Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2404.17463 · Optics Express

Superresolution imaging of two incoherent optical sources with unequal brightnesses

Jiandong Zhang, Yiwen Fu, Lili Hou, Shuai Wang

Published Jun 27, 2024• 9 citations
arXivHTMLPDF

Abstract

Resolving the separation between two incoherent optical sources with high precision is of great significance for fluorescence imaging and astronomical observations. In this paper, we focus on a more general scenario where two sources have unequal brightnesses. We give the ultimate precision limit with respect to separation by using the quantum Fisher information. Through the calculation of the classical Fisher information, we analyze and compare several specific measurement schemes including direct measurement, Gaussian mode measurement and zero-photon measurement. The results indicate that Gaussian mode measurement is the nearly optimal for a small separation. On this basis, the effects of relative brightness fluctuation are addressed. Our work provides a positive complement to the aspect of superresolution imaging of incoherent sources.

DOI
10.1364/oe.528683

Related papers

Quantum limited super-resolution of an unequal-brightness source pair in three dimensions

Sudhakar Prasad

Abstract This paper extends our previous quantum Fisher information (QFI) based analysis of the problem of separating a pair of equal-brightness incoherent point sources in three dimensions to the case of a pair of sources that are unequally bright. When the pair's geometric center is perfectly known in advance, QFI with respect to the estimation of the three separation coordinates remains independent of the degree of brightness asymmetry. For the experimentally more relevant case of perfect prior knowledge of the pair's brightness centroid, however, such QFI becomes dependent on the pair separation vector in a way that is controlled by the degree of its brightness asymmetry. This study yields potentially useful insights into the analysis of a more general superresolution imaging problem involving extended incoherent sources with nontrivial brightness distributions.

arXiv:1908.10949•Physica Scripta•Nov 13, 2019•25 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Multiparameter approach to experimental separation estimation of unequally bright sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque +1 more

Due to the wave nature of light, optical imaging is inherently subject to diffraction, which typically dictates the resolution limit for two-point sources. A practical way to describe this phenomenon is through Rayleigh’s criterion, which states that two sources are barely resolvable when the minimum of one source's diffraction pattern coincides with the maximum of the other. However, recent advances in optical quantum metrology have shown that this classical limit can be surpassed by leveraging the spatial correlations within the light field. Specifically, decomposing the light into a Hermite-Gauss mode basis provides substantially more information than traditional direct imaging, which measures local intensity [1,2,3]. In this work, we implement a spatial demultiplexing technique to estimate the separation between light sources of unequal brightness. This unknown imbalance adds complexity to the estimation task, making it inherently a multiparameter problem and thus requiring a multimode approach [4]. By optimizing the measurement strategy and introducing a shift between two demultiplexers, we achieve sub-Rayleigh resolution in distance measurements without assuming prior knowledge of the intensity imbalance or alignment. [1] Tsang, M., Nair, R., & Lu, X. M. (2016). Quantum theory of superresolution for two incoherent optical point sources. Physical Review X, 6(3), 031033. [2] Sorelli, G., Gessner, M., Walschaers, M., & Treps, N. (2021). Optimal observables and estimators for practical superresolution imaging. Physical Review Letters, 127(12), 123604. [3] Rouvière, C., Barral, D., Grateau, A., Karuseichyk, I., Sorelli, G., Walschaers, M., & Treps, N. (2024). Ultra-sensitive separation estimation of optical sources. Optica, 11(2), 166-170. [4] Řeháček, J., Hradil, Z., Koutný, D., Grover, J., Krzic, A., & Sánchez-Soto, L. L. (2018). Optimal measurements for quantum spatial superresolution. Physical review A, 98(1), 012103.

SPIE Quantum Technologies for Defence and Security•Oct 29, 2025•0 citations

Single-photon sub-Rayleigh precision measurements of a pair of incoherent sources of unequal intensity

Luigi Santamaria Amato, Fabrizio Sgobba, Cosmo Lupo

Interferometric methods have been recently investigated to achieve sub-Rayleigh imaging and precision measurements of faint incoherent sources up to the ultimate quantum limit. Here we consider single-photon imaging of two point-like emitters of unequal intensity. This is motivated by the fact that pairs of natural emitters typically have unequal brightness, for example, binary star systems and exoplanets. We address the problem of estimating the transverse separation d or the relative intensity . Our theoretical analysis shows that the associated statistical errors are qualitatively different from the case of equal intensity. We employ multi-plane light conversion technology to implement Hermite–Gaussian (HG) spatial-mode demultiplexing (SPADE), and demonstrate sub-Rayleigh measurement of two emitters with a Gaussian point-spread function. The experimental errors are comparable with the theoretical bounds. The latter are benchmarked against direct imaging, yielding an improvement in the signal-to-noise ratio, which may be significant when the primary source is much brighter than the secondary one, for example, as for imaging of exoplanets.

arXiv:2309.02295•Optica Quantum•Jan 26, 2024•30 citations

Quantum Limits of Superresolution in a Noisy Environment

Changhun Oh, Sisi Zhou, Yat Wong +1 more

We analyze the ultimate quantum limit of resolving two identical sources in a noisy environment. We prove that in the presence of noise causing false excitation, such as thermal noise, the quantum Fisher information of arbitrary quantum states for the separation of the objects, which quantifies the resolution, always converges to zero as the separation goes to zero. Noisy cases contrast with noiseless cases where the quantum Fisher information has been shown to be nonzero for a small distance in various circumstances, revealing the superresolution. In addition, we show that false excitation on an arbitrary measurement, such as dark counts, also makes the classical Fisher information of the measurement approach to zero as the separation goes to zero. Finally, a practically relevant situation resolving two identical thermal sources is quantitatively investigated by using the quantum and classical Fisher information of finite spatial mode multiplexing, showing that the amount of noise poses a limit on the resolution in a noisy system.

