Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1509.04810 · Physical Review Letters

Can Anomalous Amplification be Attained without Postselection?

Julián Martínez-Rincón, Wei-Tao Liu, Gerardo I. Viza, John C. Howell

Published Mar 9, 2016• 39 citations
arXivHTMLPDF

Abstract

We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.

DOI
10.1103/physrevlett.116.100803

Related papers

Entanglement-Assisted Weak Value Amplification

Shengshi Pang, Justin Dressel, Todd A. Brun

Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.

arXiv:1401.5887•Physical Review Letters•Jul 15, 2014•107 citations

Achieving metrological precision limits through postselection

G. B. Alves, Arthur Pimentel, Malena O. Hor-Meyll +3 more

Postselection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different postselection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method that does not provide amplification but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cram\'er-Rao bound. For both situations, we show that parameter estimation is improved when the postselection statistics are considered together with the measurement device.

arXiv:1606.03478•Physical Review A•Jan 6, 2017•16 citations

Weak value amplification for nonunitary evolution

Wei-Tao Liu, Julián Martínez-Rincón, John C. Howell

We discuss interferometric parameter estimation of the amplitude, instead of the phase, via weak value amplification. The considered weak interaction introduces modulation on the amplitude of the wave function; therefore, the two-party state experiences a nonunitary evolution. With the same pre- and postselection states as those of original weak value amplification, a much larger anomalous amplification factor can be attained. The shift in the intensity profile at the dark port and the signal-to-noise ratio for the parameter of interest get further amplified by the weak value, compared to phase-based weak value amplification. Although the nonunitary evolution introduces loss, more information about the parameter of interest can be extracted. Thus the weak value amplification is extended to measurement of amplitude and nonunitary processes. We also discuss possible applications of this idea for precisely measuring tiny rotations or enhancing the image contrast of transparent objects.

Physical Review A•Jul 23, 2019•5 citations

Precision phase estimation based on weak-value amplification

Xiaodong Qiu, Linguo Xie, Xiong Liu +4 more

In this letter, we propose a precision method for phase estimation based on the weak-value amplification (WVA) technique using a monochromatic light source. The anomalous WVA significantly suppresses the technical noise with respect to the intensity difference signal induced by the phase delay when the post-selection procedure comes into play. The phase measured precision of this method is proportional to the weak-value of a polarization operator in the experimental range. Our results compete well with the wide spectrum light phase weak measurements and outperform the standard homodyne phase detection technique.

Applied Physics Letters•Feb 13, 2017•99 citations

Weak Value Amplification is Suboptimal for Estimation and Detection

Christopher Ferrie, Joshua Combes

We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

arXiv:1307.4016•Physical Review Letters•Jan 31, 2014•213 citations

Estimation of an optomechanical parameter via weak-value amplification

Sergio Carrasco, Miguel Orszag

In this article we present an experimental proposal for the estimation of an optomechanical parameter in the presence of noise. The estimation is based on the technique of weak-value amplification which can enlarge the radiation pressure effect of a single photon on a mechanical oscillator. In our setup we show that the weak-value amplification technique is preferable for the estimation over a method that relies on a strong measurement with postselection because the first method does not require a good prior knowledge of the parameter we wish to estimate, while both strategies reach the same level of precision from a Fisher information perspective. In the presence of strongly correlated noise, the weak-value amplification method is preferable, from a Fisher information perspective, than a standard measurement strategy that does not employ postselection and that is affected by the same type of noise.

arXiv:1902.09247•Physical Review A•Apr 11, 2022•6 citations
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.
Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.
Postselection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different postselection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method that does not provide amplification but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cram\'er-Rao bound. For both situations, we show that parameter estimation is improved when the postselection statistics are considered together with the measurement device.
We discuss interferometric parameter estimation of the amplitude, instead of the phase, via weak value amplification. The considered weak interaction introduces modulation on the amplitude of the wave function; therefore, the two-party state experiences a nonunitary evolution. With the same pre- and postselection states as those of original weak value amplification, a much larger anomalous amplification factor can be attained. The shift in the intensity profile at the dark port and the signal-to-noise ratio for the parameter of interest get further amplified by the weak value, compared to phase-based weak value amplification. Although the nonunitary evolution introduces loss, more information about the parameter of interest can be extracted. Thus the weak value amplification is extended to measurement of amplitude and nonunitary processes. We also discuss possible applications of this idea for precisely measuring tiny rotations or enhancing the image contrast of transparent objects.
In this letter, we propose a precision method for phase estimation based on the weak-value amplification (WVA) technique using a monochromatic light source. The anomalous WVA significantly suppresses the technical noise with respect to the intensity difference signal induced by the phase delay when the post-selection procedure comes into play. The phase measured precision of this method is proportional to the weak-value of a polarization operator in the experimental range. Our results compete well with the wide spectrum light phase weak measurements and outperform the standard homodyne phase detection technique.
We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
In this article we present an experimental proposal for the estimation of an optomechanical parameter in the presence of noise. The estimation is based on the technique of weak-value amplification which can enlarge the radiation pressure effect of a single photon on a mechanical oscillator. In our setup we show that the weak-value amplification technique is preferable for the estimation over a method that relies on a strong measurement with postselection because the first method does not require a good prior knowledge of the parameter we wish to estimate, while both strategies reach the same level of precision from a Fisher information perspective. In the presence of strongly correlated noise, the weak-value amplification method is preferable, from a Fisher information perspective, than a standard measurement strategy that does not employ postselection and that is affected by the same type of noise.