Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Quantum Theory of Superresolution for Incoherent Optical Imaging

Mankei Tsang

Published Mar 17, 2017• 0 citations
OpenAlex

Related papers

Quantum limit of superresolution with a noisy imaging system

Changhun Oh, Sisi Zhou, Yat Wong +1 more

Bulletin of the American Physical Society•Mar 16, 2021•0 citations

Quantum Theory of Superresolution for Two Incoherent Optical Point Sources

Mankei Tsang, Ranjith Nair, Xiao-Ming Lu

Rayleigh's criterion for resolving two incoherent point sources has been the most influential measure of optical imaging resolution for over a century.In the context of statistical image processing, violation of the criterion is especially detrimental to the estimation of the separation between the sources, and modern far-field superresolution techniques rely on suppressing the emission of close sources to enhance the localization precision.Using quantum optics, quantum metrology, and statistical analysis, here we show that, even if two close incoherent sources emit simultaneously, measurements with linear optics and photon counting can estimate their separation from the far field almost as precisely as conventional methods do for isolated sources, rendering Rayleigh's criterion irrelevant to the problem.Our results demonstrate that superresolution can be achieved not only for fluorophores but also for stars.

arXiv:1511.00552•Physical Review X•Aug 29, 2016•474 citations

Optimal quantum superresolution for full distance between incoherent optical sources in two dimensions

Junyan Li, Shengshi Pang

The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.

arXiv:2508.08049•Physical Review A•Feb 12, 2026•0 citations

Quantum Theory of Three-Dimensional Superresolution Using Rotating-PSF Imagery

Sudhakar Prasad, Ziheng Yu

Advanced Maui Optical and Space Surveillance Technologies Conference•Jan 1, 2017•1 citation

Superresolution imaging of two incoherent optical sources with unequal brightnesses

Jiandong Zhang, Yiwen Fu, Lili Hou +1 more

Resolving the separation between two incoherent optical sources with high precision is of great significance for fluorescence imaging and astronomical observations. In this paper, we focus on a more general scenario where two sources have unequal brightnesses. We give the ultimate precision limit with respect to separation by using the quantum Fisher information. Through the calculation of the classical Fisher information, we analyze and compare several specific measurement schemes including direct measurement, Gaussian mode measurement and zero-photon measurement. The results indicate that Gaussian mode measurement is the nearly optimal for a small separation. On this basis, the effects of relative brightness fluctuation are addressed. Our work provides a positive complement to the aspect of superresolution imaging of incoherent sources.

arXiv:2404.17463•Optics Express•Jun 27, 2024•9 citations

Quantum Limits of Optical Super-Resolution

Mikhail I. Kolobov

Springer eBooks•Nov 2, 2007•4 citations
Rayleigh's criterion for resolving two incoherent point sources has been the most influential measure of optical imaging resolution for over a century.In the context of statistical image processing, violation of the criterion is especially detrimental to the estimation of the separation between the sources, and modern far-field superresolution techniques rely on suppressing the emission of close sources to enhance the localization precision.Using quantum optics, quantum metrology, and statistical analysis, here we show that, even if two close incoherent sources emit simultaneously, measurements with linear optics and photon counting can estimate their separation from the far field almost as precisely as conventional methods do for isolated sources, rendering Rayleigh's criterion irrelevant to the problem.Our results demonstrate that superresolution can be achieved not only for fluorophores but also for stars.
The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.
Resolving the separation between two incoherent optical sources with high precision is of great significance for fluorescence imaging and astronomical observations. In this paper, we focus on a more general scenario where two sources have unequal brightnesses. We give the ultimate precision limit with respect to separation by using the quantum Fisher information. Through the calculation of the classical Fisher information, we analyze and compare several specific measurement schemes including direct measurement, Gaussian mode measurement and zero-photon measurement. The results indicate that Gaussian mode measurement is the nearly optimal for a small separation. On this basis, the effects of relative brightness fluctuation are addressed. Our work provides a positive complement to the aspect of superresolution imaging of incoherent sources.