Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Precision phase estimation based on weak-value amplification

Xiaodong Qiu, Linguo Xie, Xiong Liu, Lan E Luo, Zhaoxue Li, Zhiyou Zhang, Jinglei Du

Published Feb 13, 2017• 104 citations
Publisher

Abstract

In this letter, we propose a precision method for phase estimation based on the weak-value amplification (WVA) technique using a monochromatic light source. The anomalous WVA significantly suppresses the technical noise with respect to the intensity difference signal induced by the phase delay when the post-selection procedure comes into play. The phase measured precision of this method is proportional to the weak-value of a polarization operator in the experimental range. Our results compete well with the wide spectrum light phase weak measurements and outperform the standard homodyne phase detection technique.

DOI
10.1063/1.4976312

Related papers

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance

Jing-Hui Huang, Xiang-Yun Hu

We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of $T$ = $0.01-0.1$ s, representing two orders of magnitude variance reduction compared to the $T=300$ s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number $1/N_r$, confirming shot-noise-limited operation with WVA. Furthermore, this $1/N_r$ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime ($>10$ Hz).

quant-pharXiv:2602.17035•Physical Review A•Feb 20, 2026•6 citations

Can Anomalous Amplification be Attained without Postselection?

Julián Martínez-Rincón, Wei-Tao Liu, Gerardo I. Viza +1 more

We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.

arXiv:1509.04810•Physical Review Letters•Mar 9, 2016•44 citations

Weak Value Amplification of a Post-Selected Single Photon

Matin Hallaji

Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.

•Jun 1, 2016•3 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•19 citations

基于多重弱相互作用的增强型相位弱测量

张建超 Zhang Jianchao, 郭晓敏 Guo Xiaomin, 侯佳慧 Hou Jiahui +2 more

Objective Quantum weak measurement is a measurement technique based on minimal intrusion and the weak value amplification (WVA) effect, which significantly expands the capability of quantum precision measurement. Quantum weak measurements have been applied to tiny-phase measurements and have yielded a series of results. Previous standard weak measurements primarily used spectral or CCD pointers to achieve precise measurements of tiny phases under a single weak interaction (SWI). However, a trade-off between enhancing the amplification factor (known as the anomalous weak value) and the post-selection probability is encountered in SWIs. Because of the difficulty in enhancing both simultaneously, the extraction of the anomalous weak value and the measurement precision are limited. This issue is typically alleviated using quantum resources. However, difficulties in preparing quantum resources restrict their practical applications. Hence, practical quantum weak measurement systems must be further investigated to overcome these limitations. Methods In this study, an enhanced phase weak measurement method based on multiple weak interactions (MWIs) is proposed and demonstrated. The evolution of the intensity pointer was analyzed theoretically and a formulation for enhanced WVA was derived. A system for enhanced phase weak measurements based on MWIs was constructed using continuous coherent light as the incident source. This setup employs double weak interactions with two sets of half-wave plates (HWPs) as well as an avalanche photodiode (APD) as the intensity pointer. The post-selection angle was fixed, and the HWP was tilted to introduce a weak phase delay for the measurement. Meanwhile, the phase delay was detected precisely by recording changes in the light intensity. By maintaining a constant phase delay and adjusting the post-selection angle, anomalously weak values were extracted with a high signal-to-noise ratio (SNR). Results and Discussions Owing to the double weak interactions, the intensity shift is greater than that resulted under the SWI (Fig. 4). The symmetrical post-selection intensity contrast ratios exceed those under the SWI by approximately two folds (Fig. 5), thus indicating that the double-weak-interaction scheme offers a higher measurement sensitivity. At three post-selection angles of 0.002, 0.004, and 0.007 rad, the intensity uncertainties of the double weak interactions are 0.006, 0.015, and 0.040 mV, respectively (Fig. 6), and the phase precisions are 6.00×10-7, 7.76×10-7, and 9.46×10-7 rad, respectively. Compared with the SWI, the double weak interactions improved the phase precision by approximately an order of magnitude. Under the double weak interactions, an anomalously weak value of 239 is obtained with a high SNR of 18.2 dB for a post-selection angle of 0.0084 rad. Decreasing the post-selection angle to 0.002 rad while the SNR remains at 9.8 dB results in a higher anomalous weak value of 993 (Fig. 7). Conclusions In this study, based on the amplification effect of anomalous weak values on the interaction parameters, an enhanced WVA scheme based on MWIs was theoretically and experimentally demonstrated and applied to ultraprecise phase measurements. Experimentally, coherent light with a linewidth of 400 kHz was used as the incident light source and an APD was utilized as the intensity pointer, which is different from previous spectral detection schemes. By developing the MWI theory and experimental scheme as well as realizing double weak interaction (N=2) measurements, the experimental results show that the phase measurement sensitivity is significantly better than that achieved under SWIs. In particular, an optimal measurement precision of 6.0×10-7 rad is achieved at a post-selection angle of 0.002 rad, which is approximately an order of magnitude higher than that achieved under an SWI. Additionally, based on a high SNR of 9.8 dB at a post-selection angle of 0.002 rad, an enhanced anomalous weak value of 993 is measured, which is approximately an order of magnitude greater than the standard weak measurement. The enhanced WVA scheme based on MWIs was validated via phase measurements, whereas the relationship between the phase and other physical quantities, such as displacement, temperature, and magnetic induction strength, can be established in optical experiments; thus, the scheme provides important technical support for practical enhanced quantum precision sensing.

