostatic field avoids the complication of magnetic-field-induced mixing effects, which can interfere with the measurement of the spontaneous decay. The measured lifetime for the 4P5/2{}^{4}{P}_{5/2}4P5/2​ state, after correction for decay induced by blackbody radiation, is $343\ifmmode\pm\else\textpm\fi{}10 \ensuremath{\mu}\mathrm{s}.$ This value is consistent with previous experiments, and in excellent agreement with the most recent theoretical calculations. The average lifetime of the 4P3/2{}^{4}{P}_{3/2}4P3/2​ and 4P1/2{}^{4}{P}_{1/2}4P1/2​ is $8.9\ifmmode\pm\else\textpm\fi{}0.2 \ensuremath{\mu}\mathrm{s},$ which is about 20% lower than the weighted theoretical value.
The radiative lifetime of 1s2s3S11s2s^{3}S_{1}1s2s3S1​ Li+{\mathrm{Li}}^{+}Li+ ions has been measured by a comparison of the count rate of spontaneous decay photons (210 \AA{}) to a laser-induced fluorescence signal proportional to the total number of metastable ions. The ions were confined in a rf-quadrupole trap, and the fluorescence signal used was the intercombination transition 1s2p3P11s2p^{3}P_{1}1s2p3P1​ to $1{s}^{2}^{1}S_{0}$ at 202 \AA{}. The 3P1^{3}P_{1}3P1​ state was populated from 3S1^{3}S_{1}3S1​ by absorption of laser photons at 5485 \AA{}. The result is ${\ensuremath{\tau}}_{r}=58.6\ifmmode\pm\else\textpm\fi{}12.9$ sec (95% confidence level); theory predicts ${\ensuremath{\tau}}_{r}=49.1$ sec.
The radiative lifetime of Li II 21S02^{1}S_{0}21S0​ has been measured by counting decay photons versus time from an ensemble of metastable Li ions stored in a simple electromagnetic trap of the Penning variety. The result is ${\ensuremath{\tau}}_{\mathrm{expt}}=503(26)$ \ensuremath{\mu}sec. The error represents one standard deviation from the mean of a series of 34 separate determinations. This result is in agreement with the theoretical value ${\ensuremath{\tau}}_{\mathrm{th}}=513$ \ensuremath{\mu}sec.