arXiv:2008.11339•Physical Review Letters•Mar 26, 2021•42 citations

Optimal quantum superresolution for full distance between incoherent optical sources in two dimensions

Junyan Li, Shengshi Pang

The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.

arXiv:2508.08049•Physical Review A•Feb 12, 2026•0 citations
Resolving the separation between two incoherent optical sources with high precision is of great significance for fluorescence imaging and astronomical observations. In this paper, we focus on a more general scenario where two sources have unequal brightnesses. We give the ultimate precision limit with respect to separation by using the quantum Fisher information. Through the calculation of the classical Fisher information, we analyze and compare several specific measurement schemes including direct measurement, Gaussian mode measurement and zero-photon measurement. The results indicate that Gaussian mode measurement is the nearly optimal for a small separation. On this basis, the effects of relative brightness fluctuation are addressed. Our work provides a positive complement to the aspect of superresolution imaging of incoherent sources.
Abstract This paper extends our previous quantum Fisher information (QFI) based analysis of the problem of separating a pair of equal-brightness incoherent point sources in three dimensions to the case of a pair of sources that are unequally bright. When the pair's geometric center is perfectly known in advance, QFI with respect to the estimation of the three separation coordinates remains independent of the degree of brightness asymmetry. For the experimentally more relevant case of perfect prior knowledge of the pair's brightness centroid, however, such QFI becomes dependent on the pair separation vector in a way that is controlled by the degree of its brightness asymmetry. This study yields potentially useful insights into the analysis of a more general superresolution imaging problem involving extended incoherent sources with nontrivial brightness distributions.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
Due to the wave nature of light, optical imaging is inherently subject to diffraction, which typically dictates the resolution limit for two-point sources. A practical way to describe this phenomenon is through Rayleigh’s criterion, which states that two sources are barely resolvable when the minimum of one source's diffraction pattern coincides with the maximum of the other. However, recent advances in optical quantum metrology have shown that this classical limit can be surpassed by leveraging the spatial correlations within the light field. Specifically, decomposing the light into a Hermite-Gauss mode basis provides substantially more information than traditional direct imaging, which measures local intensity [1,2,3]. In this work, we implement a spatial demultiplexing technique to estimate the separation between light sources of unequal brightness. This unknown imbalance adds complexity to the estimation task, making it inherently a multiparameter problem and thus requiring a multimode approach [4]. By optimizing the measurement strategy and introducing a shift between two demultiplexers, we achieve sub-Rayleigh resolution in distance measurements without assuming prior knowledge of the intensity imbalance or alignment. [1] Tsang, M., Nair, R., & Lu, X. M. (2016). Quantum theory of superresolution for two incoherent optical point sources. Physical Review X, 6(3), 031033. [2] Sorelli, G., Gessner, M., Walschaers, M., & Treps, N. (2021). Optimal observables and estimators for practical superresolution imaging. Physical Review Letters, 127(12), 123604. [3] Rouvière, C., Barral, D., Grateau, A., Karuseichyk, I., Sorelli, G., Walschaers, M., & Treps, N. (2024). Ultra-sensitive separation estimation of optical sources. Optica, 11(2), 166-170. [4] Řeháček, J., Hradil, Z., Koutný, D., Grover, J., Krzic, A., & Sánchez-Soto, L. L. (2018). Optimal measurements for quantum spatial superresolution. Physical review A, 98(1), 012103.
Interferometric methods have been recently investigated to achieve sub-Rayleigh imaging and precision measurements of faint incoherent sources up to the ultimate quantum limit. Here we consider single-photon imaging of two point-like emitters of unequal intensity. This is motivated by the fact that pairs of natural emitters typically have unequal brightness, for example, binary star systems and exoplanets. We address the problem of estimating the transverse separation d or the relative intensity . Our theoretical analysis shows that the associated statistical errors are qualitatively different from the case of equal intensity. We employ multi-plane light conversion technology to implement Hermite–Gaussian (HG) spatial-mode demultiplexing (SPADE), and demonstrate sub-Rayleigh measurement of two emitters with a Gaussian point-spread function. The experimental errors are comparable with the theoretical bounds. The latter are benchmarked against direct imaging, yielding an improvement in the signal-to-noise ratio, which may be significant when the primary source is much brighter than the secondary one, for example, as for imaging of exoplanets.
We analyze the ultimate quantum limit of resolving two identical sources in a noisy environment. We prove that in the presence of noise causing false excitation, such as thermal noise, the quantum Fisher information of arbitrary quantum states for the separation of the objects, which quantifies the resolution, always converges to zero as the separation goes to zero. Noisy cases contrast with noiseless cases where the quantum Fisher information has been shown to be nonzero for a small distance in various circumstances, revealing the superresolution. In addition, we show that false excitation on an arbitrary measurement, such as dark counts, also makes the classical Fisher information of the measurement approach to zero as the separation goes to zero. Finally, a practically relevant situation resolving two identical thermal sources is quantitatively investigated by using the quantum and classical Fisher information of finite spatial mode multiplexing, showing that the amount of noise poses a limit on the resolution in a noisy system.
The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.