Chinese Journal of Lasers•Jan 1, 2025•2 citations
In this letter, we propose a precision method for phase estimation based on the weak-value amplification (WVA) technique using a monochromatic light source. The anomalous WVA significantly suppresses the technical noise with respect to the intensity difference signal induced by the phase delay when the post-selection procedure comes into play. The phase measured precision of this method is proportional to the weak-value of a polarization operator in the experimental range. Our results compete well with the wide spectrum light phase weak measurements and outperform the standard homodyne phase detection technique.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of TTT = 0.01−0.10.01-0.10.01−0.1 s, representing two orders of magnitude variance reduction compared to the T=300T=300T=300 s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number 1/Nr1/N_r1/Nr​, confirming shot-noise-limited operation with WVA. Furthermore, this 1/Nr1/N_r1/Nr​ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime (>10>10>10 Hz).
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.
Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
Objective Quantum weak measurement is a measurement technique based on minimal intrusion and the weak value amplification (WVA) effect, which significantly expands the capability of quantum precision measurement. Quantum weak measurements have been applied to tiny-phase measurements and have yielded a series of results. Previous standard weak measurements primarily used spectral or CCD pointers to achieve precise measurements of tiny phases under a single weak interaction (SWI). However, a trade-off between enhancing the amplification factor (known as the anomalous weak value) and the post-selection probability is encountered in SWIs. Because of the difficulty in enhancing both simultaneously, the extraction of the anomalous weak value and the measurement precision are limited. This issue is typically alleviated using quantum resources. However, difficulties in preparing quantum resources restrict their practical applications. Hence, practical quantum weak measurement systems must be further investigated to overcome these limitations. Methods In this study, an enhanced phase weak measurement method based on multiple weak interactions (MWIs) is proposed and demonstrated. The evolution of the intensity pointer was analyzed theoretically and a formulation for enhanced WVA was derived. A system for enhanced phase weak measurements based on MWIs was constructed using continuous coherent light as the incident source. This setup employs double weak interactions with two sets of half-wave plates (HWPs) as well as an avalanche photodiode (APD) as the intensity pointer. The post-selection angle was fixed, and the HWP was tilted to introduce a weak phase delay for the measurement. Meanwhile, the phase delay was detected precisely by recording changes in the light intensity. By maintaining a constant phase delay and adjusting the post-selection angle, anomalously weak values were extracted with a high signal-to-noise ratio (SNR). Results and Discussions Owing to the double weak interactions, the intensity shift is greater than that resulted under the SWI (Fig. 4). The symmetrical post-selection intensity contrast ratios exceed those under the SWI by approximately two folds (Fig. 5), thus indicating that the double-weak-interaction scheme offers a higher measurement sensitivity. At three post-selection angles of 0.002, 0.004, and 0.007 rad, the intensity uncertainties of the double weak interactions are 0.006, 0.015, and 0.040 mV, respectively (Fig. 6), and the phase precisions are 6.00×10-7, 7.76×10-7, and 9.46×10-7 rad, respectively. Compared with the SWI, the double weak interactions improved the phase precision by approximately an order of magnitude. Under the double weak interactions, an anomalously weak value of 239 is obtained with a high SNR of 18.2 dB for a post-selection angle of 0.0084 rad. Decreasing the post-selection angle to 0.002 rad while the SNR remains at 9.8 dB results in a higher anomalous weak value of 993 (Fig. 7). Conclusions In this study, based on the amplification effect of anomalous weak values on the interaction parameters, an enhanced WVA scheme based on MWIs was theoretically and experimentally demonstrated and applied to ultraprecise phase measurements. Experimentally, coherent light with a linewidth of 400 kHz was used as the incident light source and an APD was utilized as the intensity pointer, which is different from previous spectral detection schemes. By developing the MWI theory and experimental scheme as well as realizing double weak interaction (N=2) measurements, the experimental results show that the phase measurement sensitivity is significantly better than that achieved under SWIs. In particular, an optimal measurement precision of 6.0×10-7 rad is achieved at a post-selection angle of 0.002 rad, which is approximately an order of magnitude higher than that achieved under an SWI. Additionally, based on a high SNR of 9.8 dB at a post-selection angle of 0.002 rad, an enhanced anomalous weak value of 993 is measured, which is approximately an order of magnitude greater than the standard weak measurement. The enhanced WVA scheme based on MWIs was validated via phase measurements, whereas the relationship between the phase and other physical quantities, such as displacement, temperature, and magnetic induction strength, can be established in optical experiments; thus, the scheme provides important technical support for practical enhanced quantum precision sensing.