Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cold-atoms: A clean system for clocks based on coherent population trapping (Conference Presentation)

Elizabeth A. Donley, Xiaochi Liu, Eugene N. Ivanov, Valeriy I. Yudin, John E. Kitching

Published Apr 28, 2017• 0 citations
Publisher

Abstract

A review of a cold-atom clock based on coherent population trapping that highlights recent progress will be presented. Improvements in the coherence of the interrogation spectrum have resulted in the generation of dark states in the cold Rb atoms with essentially 100 % transmission – evidence that decoherence in this system is negligible. This improvement in coherence has resulted in improved short-term stability at the level of 1.5E-11 fractional frequency stability for a one second integration period. In combination with improved interrogation schemes, the improved spectrum has also resulted in dramatically smaller light shifts and improved long-term frequency stability – with the clock averaging down to the level of 1E-13 fractional frequency stability on time scales of over 10,000 seconds.

DOI
10.1117/12.2261162

Related papers

Light shifts in a pulsed cold-atom coherent-population-trapping clock

E. Blanshan, Simon Rochester, Elizabeth A. Donley +1 more

Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in applications ranging from network synchronization to inertial navigation. A coherent-population-trapping clock featuring laser-cooled $^{87}\mathrm{Rb}$ atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the frequency biases can be minimized and controlled. Here we characterize the light shift in a cold-atom coherent-population-trapping clock, explaining observed shifts in terms of phase shifts that arise during the formation of dark-state coherences combined with optical-pumping effects caused by unwanted incoherent light in the interrogation spectrum. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that would reduce clock frequency uncertainty from light shifts to a fractional frequency level of $\ensuremath{\Delta}\ensuremath{\nu}/\ensuremath{\nu}=4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ per 100 kHz of laser frequency uncertainty.

Physical Review A•Apr 10, 2015•42 citations

Frequency biases in a cold-atom coherent population trapping clock

Elizabeth A. Donley, E. Blanshan, François-Xavier Esnault +1 more

A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

Cold-atom double- Λ coherent population trapping clock

François-Xavier Esnault, E. Blanshan, Eugene N. Ivanov +3 more

Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on ${}^{87}$Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.

Physical Review A•Oct 31, 2013•83 citations

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan +3 more

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

Chinese Physics B•Oct 6, 2021•8 citations

Systematic shifts in chip-scale atomic beam clocks

Gabriela D. Martinez, Alexander L. Staron, John E. Kitching +2 more

We report on progress in the characterization of systematic shifts in chip-scale atomic beam clocks, which offer the potential for improved long-term stability relative to existing chip-scale atomic clocks. Previous work has demonstrated the key features of chip-scale atomic beam devices including the use of a microfabricated Si/glass atomic beam cell, passively maintained vacuum environment, and an integrated Rb atomic beam source. A beam clock has been realized using Ramsey coherent population trapping interrogation with a demonstrated short-term fractional frequency stability of ≈ 1.2 × 10^(-9)at 1 s of integration. In this talk, we discuss the path toward long-term stabilty in chip-scale atomic beam clocks and leading clock systematics. Chip-scale atomic beams are a new platform for quantum sensing which offer the potential for long-term stability in compact, low-power applications.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Toward a High-Stability Coherent Population Trapping Cs Vapor-Cell Atomic Clock Using Autobalanced Ramsey Spectroscopy

Moustafa Abdel Hafiz, Grégoire Coget, Michael Petersen +5 more

The next generation of alkali-vapor-cell atomic clocks are under development in labs around the world, with prototypes already demonstrating short-term fractional frequency stabilities one or two orders of magnitude better than for commercial clocks. However, stability is often spoiled at medium time scales (>100 s) by light-power-induced frequency-shift effects. The authors tackle this problem by applying autobalanced Ramsey interrogation, recently demonstrated on a Yb${}^{+}$ clock, to coherent-population-trapping systems---an approach that could really boost the development of vapor-cell clocks with white-noise-limited frequency stability over greatly extended time scales.

Physical Review Applied•Jun 1, 2018•66 citations
A review of a cold-atom clock based on coherent population trapping that highlights recent progress will be presented. Improvements in the coherence of the interrogation spectrum have resulted in the generation of dark states in the cold Rb atoms with essentially 100 % transmission – evidence that decoherence in this system is negligible. This improvement in coherence has resulted in improved short-term stability at the level of 1.5E-11 fractional frequency stability for a one second integration period. In combination with improved interrogation schemes, the improved spectrum has also resulted in dramatically smaller light shifts and improved long-term frequency stability – with the clock averaging down to the level of 1E-13 fractional frequency stability on time scales of over 10,000 seconds.
Field-grade atomic clocks capable of primary standard performance in compact physics packages would be of significant value in applications ranging from network synchronization to inertial navigation. A coherent-population-trapping clock featuring laser-cooled 87Rb^{87}\mathrm{Rb}87Rb atoms and pulsed Ramsey interrogation is a strong candidate for this technology if the frequency biases can be minimized and controlled. Here we characterize the light shift in a cold-atom coherent-population-trapping clock, explaining observed shifts in terms of phase shifts that arise during the formation of dark-state coherences combined with optical-pumping effects caused by unwanted incoherent light in the interrogation spectrum. Measurements are compared with existing and new theoretical treatments, and a laser configuration is identified that would reduce clock frequency uncertainty from light shifts to a fractional frequency level of $\ensuremath{\Delta}\ensuremath{\nu}/\ensuremath{\nu}=4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ per 100 kHz of laser frequency uncertainty.
A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.
Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on 87{}^{87}87Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.
We report on progress in the characterization of systematic shifts in chip-scale atomic beam clocks, which offer the potential for improved long-term stability relative to existing chip-scale atomic clocks. Previous work has demonstrated the key features of chip-scale atomic beam devices including the use of a microfabricated Si/glass atomic beam cell, passively maintained vacuum environment, and an integrated Rb atomic beam source. A beam clock has been realized using Ramsey coherent population trapping interrogation with a demonstrated short-term fractional frequency stability of ≈ 1.2 × 10^(-9)at 1 s of integration. In this talk, we discuss the path toward long-term stabilty in chip-scale atomic beam clocks and leading clock systematics. Chip-scale atomic beams are a new platform for quantum sensing which offer the potential for long-term stability in compact, low-power applications.
The next generation of alkali-vapor-cell atomic clocks are under development in labs around the world, with prototypes already demonstrating short-term fractional frequency stabilities one or two orders of magnitude better than for commercial clocks. However, stability is often spoiled at medium time scales (>100 s) by light-power-induced frequency-shift effects. The authors tackle this problem by applying autobalanced Ramsey interrogation, recently demonstrated on a Yb+{}^{+}+ clock, to coherent-population-trapping systems---an approach that could really boost the development of vapor-cell clocks with white-noise-limited frequency stability over greatly extended time scales.