Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Theoretical Investigations in Support of a Cold-Atom Based UHV Pressure Sensor

Constantinos Makrides, Eite Tiesinga

Published Jun 6, 2017• 0 citations
OpenAlex

Related papers

Non-Reactive Atom-Molecule Scattering in Support of a Cold-Atom Based UHV Pressure Sensor

Constantinos Makrides, Eite Tiesinga

Bulletin of the American Physical Society•May 29, 2018•0 citations

Advances in cold atom UHV/XHV metrology

Xiangmin Wu, Yongjun Cheng, Dong Meng +7 more

Vacuum•Oct 6, 2022•6 citations

Cold atom technology applied to ultra-high vacuum (UHV) measurements

Wenjun Sun, Xiangmin Wu, Yongjun Cheng +8 more

Vacuum•Feb 23, 2024•6 citations

Microstructured optical fiber UHV integration for cold-atom experiments

Jean‐François Clément, T. Vitse, Pascal Szriftgiser

Journal of Vacuum Science & Technology A Vacuum Surfaces and Films•Nov 1, 2010•1 citation

Challenges to miniaturizing cold atom technology for deployable vacuum metrology

Stephen Eckel, Daniel S. Barker, James A. Fedchak +5 more

Cold atoms are excellent metrological tools; they currently realize SI time and, soon, SI pressure in the ultra-high (UHV) and extreme high vacuum (XHV) regimes. The development of primary, vacuum metrology based on cold atoms currently falls under the purview of national metrology institutes. Under the emerging paradigm of the "quantum-SI", these technologies become deployable (relatively easy-to-use sensors that integrate with other vacuum chambers), providing a primary realization of the pascal in the UHV and XHV for the end-user. Here, we discuss the challenges that this goal presents. We investigate, for two different modes of operation, the expected corrections to the ideal cold-atom vacuum gauge and estimate the associated uncertainties. Finally, we discuss the appropriate choice of sensor atom, the light Li atom rather than the heavier Rb.

arXiv:1809.05378•Metrologia•Aug 21, 2018•51 citations

Pulsed loading of a magneto-optical trap on atom chip for fast pressure recovery in ultrahigh vacuum environment

Singh, Vivek, Vibhuti Bhushan Tiwari, A. Chaudhary +2 more

This study presents investigations on pulsed loading of a magneto-optical trap (MOT) on an atom chip in an UHV environment. Using three parallel resistively heated Rb-metal dispensers activated by pulsed current supply, approximately 3.0 $\times$ $10^{7}$ cold $^{87}Rb$ atoms were loaded into the MOT. A current pulse of $\sim$ 24 A with duration of $\sim$ 10 s raised the pressure in the chamber from 2.0 $\times$ $10^{-10}$ Torr to 3.3 $\times$ $10^{-10}$ Torr. Remarkably, the pressure recovery time after switching off the dispensers current was found to be $\sim$ 600 ms, making a significant advancement in achieving fast recovery of UHV environment surrounding the MOT region. This study is very useful for laser cooling and magnetic trapping / evaporative cooling of atoms on atom chip in the same UHV chamber.

arXiv:2403.11458•Mar 18, 2024•0 citations
Cold atoms are excellent metrological tools; they currently realize SI time and, soon, SI pressure in the ultra-high (UHV) and extreme high vacuum (XHV) regimes. The development of primary, vacuum metrology based on cold atoms currently falls under the purview of national metrology institutes. Under the emerging paradigm of the "quantum-SI", these technologies become deployable (relatively easy-to-use sensors that integrate with other vacuum chambers), providing a primary realization of the pascal in the UHV and XHV for the end-user. Here, we discuss the challenges that this goal presents. We investigate, for two different modes of operation, the expected corrections to the ideal cold-atom vacuum gauge and estimate the associated uncertainties. Finally, we discuss the appropriate choice of sensor atom, the light Li atom rather than the heavier Rb.
This study presents investigations on pulsed loading of a magneto-optical trap (MOT) on an atom chip in an UHV environment. Using three parallel resistively heated Rb-metal dispensers activated by pulsed current supply, approximately 3.0 ×\times× 10710^{7}107 cold 87Rb^{87}Rb87Rb atoms were loaded into the MOT. A current pulse of ∼\sim∼ 24 A with duration of ∼\sim∼ 10 s raised the pressure in the chamber from 2.0 ×\times× 10−1010^{-10}10−10 Torr to 3.3 ×\times× 10−1010^{-10}10−10 Torr. Remarkably, the pressure recovery time after switching off the dispensers current was found to be ∼\sim∼ 600 ms, making a significant advancement in achieving fast recovery of UHV environment surrounding the MOT region. This study is very useful for laser cooling and magnetic trapping / evaporative cooling of atoms on atom chip in the same UHV chamber.